Volume 11 Number 2 (10건)
No
1

4,000원

The purpose of this study would evaluate if having clinical effects on diffusion image with quantitative analysis through ADC values of brain’s normal tissue and lesions before and after contrast injections using a 3.0T. From November in 2007 until December in 2008, a total of 32 patient was performed on 3.0T(Signa Excite, GE Medical System, USA) with the normal or lesions in the patient who requests diffusion weighted image with 8channel head coil. The pulse sequence was used with spin echo EPI(TR: 10000msec, TE: 72.2 msec, Matrix: 128*128, FOV: 240 mm, NEX: 1, diffusion direction: 3, b-value: 1000). Measurement results of ADC values on lesions, CSF, white matter, gray matter, lesions after contrast injection were measured less 75% than before contrast injection, infarction: 100%, CSF: 78%(high), white matter: 71.4%(low), gray matter: 50%(high, low). The results of paired t-test on the deference of ADC values which statically is significant in three(lesions, CSF, white matter)regions except for white matter(p<0.05). Quantitative analysis of lesions, CSF, white matter, gray matter have difference on all regions. ADC values were low in lesions and white matter, normal CSF after contrast injection commonly is high than before contrast injection, ADC values which white matter were high and low (50:50) after contrast injection. 3.0T diffusion weighted image clinically supposed that performing DWI examination after contrast injection was not desirable because of having effects on brain tissue.

2

4,000원

The purpose of this study is to know about solution of insecurity sense for solving the tediousness and inducing comfortableness in long time MRI examination. Studies were examined with total of 117 patients that the intention expression of self is possible for a month without dividing man and woman in november 2006. Examination methods were filled in questionnaire after testing using Siemens Impact 1.0T. The musical art were selected through intranet search and record sale inquiry using CD player and speaker. That kind of a music were selected with Korean classical music’s 10 chapter, pop song 10’s chapter, classic’s 10 chapter and Korean popular song’s 10 chapter. With analytical method, patients of under 40 year-old, or older and patients using ear-pad and head-phone were classified into groups. As analysis result with question item of questionnaire, most of the patients were showed a favor(36.72%) in playing a music, specially, examination of about 15.38% which uses the headphone prefer a music as older generation of over 40 year-old. In conclusion, with installing of the professional musical program in MRI test rooms, if listening to the music with selection by oneself before testing by season, age, time through development of appropriate musical program will be able to expect the more effect.

3

ALVIM Phantom을 이용한 화질관리

임득춘, 동경래, 박용순, 김창복, 류영환

대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 11 Number 2 2009.11 pp.63-68

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

Among various physical or subjective assessments of the quality of X-ray images, physical assessments can be quantitative but they are eventually judged by the view of observers thus subjective assessments including the aspect of observers are required. The changes in the ability to detect lesions caused by changes in the thickness of acrylic plates were tested with the ROC interpretation method that has taken into consideration, all the features of physical assessments as well as observers’ ability to observe and mental stages and even surrounding environments using an Alvim phantom and the result indicated that as the thickness of acrylic plates increased, the amount of noises occurred increased compared to signals and thus the ability to detect signals as well as the sensitivity that is an ability to signals accurately and the ability to distinguish noises from signals thus it is considered that more efforts of radiologic technologists will be required to detect small lesions of fat patients with diagnostic X-ray generating apparatus.

4

4,000원

This study gives an account of the collateral standards in IEC 60601-1-3: 2008 specifying the general requirements for basic safety and essential performance of diagnostic X-ray equipment regarding radiation protection as it pertains to the production of X-rays. The collateral standards establish general requirements for safety regarding ionization radiation in diagnostic radiation systems and describe a verifiable evaluation method of suitable requirements regarding control over the lowest possible dose equivalent for patients, radiologic technologists, and others. The particular standards for each equipment can be determined by the general require- ments in the collateral standard and the particular standard is followed in the risk management file. The guidelines for radiation safety of diagnostic radiation systems is written up in ISO 13485, ISO 14971, IEC 60601-1-3(2002)1st edition, medical electric equipment part 1-3, and the general requirements for safety-collateral standards: programmable electrical medical systems. Therefore the diagnostic radiation system protects citizens’ health rights with the establishment and revisions of laws and standards for diagnostic radiation systems as a background for the general requirements of radiation safe guards applies, as an international trend, standards regarding the medical radiation safety management. The diagnostic radiation system will also assure competitive power through a conforming evaluation unifying the differing standards, technical specifications, and recognized processes.

5

u-Health 생활지원시스템 시범 서비스

김선칠, 박기현

대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 11 Number 2 2009.11 pp.79-84

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

Recently, there has been a rapid increase of interest in u-Health systems or instruments. The importance of testbeds has been discussed deeply also. However, beyond laboratory or ward environments, testbeds covering metropolitan area cannot be found easily. Moreover, there has been few papers which discuss the results of testbed operations for various instruments in different age groups. In this paper, the results of testbed which operated in Daegu metropolitan area are discussed and improvement directions to strengthen the competitiveness are proposed using user analysis. In particular, the results of trial services using the u-Life support instruments (medication reminder, falling safety phone, bio-patch and shirts, etc) for super aging societies in the near future are discussed.

6

이동형 방사선 발생장치 차폐물 설치에 관한 연구

김형균, 성동근, 조경미, 김상범, 김재영, 최준호

대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 11 Number 2 2009.11 pp.85-92

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

This study, “The study about performance evaluations of mobile cover for X-ray’s diffusion and distribution in mobile radiation” is based on the rules of mobile defense apparatus for radiation producer in 2006. To use the mobile cover for X-ray for diagnosis has been compulsory in common wards except operation rooms, emergency rooms and intensive care units. we have confirmed the effect in arbitrary shielding material after Qualitiy Control was carried out for accuracy in an experiment of mobile photographing equipment. The performance evaluation was conducted with the fabrics of selenium, 0.2 mmPb, 0.1 mmPb and aluminiums. Considering the result, we choosed 0.1 mmPb and attached cover to mobile photographing equipment. We have finished making the cover after drew up the draft to attach cover to mobile photographing equipment through the modeling and the structural analysis. the process of the study is that we assembled the manufactured structures and carried out the practical experiment to take the photograph after attaching the fabric of 0.1 mmPb to mobile photographing equipment. It is need of additional thesises hereafter that we compare the result between the part to improve for safety besides convenience in photographic experiment about clinical radiation and the effect of covering the diffusion in condition attached the cover.

7

4,000원

This conclusion was from the 3rd grade students of radiologic technology of Daegu Health College who already taken the hospital practice. 231 students answer our question and this study used sampling method. The contents of Questionnaire consisted of normal facts of respondent, Training satisfaction, Training Methods, Practice Environment of Hospital, Problem in Practice Hospital, Before and after views, etc. The statistical program SPSS/Win 10.0 version was used to see the results of the survey data used in. The response contents of brief question were separetely checked and clean.

8

X-선 장치의 기술적 인자의 변화에 따른 선량 비교 평가

한동균, 고신관, 선종률, 윤석환, 정재은

대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 11 Number 2 2009.11 pp.101-107

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

With the recent development of diagnosis using radiation and increasing demand of the medical treatment, we need to minimize radiation exposure dose. So, This is the method which reduce patient dose by measuring surface dose of radiographic change factor and by comparing theoretical and actual dose, when we take an X-ray which is generally used. By changing the factor of kV, mAs, FSD, whose range is 60 to 120 kV, 20 to 100 mAs, 80 to 180 cm, we compared theoretical surface dose with actual surface dose calculated by the simple calculation program, Bit system, and NDD-M method As a result, when kV and mAs were higher, theoretical surface dose and actual surface dose were more increased. but the higher FSD was, the more decreased surface dose was. According to this, the error were measured about 0.1 to 0.2 mGy in low dose part and about 0.7 to 1.5 mGy in high dose part. Therefore, this shows that theoretical surface dose calculation method is more correct in low dose part than in high dose part. In conclusion, we will have to make constant efforts which can reduce patient and radiographer’s exposure dose, studying methods which can predict patient’s radiation exposure dose more exactly.

9

구강 내 촬영용 센서의 정량적 평가

정재호, 정재은, 강희두, 나극환

대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 11 Number 2 2009.11 pp.109-114

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

Carried out an experiment for quantitative evaluation about intraoral sensor among oral dental imaging equipments in PACS environment. For evaluation, testing environment & evaluation criteria are established that refer to the ‘IEC 62220-1-2’ and experimented with set up the standard radiation penetration that correspond with RQA-3(IEC 61267). Results of experiments using the image J, derived the ESF(edge spread function), LSF (line spread function) and calculated the MTF(modulation transfer function) finally. As a result, the MTF that 0.1, 0.2sec are 10% about 10 lp/mm and 0.32 sec is the 10% about 9 lp/mm in level represents the value of the MTF. Change of scan condition in dental environmental, according to the MTF value taken note that no changes can be seen enough. However, the dimensions of each other size 1(1200×1600), size 2(1440×1920) intraoral sensors for 3 lp/mm, respectively 40%, 90% of the note might have been the difference between the value of MTF, in accordance with standard sensors might note differences could be observed.

10

치과 방사선 발생기의 성능평가에 관한 연구

정재은, 정재호, 강희두, 이종웅, 나극환

대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 11 Number 2 2009.11 pp.115-119

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

 