Volume 13 Number 2 (7건)
No

원저

1

4,000원

It is important to study using experimental animals for research about stroke. Magnetic Resonance Imaging(MRI) is avaluable diagnosticmethods for stroke diagnosis. The purpose of this research is to know the Magnetic Resonance Imaging(MRI) and histopathological characteristics findings after induction of photothrombotic cerebral infarction in rat brain. Male Sprague-Dawley rats were anesthetized, Rose Bengal dye(20 mg/kg) was intravenously injected. The right sensonrimotor cortex of rat brain was exposed to cold light of 7 mm diameter at a position of 1 mm anterior and 3.5 mm lateral to bregma for 20 min. The post-infarction effects were monitored by T1 weighted and T2 weighted images of brain MRI. Histopathological changes were observed after Hematoxylin & Eosin staining. The lesion appeared clearly high signal intensity area on T2 weighted images(the major axis 7.04±0.11 mm, the minor axis 3.08±0.04 mm) and also H&E staining was same result. In conclusion, MRI was avaluable diagnostic methods for diagnosis and serial changes of stroke.

2

양방사선 골밀도 측정 장치의 공간산란선량분포측정

김선칠, 원도연, 박창희, 동경래

대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 13 Number 2 2011.06 pp.59-62

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

In this experiment, how DEXA(Dual-energy X-ray Absorptiometry) bone mineral density was measured using the equipment. In order to maintain the same measurement conditions, bone mineral density measurements of 10 cm thick phantom, with an actual patient at a point when examining the same conditions(100 kVp, 1 mA) and then out to the five doses of radiation and its average was calculated by dividing measured. X-ray dose rate measured at the Research Institute, Sword of the gamma survey meters calibrated MEDCOM Ltd. (Inspector GM counter tube) was used, calibration factor is 1.15. On a horizontal plane around the patient, depending on the distance was significantly reduced dose rate. In addition, orientation 0° head end was higher in the direction of the highest dose rate, 0° 180° direction from the direction towards the higher dose rate reduced to some extent in the direction of all the 120° were able to identify.

3

4,000원

Table strapis patient fixture for securing the patient movements and falls. if it designed to measure the abdominal circumference and used as an indicator of dose selection at CT scan. it will prevent the overexposure of dose without degradation of image quality and efficiently manage dose of each type of body to technician to deal with CT. First, in order to compare the dose used in CT image and qualitative characteristics. reference image is obtained by examining the abdominal phantom in same conditions with the hospital 120 kVp, 200 mAs, D-Dom (Dynamic Dose Of Modulation). SNR, PSNR, RMSE, MAE, CTDIvol of CT images are compared with reference image. for comparing with reference image, the image that Umbilicus level image of Abdomen CT is stored in the PACS were used. For comparison, the top 12 o'clock portion of the air drawn from the same ROI was measured. CTDIvol, mAs, etc. In order to analyze the characteristics of the image, by measuring the length of the umbilicus circumference, pattern of the dose was analyzed. by using the analyzed perimeter and dose information, To be identified visually, fixed band that scale marked were produced. Use them, If the length of circumference of less than 60 cm 100 mAs, Case of 61~80 cm 120 mAs, Case of 80~100 cm 150 mAs, more than 100 cm 200 mAs, dose selection based on the perimeter, the image was applied. by compare analyzed with the Reference Image, image quality was assessed. by compare with existing tests that equally 200 mAs applied, How much was confirmed that the dose reduction. 1. Depending on the Abdominal circumference, the average PSNR(dB) of the image that differently dose applied was 45.794. 2. Comparing with existing test. the dose of scan that adjusted the mAs depending on the circumference was decreased about 40%. SNR and PSNR of the image that obtained by adjusting the standard mAs based on dose modulation were not much different. Therefore, By choosing a low mAs. dose reduction can be obtained. and the dose selection method that measured Abdominal circumference using a fixed band can protect the overexposure and uniformly apply dose of each type of body to technician to deal with CT

4

4,000원

Because interventional procedure operates looking at premier as real time when perate intervention enemy, by patient is revealed during suitableness time in radiation, side effect such as radiation injury of skin is apt to happen. It established by purpose of study that measure exposure dose that patient receives about these problem, and find solution for radiation injury and repletion method. In this study, we used Rando phantom of identical structure with the human body which becomes accomplished with 4 branch ingredient of the attempt and system equivalent material them and absorbed dose were measured by TLD. According to the laboratory, it shows that operations such as TFCA procedure or uterine myoma embolization are more dangerous than TACE procedure. If both operations are inspected during a short time, it is not affected in being bombed . However, it can lead to palliative agenesis or depilate, definitive agenesis only if operations are repeated more than three times. Dose distibution based on experiment, to reduce radiation exposure to patients result from reduction of scatter ray as we control field size of radiation and protection of side organs except for tumor. also we knew that we can protect patients form radiation exposure, if we increas SOD and decrease SID.

5

지역 의원 의료장비운영에 따른 적정성 평가

원도연, 김선칠, 박창희

대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 13 Number 2 2011.06 pp.77-81

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

Due to the increasing quantity of health services demand a wide range of growing medical markets and hospital through advanced, diversification can meet the needs of the patient. This hospital is having the introduction of expensive medical equipment. Because of this, hospitals are struggling to operate the hospital management. Therefore, when operating at the hospital before and after introduction of the most important factor in the interests of medical equipment through the analysis is directly related to hospital operations. CT study of the local clinics, or CR 40 where members of the medical equipment with 54 points against selected practitioners and hospital visits and interviews to investigate the expected benefits of each of the members raised an average of seven months to identify revenue performance caused by interests. Raised against the expected benefits resulting benefits to the overall average 87.43% did not meet the expected benefits. The hospital plans to introduce future when reviewing the medical equipment in consideration of the characteristics of the equipment requires a more solid plan, and whether the plan is properly implemented will be needed for the institutional verification capabilities.

6

Elliptical Centric과 TRICKS 기법의 임상 적용에 관한 유용성 연구

김새싹, 구은회, 동경래, 권대철, 이재승, 조재환, 박창희

대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 13 Number 2 2011.06 pp.83-90

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

To prospectively determine the diagnostic performance a combination of standard bolus-chase magnetic resonance (MR) angiography and MR angiography with time-resolved imaging of contrast kinetics (TRICKS) for depicting severity of the head and neck vascular diseases. Over a period of two months, A total of 100 patients(average ages : 50±8, male : 60, female : 40) with head and neck vascular diseases were performed on the GE excite 3.0 T units with 8-channel head coil and 4-channel NV coil. Imaging parameters for a typical study were as follow: SBC(TR/ TE/ FA/ SliceThicken./ Slab/ Freq./ FOV/ BW/ Scan Time) = 5.4/ min/ 30/ 2/ zip2/ 70/ 224x448/ 30/ 62.50/ 28, TRICKS(TR/ TE/ FA/ Slice Thicken/ Slab/ Freq./ FOV/ BW/ Temp Res./ Scan Time = 3.6/ min/ 25/ 4/ 30/ 160 x 384, zip512/ 30/ 100/ 1 to 1.5/ 23). The analysis of all MR images, which have respect-ively classified two techniques into some diseases. The results of the former were divided into two groups(SBC, TRICKS)with 4 grading of two reader, respectively. Wilcoxon signed rank test was used to determine if a significant difference between imaging techniques existed(p < 0.05). In 33 of 100 patients, arterio-venous malformation was 11% at TRICKS, subclavian vein stenosis : 8%, fistular sinus : 4%, jugular vein stenosis:6%, Middle Cerebral Artery bypass surgery : 4%, p < 0.05). The rest of 67 patients were considered as the results of SBC(14% in the basilar artery stenosis, carotid stenosis : 16%, vertebral stenosis : 17%, central neuro- cytoma : 5%, meningioma : 5%, Not appliable : 10%, p < 0.05). Sensitivity and specificity of TRICKS MR angiography in SVS, FS, JVS, MCABS were improved compared with those at standard MR angiography. In SBS MR angiography which were improved in BAS, CS, VS, CN, Meningioma. In conclusion, TRICKS MR angiography of the SVS, FS, JVS, MCABS is superior to standard MR angiography regarding the number of diagnostic grading. The SBS MR angiography were improved in BAS, CS, VS, CN, Meningioma. and assessment of the degree of luminal narrowing on both TRICKS and SBS.

7

4,000원

This study was conducted to know usefulness of panoramic radiography by comparing clinical evaluation and dental panoramic radiography in case of oral examination. Following results were concluded by analyzing difference between the result of Clinical evaluation and dental panoramic radiography. According to comparison the result of clinical evaluation and panoramic radiography, In Shin's research, dental caries was higher by 23.1%, periodontal disease was 31.9%, in An's research, dental caries was 24.2%. From new point of view from panoramic radiography, impacted tooth was 33.6%, Sinus abnormalities was 11.6%, periapical lesion was 5.4% in Shin's research and periapical lesion was 17.4%, 3rd molar impaction was 15.3% and retained root was 5.3% in An's research. Any kind of caries were not found in oral examination in the 66.7% of patients among patients with dental root caries in An's research. There were misdiagnose in oral examination(even side(59.5%),proximal side(59.5%), seconds caries(44.0%).

 