자체 개발한 하악거상 기구를 활용한 소아 REVERS WATER'S View의 유용성
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 15 Number 2 2013.11 pp.1-6
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
This study is to provide clinical data when reverse-water's-view was carried out about pediatric who did not communicate by applying self-development jaw lift tool. This study were conducted in a subject of 23 children who examined revers-water's-view from 2013 July 6 to 2013 August 5 at our hospital. Two group time which were carried out revers-water's with tool and without tool were measured. also, Image of two group were evaluated. Evaluation data obtained by measuring the average difference were analyzed by independent-t-test. After apply self-development-jaw-lift-tool, time was reduced by 35.2%(36.6sec). the results indicated significant differences(p<.05). Image evaluation was increase 43.5%(1.03point), It was statistically highly significant difference (p<.01). If apply self-development-jaw-lift-tool in pediatric revers-water's-view, operator can provide fast, convenience, high quality image to pediatric.
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 15 Number 2 2013.11 pp.7-11
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
Purpose: This study was to evaluate effectiveness of the modified position in scapular AP (anterioposterior) projection. Materials and Methods: From June 2012 to July 2013, scapular AP projection was examined in 108 patients by use of conventional method and in 40 patients by use of modified method. We compared between conventional method and modified method following variables including sex, age, height, weight, and BMI. We measured and compared distance between lateral border of the scapular and the rib to confirm the separation of the scapular from the lung fields including the ribs. Results: The scapular AP projection was technically successful in all patients. There was no significant difference in patient characteristics including sex, age, height, weight, and BMI between conventional method and modified method. The mean distance between lateral border of the scapular and rib in conventional method and modified method was 15.09 mm and 26.33 mm, respectively. Modified method was significantly increased the distance between lateral border of the scapular and rib compared with conventional method (P < .01). Conclusion: The modified position in scapular AP projection was effective method to separate between the scapular and lung fields including the ribs compared with conventional position of scapular AP projection.
투시 검사 시 장비에 따른 환자와 시술자의 입사표면선량 연구
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 15 Number 2 2013.11 pp.13-18
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
Purpose : Fluoroscopy equipment, depending on the type of changes that occur in the patient's position ESD and study the patient's scatter ray of ESD Practitioners considered a comparative analysis was to evaluate the correct dose. Materials and Methods : HITACHI four overtube type TU-8000 Flat Detector and Under tube C-Arm Philips' Multi Diagnost Eleva with Flat Detector type were measured by. Each devices is a measure of the patient's esd randophantom position in tabel unfors Xi multi funtion then fixed to the abdomen fluoroscopy and 10 seconds, spot was measured three times, practitioners of the incident surface dose by considering the patient's scatter ray of the table for each device in the average human stomach 21cm thickness acrylic phantom (25 cm × 25 cm) Place the practitioner position after position randophantom unfors Xi multi funtion in the thyroid and stomach 1 minute by a fixed one-time fluoroscopy and measured. Results : 10 seconds and the patient perspective of the c-arm ESD 1.2 times smaller on the AP and oblique measurements were measured in the 6-13 times smaller. spot positions to changes in the measured three times on the AP of the abdomen, ESD is 18 times smaller c-arm measurements and the oblique measurement was 19-30 times smaller. And 1 minute at practitioners fluoroscopy esd in the thyroid 2.12 times the c-arm, chest 1.75 times less the dose was measured. On the AP, depending on the device, but the lack of dose difference oblique positions of the two devices depending on changes in the area due to changes in both the AP than on the dose increased, the difference in dose between the two devices, the maximum difference was approximately 27 times. Conclusion : Fluoroscopic equipment at the time of inspection in accordance with changes in dose according to the patient and the patient's positions changes, because the area of the scatter ray considering the change of dose measurements be made, and study of the equipment according to the characteristics of the efficiency and the exposure of the patient and practitioner is considered smooth study equipment manufacturers that can be done is to build the system and think that is also important. Various fluoroscopy when you check future changes in many factors of change in dose for the equipment in the laboratory system by considering the scatter ray radiation shielding for the management to take advantage of reckless undertube have been utilized as more exposure Reduction activities can help is considered as the direction.
가임기 여성의 유방촬영에서 Dose mode 적용의 유용성 분석
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 15 Number 2 2013.11 pp.19-23
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
Purpose : Automatic exposure system(AOP mode) in DR Mammography of the STD and DOSE apply to women of childbearing age, the average glandular dose(AGD) and image quality by comparing was to demonstrate the usefulness of DOSE. Materials and Methods : Of the under 40 age 108 patients who visit to our hospital and examined STD and DOSE mammography from January 2008 to July 2013. AGD was obtained by DICOM header information provided by GE Senographe DS. STD and DOSE images were evaluated with obtained patients, Image J program was compared by calculating the SNR. Results : The average AGD of DOSE mode was 0.99mGy, and which decreased by 19% comparing to that of STD mode which was 1.18mGy. The two the average AGDs indicated statistically significant difference(p<.01). The average SNR of STD was 40.26, DOSE displayed, and to 39.68 in, there was no statistical significance. Results : The average AGD using DOSE mode which is one of DR mammography AOP modes decreased by comparing to that of STD mode showing no difference in image quality. The use of DOSE is considered to be useful.
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 15 Number 2 2013.11 pp.25-30
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
The purpose of this study was to provide information about exhibits for nuclear energy in science museums. This analysed form and content of exhibits of science museums. The subjects were exhibits of 3 science museums; Seoul science park, Seoul national science museum, Gwachen national science museum. The research results were as follows: First, 3 science museums had similar methods of exhibits and types of explanations because of speciality of theme. 3 science museums had mostly fixed exhibit. Panel was the most types of explanations in 3 science museums. Second, 3 science museums had similar contents of exhibits. They dealt with nuclear power generation and radiation. However, Some parts such as radioactive waste, nuclear fusion generation had different. This study suggests that exhibits for nuclear energy of science museums use a variety of methods and types of explanation. Also, science museums need to increase exhibits for nuclear energy.
족부전후방향 체중부하 촬영 시 적정 입사각에 관한 연구
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 15 Number 2 2013.11 pp.31-37
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
Incident X-ray angles of weight bearing foot AP radiography which differ in each medical institution were compared. Optimal angles were derived from the study and suggested as basic data for clinical application. 19 patients with no abnormality on right foot took part in the study from June 2013 to July 2013. Weight bearing foot AP radiography in the correct position was examined with the incident X-ray angles of 10°, 15°, 20°, 25°, 30°, and 35°. All the images were evaluated subjectively by 5 radiological technologists of over 15 year work experience using Likert scale as 1 for ‘very poor’, 2 for ‘poor’, 3 for ‘fair’, 4 for ‘good’, 5 for ‘very good’, 6 for ‘excellent’, and analyzed with ANOVA and Scheffe. Image quality was the most optimal at 20°as 4.53, and relatively good at 25°as 4.38 and at 30°as 4.18. 35°and 10°were relatively poor. The average points of 6 groups indicated statistically significant difference (p<.01). In the post-mortem, 3 subgroups showed no statistically significant difference, and the average point of the groups of 20°, 25°, 30°was evaluated relatively higher than the other 2 groups. An optimal incident X-ray angle within the range from 20°to 30°for weight bearing foot AP radiography could make it possible to obtain the image of high diagnostic value and would be useful for clinical application in the future.
투시 조영 검사 시 확대율에 따른 피폭선량에 관한 고찰
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 15 Number 2 2013.11 pp.39-44
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
Purpose : The purpose of this study is the magnification rates depending on the area of patient dose (DAP) and glass dosimeter see the change of the dose according to the dose characteristics of low-magnification aims to raise standards. Materials and Method : Direct DR equipment Sonialvision DAR-8000f, Shimadzu was used, the patient entrance dose measurements to the surface of the Rando Phantom of the neck and the abdomen was placed on the Xi unfors. glass dosimeter for measuring organ doses at the same time the Rando Phantom of the major organs in place by inserting a 9 ", 12", 15 ", 17" and 30 seconds for each magnification were measured according in fluoroscopy. DAP meter area of the patient dose was measured. Result : Esophagography at 17" 143% than 9"magnification the average area dose was increased. Organ dose of Esophagography at 17" was decreased 25.32% than 9" magnification. UGI at 17" was increased 129.73% DAP than 9" magnification. Organ dose of UGI at 17" was decreased 23.32% than 9" magnification. Where the major organs of magnification at 17" were decreased(lung -25.96%, stomach -33.09%, spleen -27.81%, liver -4.92%) than 9" magnification. Conclusion : Expected to get better quality image While using the proper magnification, and have recognition that difference Organ doses and DAP meter in fluoroscopy
하지동맥조영 전산화단층촬영에서 자동선량 조절장치를 이용한 환자선량 감소 연구
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 15 Number 2 2013.11 pp.45-53
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
Purpose : Fixed way of mAs previously Low Extremity Computed Tomography Angiography(LECTA) examination were used. Automatic Current Selection(ACS) to use for the purpose of reducing the dose when Low Extremity Computed Tomography Angiography examining patients. Materials and methods : Were analyzed from July 2011 to July 2012 MDCT examination of Dose Length Product(DLP) LECTA 116 Case. It was defined as previous inspection methods(Old protocol). CT workstation is set to 100 mAs and 150 mAs protocol based on the patient's weight 70kg examined by LECTA. We defined as 'New protocol' that applies to ACS. The data collection period are 76 cases from October 2012 to January 2013 Results : 1. Average Total DLP of ’ Old protocol’ is 3602.943 mGy*cm. 2. Average Total DLP of ’ New protocol’ is 1762.977 mGy*cm. 3. Due to the 'New Protocol' use of Total DLP was reduced by approximately 51 %. Phase-specific dose reduction is as follows. Pre(33.62 %), Artery(64.63 %), Delay(49.0 %) 4. Using One way ANOVA Analysis of fluctuations obtained DLP is as follows. ‘Old protocol’, ’New protocol’ a value of P <0.001, P = 0.882 values were obtained. Conclusions : Dose reduction of 51 % is a useful study that proves. The results obtained using the ACS, the effects of a dose reduction of 51 % was obtained. Therefore, it has been proven to be a useful way. Statistics using SPSS version came out of the 'Old protocol' P-value P <0.0001. This result means that the DLP a large difference values. On the other hand, The results of the 'New protocol' was P = 0.882. These results means to that small and regularly was fluctuations of the dose. The use of ACS, you can get a reduction of the dose and will able to get the effect of reducing the dose errors.
고속스핀에코기법을 이용한 MRI검사에서 ETL 변화에 따른 영상 blurring의 평가
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 15 Number 2 2013.11 pp.55-61
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
The purpose of this study is to evaluate image blurring according to variation of the ETL and propose the clinically appropriate ETL range. SIEMENS MAGNETOM Skyra 3.0T and 20 channel head coil were used for the study. MRI phantom was kept the lines horizontally to three direction(X,Y,Z) of the coil and T1, T2 weighted images that used the fast spin echo technique acquired. The ETL with increase of 10 was applied from 10 to 80. In addition, the ETL with increase of 1 was applied in the interval statistically significant differences occurred. And T1, T2 weighted images that used the conventional spin echo technique acquired to compare image blurring of the images that used the fast spin echo technique. The slope of lattice in the images was measured using Image J 1.47v program to evaluate image blurring. And image blurring was determined by the degree of the slope. The statistical significance of both techniques was evaluated by the Kruskal-Wallis test of the SPSS 17.0v. And the correlation of the ETL and image blurring was evaluated quantitatively by regression analysis. The slope of the T1, T2 weighted images that used fast spin echo technique decreased as contrasted with conventional spin echo technique. In the result of the Kruskal-Wallis test, the T1, T2 weighted images that used fast spin echo technique made a significant difference with conventional spin echo technique. Particularly, in the Tomhane’ T2 test, the T1, T2 weighted images made a significant difference from ETL 22 and 31 respectively. In the result of the regression analysis, the R-squared of the T1, T2 weighted images are 0.762 and 0.793. It is difficult to apply the long ETL in the T1 weighted image caused by the short TR and multi-slices study. Therefore, clinical impact according to variation of the ETL is very slight in the T1 weighted images. But the application of the proper ETL is demanded in T2 weighted images using the fast spin echo technique in order to prevent image blurring.
3.0T MRI에서 온도변화가 T1 및 T2 이완시간에 미치는 영향
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 15 Number 2 2013.11 pp.63-68
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
Purpose : The relaxation times of tissue in MRI depend on strength of magnetic field, morphology of nuclear, viscosity, size of molecules and temperature. This study intended to analyze quantitatively that materials’ temperatures have effects on T1 and T2 relaxation times without changing of other conditions. Materials and Methods : The equipment was used MAGNETOM SKYRA of 3.0T(SIEMENS, Erlagen, Germany), 32 channel spine coil and Gd-DTPA water concentration phantom. To find out T1 relaxation time, Inversion Recovery Spin Echo sequences were used at 50, 400, 1100, 2500 ms of TI. To find out T2 relaxation time, Multi Echo Spin Echo sequences were used at 30, 60, 90, 120, 150, 180, 210, 240, 270 ms of TE. This experiment was scanned with 5 steps from 25 to 45°C. next, using MRmap(Messroghli, BMC Medical Imaging, 2012) T1 and T2 relaxation times were mapped. on the Piview STAR v5.0(Infinitt, Seoul, Korea) 5 steps were measured as the same ROI, and then mean values were calculated. Correlation between the temperatures and relaxation times were analyzed by SPSS(version 17.0, Chicago, IL, USA). Results : According to increase of temperatures, T1 relaxation times were 214.39±0.25, 236.02±0.87, 267.47±0.48, 299.44±0.64, 330.19±1.72 ㎳. T2 relaxation times were 180.17±0.27, 197.17±0.44, 217.92±0.39, 239.89±0.53, 257.40±1.77 ㎳. With the correlation analysis, the correlation coefficients of T1 and T2 relaxation times were statistically significant at 0.998 and 0.999 (p<0.05). Conclusion : T1 and T2 relaxation times are increased as temperature of tissue goes up. In conclusion, we suggest to recognize errors of relaxation time caused local temperature’s differences, and consider external factors as well in the quantitative analysis of relaxation time or clinical tests.
방사선 영상학 실습실 오염실태 조사 (D대학교 DR장비와 방사선 발생장치, Cassette 오염실태 조사)
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 15 Number 2 2013.11 pp.69-76
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
We checked the existence of bacteria at DR equipment, radiation generator and cassette in ‘D university’ to propose optimized management method for bacteria and disinfection at DR equipment, radiation generator and cassette at used in radiographic laboratory of the department of radiology. The infected region is treated by alcohol and cresol and compared before spraying and after spraying for 1, 3, 5 and 10 minutes. As time goes on, amount of bacteria colony decreases significantly. The Cresol is useful to disinfect the diminutive devices. However alcohol disinfection, at least 5 minutes later, and hand washing before practical training and shooting image is recommended due to the big and fixed radiography equipment which cause the soakage.