스마트폰을 이용한 ECG Viewer의 임상적 타당성 검토
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 12 Number 1 2010.05 pp.1-4
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
The study was designed to transmit ECG(electrocardiogram) images from iPhone in order to check validity. Especially, web examined ECG transmissions from smart phones image viewer are good enough to secure clinical information and confirmed with visual. In result, it took 3 to 5 seconds for ECG viewer transmitting from a smart phone to display an image on mobile server to user’s phone. For image valuation, we magnified the ECG image 100% or 200% at a resolution of 480 × 320 checking PQRST wave and found that it was both possible to see an accurate PQRST wave with all the trial data and to divide it into 1mm level of grid.
이동형 X선 장치 차폐도구 제작을 통한 표면선량 분포 측정
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 12 Number 1 2010.05 pp.5-8
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
Opened a court in February 10, 2006, a rule of safety management of the diagnosis radiation system was promulgated for safety of the radiation worker, patients and patients' family members. The purpose of this rule is to minimize the risk of being exposed to radiation during the process of handling X-ray. For this reason, we manufactured shielding device of mobile X-ray unit collimator for diminution of skin dose. Shielding device is made to a thickness of Pb 0.375mm. For portable chest radiography, we measured skin dose 50cm from center ray to 200cm at intervals of 20cm by Unfors Xi detector. As a result, a rule of safety management of the diagnosis radiation system has been strengthened. But there are exceptions, such as ER, OR, ICU to this rule. So shielding device could contribute to protect unnecessary radiation exposure and improve nation's health.
심뇌혈관 센터를 위한 Cardiac PACS의 도입과 적용 사례
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 12 Number 1 2010.05 pp.9-14
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
Based on the cardiac PACS application collected from three university hospitals across the country, this research showed us a composition method of a server and storage devices with conditions in the field. Also, we founded the practical use of software making the best of cardiovascular PACS features. In addition, it also examined the components and requirements of the key functions that are available in the cardiovascular sector. We will be investigated the design experience and applications on stable storage and transmission of large video clip data, cardiovascular analysis, and gear interlocks through the study.
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 12 Number 1 2010.05 pp.15-18
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
Main component of radiography barrier aprons is lead. To manufacture a lead-free barrier sheath, barium sulfate and organic iodine-based chemicals should be mixed with rubber. Barrier capacity was tested in the medical field. To improve adaptation of rubber with the mixture, raw materials went through milling, agitation, and extruding processes. Three sheaths were manufactured with 30%, 80%, and 120% sulfate barium, respectively. This study found 10% lower barrier capacity of lead-free barrier than the traditional lead-containing rubber sheath. Problems, however, were confronted during the agitation and extruding processes. Mixing with rubber was a technically demanding job. Inconsistent depth, problems with thermal processing and dissipation were encountered as well.
디지털 진단방사선촬영에서 부가여과판 사용에 따른 피폭선량 감소와 화질 개선
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 12 Number 1 2010.05 pp.19-25
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
This study is mainly for the reduction of exposure dose by using a heavy elements filter(Gd) in the digital radiology. They contained heavy elements filter of Gd and X-ray beam hardening filters such as Al and Cu. According to the results of experimental evaluation, X-ray property was not changed with variety of kVp in the case of the Gd filter. The surface dose and absorption dose were increased in order of Cu and Al. The contrast of image showed the higher value in order of Cu, Al and Gd. While the use of Gd has increased the numerical value of the CR image, and grayscale has decreased noise value of the DR image.
Moyamoya 질환에서 1차 통과기법을 이용한 자기공명관류영상의 이해
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 12 Number 1 2010.05 pp.27-31
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
The purpose of this study was to investigated the usefulness of MR perfusion image comparing with SPECT image. A total of pediatric 30 patients(average age : 7.8) with Moyamoya disease were performed MR Perfusion with 32 channel body coil at 3T from March 01, 2010 to June 10, 2010. The MRI sequences and parameters were as followed : gradient Echo-planar imaging(EPI), TR/TE : 2000ms/50ms, FA : 90°, FOV : 240×240, Matrix : 128×128, Thickness : 5mm, Gap : 1.5mm. Images were obtained contrast agent administrated at a rate of 1mL/sec after scan start 10s with a total of slice 1000 images(50 phase/1 slice). It was measured with visual color image and digitize data using MRDx software(IDL version 6.2) and also, it was compared of measurement with values of normal and abnormal ratio to analyze hemodynamic change, and a comparison between perfusion MR with technique using Warm Color at SPECT examination. On MR perfusion examination, the color images from abnormal region to the red collar with rCBV(relative cerebral blood volume) and rCBF(relative cerebral blood flow) caused by increase cerebral blood flow with brain vascular occlusion in surrounding collateral circulation advancement, the blood speed relatively was depicted slowly with blue in MTT(Mean Transit Time) and TTP(Time to Peak) images. The region which was visible abnormally from MR perfusion examination visually were detected as comparison with the same SPECT examination region, would be able to confirm the identical results in MMD(Moyamoya disease)judgments. Hymo-dynamic change in MR perfusion examination produced by increase and delay cerebral blood flow. This change with digitize data and being color imaging makes enable to distinguish between normal and abnormal area. Relatively, MR perfusion examination compared with SPECT examination could bring an excellent image with spatial resolution without radiation expose.
검진 기관에서의 선별 유방촬영술 시행에 따른 연령 제한의 필요성에 대한 연구
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 12 Number 1 2010.05 pp.33-41
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
National Cancer Screening Project and Korean Society of Breast Imaging recommend that breast cancer screening should be performed on those aged 40 and above. Nevertheless, this recommendation is usually ignored by a number of medical institutions. The purpose of this study is to emphasize the necessity of an age limitation in screening mammography. Ten institutions were randomly selected and telephone inquiries about patients' age limitation and internal guidelines were set up. The 3,214 women, who underwent screening mammography through ‘GE Senography 2000D’ in each hospital, were classified into five groups according to age(from 20s to 40s, at intervals of 5). And then, collected data was analyzed by a radiologist in accordance with ACR-BIRADS(American College of Radiology Breast Imaging Reporting and Data System), through which breast parenchymal density and the results of analysis were categorized in order to predict the sensitivity of mammography. Information about craniocaudal-view mammograms was automatically produced by use of GE Senography 2000D, and the average glandular dose was retrospectively analyzed through the program ‘Excel 2007.’ Two institutions did not set the age limitation. Other seven institutions internally allowed those who wanted to receive mammography regardless of age. Approximately 99% of those aged 20 to 29 were judged as having the dense breast. In those aged 35 to 39, breast parenchymal density tended to be lower, but the fatty breast to increase. In the case of ‘category-zero’ that does not need additional tests, the rate of ‘heterogeneously dense’ and ‘extremely dense’ reached to 83.1% and 15.1% respectively. Regarding dense breasts, there was no sufficient information for image reading. The glandular dose, applied to 3,214, was 1.47mGy on the average. In those aged 20 to 24 who are sensitive to radiation, the average glandular dose indicated 1.59mGy. Those aged 35 and above showed the lowest value, 1.43mGy. In those aged 35 to 39, the breast tended to change from denseness to fattiness. The average glandular dose was lowest in those aged 35 and above, which suggests that screening mammography should be periodically performed on those aged 35 and above in order that breast cancer may be early detected. On the other hand, in those aged less than 35, it is difficult to analyze mammograms due to the high density of breast parenchyma, and also retakes become frequent. In particular, subjects may be exposed to excessive doses. Accordingly, it should be substituted by breast self-examination or clinical breast examination. In case of need, it is advisable to perform ultrasonography.
Merchant View 촬영 시 환자 편의와 업무 효율성 증대를 위한 새로운 촬영 보조기구 개발 및 유용성 평가
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 12 Number 1 2010.05 pp.43-50
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
The representative study of Patellofemoral Joint Merchant method can show the view for inspection of the sulcus angle, congruence angle and diagnose whether there are the vertical fractures and recognize the degree of dislocation and patella subluxation. However, anatomical correlation about the degree of knee joint curvature changes during position adjustment and distortion of the image reduces reproducibility. In order to resolve these problems, Merchant method needs to use assisting device which reduces the occurrence of repeat projection and effectively to increase unification of examination and the consistency of the image. However, there are disadvantages for patients who take other examinations. For example, they have to change the position for every examination and it might cause the patient's discomfort and increase of examination time. In this study, we newly devised commercial assisting device which improves the reproducibility of the images and reduces inconvenience of patients movement. Further research should be taken to obtain a image without patient’s movement and to reduce the time of the examination than existing method.
고 에너지 광자선의 조사선량 측정 시 전리함의 스템효과 보정계수
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 12 Number 1 2010.05 pp.51-58
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
Ionization chambers often exhibit a stem effect, caused by interactions of radiation with air near the chamber end, or with dielectric in the chamber stem or cable. In this study measured stem effect correction factor for length of ionization chamber from medical linear accelerator recommend to with the use of stem correction method. For a model of the Farmer-type chamber, were used to calculate the beam quality correction factor. These interactions contribute to the apparent measured exposure. Additionally, it needs to consider ionization chamber use of small volume and stem effect of cable by a large field. Linear accelerator generated photons energy and increased dose repeatedly measured by using stem correction method. Stem effect was dependence of the energy and increases with photon energy conditions improved of beam quality. In conclusion, stem effect correction factor was measured within 0.4% calculated according to the exposures stem length and also supposed to determined below 1% of another stem correction method.
방사선치료 장비들의 매일 정도관리를 위한 다용도 모형의 제작
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 12 Number 1 2010.05 pp.59-64
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
We examined the accuracy and efficiency of phantom by applying the designed phantom in order to check daily quality assurance easily by objective criteria and to confirm daily quality assurance of linear accelerator, simulator, and CT-simulator. The results of 10 weeks of linear accelerator output dose using American Association of Physicists in Medicine(AAPM) daily quality assurance guide were measured within ±1% of error. Mechanical check of laser alignment, optical distance indicator(ODI), CT scanner laser and alignment of gantry lasers with the center of imaging plane were measured within ±1mm. Daily average working time for daily quality assurance of radiation therapy equipments was 38 minutes. The designed phantom was easy to install and daily quality assurance was possible with only one installation. The aspects reproducibility and efficiency as well as accuracy of quality assurance were excellent.
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 12 Number 1 2010.05 pp.65-69
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
High energy electron beams were to concentrically dose inside a tumor and more energy is a shape decreased of dose. Therefore, it is useful to radiation therapy of a tumor. Also high energy electron beams ionized into collision with a atom in structure material of tissue and it has big changes to dose distribution by multiple scattering. The study had to establish characteristic of electron beams from interaction of electron beams and materials. Experiment method was to measure dependence of electron beam central axis for depth dose curve, field flatness and symmetry and field size dependence. The results were able to evaluate data for a datum pint of electron beam. Also radiotherapy has to be considered for not only energy pencil of lines but characteristic, electron guide and isodose curves distribution.