자궁난관 조영술 검사 시 Speculum 재질에 따른 흡수선량의 변화에 관한 연구
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 13 Number 1 2011.03 pp.1-6
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
The purpose of our study was to determine the entrance surface dose and absorbed dose in ovary when using the metal speculum and plastic speculum in hysterosalpingography respectively. The examinations was performed in anthropomorphic phantom into which calibrated photoluminescence glass dosimeter were placed on symphysis pubis level surface and ovary area. We checked average fluoroscopy time and spot expose times during the hysterosalpingography. It was average fluoroscopy time 58 sec, spot expose 5 times. We divided the subjects into two different groups to used metal and plastic speculum. We measured 10 times of absorbed dose in the same condition of the anthropomorphic phantom. We compared two groups adsorbed dose on ovary with speculum material-related. The entrance surface dose on of plastic Speculum using group was average 17.23 mGy, absorbed dose on ovary was average 3.51 mGy. The entrance surface dose on ovary of metal Speculum using group was average 19.95 mGy, absorbed dose on ovary was average 4.14 mGy. Plastic speculum using group shows a decrease absorbed dose(17.9%) as compared with metal speculum using group. The method of plastic speculum using in hysterosalpingography. might provide us with lower radiation dose, especially in patients with childbearing stage.
A Study on the Isodose Distribution in a Vascular Characterization Room
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 13 Number 1 2011.03 pp.7-11
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
As applications of radiation grow wider from use in the early detection of lesions and preventive diagnosis purposes to the treatment of diseases, the possibilities for patients and working professionals to be exposed to radiation are becoming greater than ever. This can not only directly bring about an increase in patient’s individual radiation exposure, but also brings about an increase in the annual radiation dose of working professionals. Therefore, research and countermeasures to reduce radiation dosage are required. In this study, space dosimetry has been divided into two separate measuments with an understanding of the increasing number of angiography procedures: front perspective and side perspective. According to the results of the isodose curve, a way to minimize radiation exposure in working professionals has been suggested. This was made possible by workers through awareness of suitable working positions.
The Research about Role Area of RT in Digital Environment - Centers on PACS Workplace -
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 13 Number 1 2011.03 pp.13-20
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
Now a days in our society, occupation boundaries have become blurred, and come into the limelight in the prior occupation or miss about new workplace. Medical area is no exception also, So we face urgent problem about protecting and spreading RT work-sphere simultaneously. This research allow to identify on RT role area of digital environment that is obscure profession-realm specially, and open up a new field hereafter. We examined present RT role area of digital environment in the more than thirty medical facility(general or university hospital) through questionnaire/visit survey from PACS administrator. Survey sentence comprises total 29 sentence over all main quadrisection-(eX. hospital formation & treatment state and PACS team composition & organization and PACS team workplace and PACS team daily workload), We performed comparative analysis in general contents perspectively. further more, divided main 5 section based on upper analysis and then manufactured output in consideration of each medical facility's operation state. There are comparative problem of hospital policy, So we maintained information security of each facility exhaustively. First, we separated a survey output into main 5 section as follows-(eX. PACS server & maintenance manage, Client/interlock manage, PACS data conversion, 3D reconstruction, PACS data im/export)-that received by 35 medical facility. And then manufactured output with comparative analysis about RT role area each section, general IT managing team about medical environment was out of existence that fill up with RT manpower in the surveyed medical facility consequently. What is worse, hospitals that entirely fill up with another worker were 3 place amazingly. Our specific statistic results show, the respondents was 63% that agree with reorganization of formation base on independence team, and supplement of the personnel average -continuous with upper agreement simply-was about 2.64. Further more, if reorganization break out with only RT manpower, quota TO will increase by geometric progression. Protecting and spreading role workplace is much accounted of the our inevitable project surely and more than 95% PACS administrator's have confidence in this proposition unconditionally. Henceforth, look forward to meeting the RT vision of many-sided multiplayer, based on acquire a specialized IT knowledge actively and open up a new work-field with frontier spirit.
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 13 Number 1 2011.03 pp.21-26
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
A radiation imaging system used in a surgery room is mainly using C-arm which is purposed to fluoroscope. C-arm is often use to watch an operation's accuracy and progress, but not only being bombed to this first beam but also affected to this scattered beam, so now we are look for the way to reduce bombed amount of doctor, nurses and radiological technologists. We measured the exposure dose in 0˚ spot according to the distance to find out frequency distribution of scattered ray in an operation room and found the spot which has the same exposure dose from 30˚ distance of all directions and wrote isodose curve. We analyzed the data and found out the sudden reduction of scattered ray according to the long direction also found out that scattered ray was not related to the directions. Operators must recognize the reduction of exposure dose. Because reducing scattered ray from all directions in an operation room is really difficult. So every operators must use shelters to reduce the exposure dose and notice the safety.
인버터식 X선발생장치의 출력특성개선이 환자피폭선량 경감에 미치는 효과
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 13 Number 1 2011.03 pp.27-32
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
The conventional types of X-ray generators were bulky in physical size and heavy in weight, and the control accuracies of the output voltages were not always satisfactory. The high frequency switching inverter and converter technology on power conversion and control systems have been greatly closed up introducing power semiconductor devices. To decreasing the volume and the weight of high voltage transformer, and to stabilize ripple. In this paper, the newly developed x-ray generator in a low cost using duty modulation PWM inverter. This system verify improved performance by stabilize ripple of X-ray tube voltage and compared the reproducibility, linearity and dose in single phase, three phase and PSU.
외부영상정보 입력 시 DICOM정보 충실성에 대한 평가 - DICOM Validation Tool 이용 -
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 13 Number 1 2011.03 pp.33-38
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
Now a days, there's many change over for PACS among the most of hospital and it standard for DICOM 3.0. These kind of using of DICOM 3.0 improves increasing of medical imaging exchange and service for patient. However, there's some problems of compatibility caused during carry out CD and DVD from hospital. For this reason, this thesis analyzed patients image targeting those storages requested to hospitals in Seoul by using Validation Toolkit which is recommended from KFDA. The analyze type is like this. Make 100 data, total 500, each of MRI·CT·Plain x-ray·Ultrasound·PET-CT images and analyzed type of error occurred and loyalty of information. If express percentage of error occurred statistically, we can get a result as follows MRI 5%, Plain x-ray 11%, CT 18%, US 25%, PET-CT 30%. The reson why percentage of error occurred in PET-CT is because of imperfective support and we could notice that we weren't devoted to information. Even though, PET-CT showed highest percentage of error occurred, currently DICOM data improved a lot compare to past. Moreover, it should be devoted to rule of IHE TOOL or DICOM. In conclusion, we can help radiographer to analyze information of image by providing clues for solving primary problem and further more, each of PACS company or equipment company can enhance fidelity for following standard of image information through realizing the actual problem during transfer of image information.
단층촬영영상을 이용한 T.O.D Calibration의 정확성과 유용성에 관한 비교연구
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 13 Number 1 2011.03 pp.39-48
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
Uses a Tomographic scan image and Table Object Distance(TOD) price after measuring, uses accuracy and usability of blood vessel diameter(Vessel Diameter) measurement under comparison evaluating boil TOD Calibration. The patient who enforces Prosecuting Attorney abdomen Tomographic scan in the object the superior mesentery artery uses PACS View from abdomen fault image and from blood vessel diameter and the table measures the height until of the blood vessel. Uses Angio Catheter from Angiography(5 Fr.) and enforces is measured from PACS View the height until of the table which and the blood vessel at TOD Calibration price and the size of the superior mesentery artery inputs measures an superior mesentery artery building skill. Catheter Calibration input Agnio Catheter where uses in Angiography the size of the superior mesentery artery at Catheter Calibration price and they measure. Produced an accuracy from monitoring data and comparison evaluated. The statistical program used SPSS. TOD Calibration accuracy was 96.53%, standard deviation is 0.03829. Catheter Calibration accuracy of 92.91%, standard deviation is 0.05085. Represents a statistically significant difference(p = 0). According to age and gender was not statistically significant(p > 0.05). TOD Calibration correlation coefficient R-squared of 88.8%, Catheter Calibration of the R-squared is 75.5%. High accuracy of both methods. Through this study, CT images using the measured distance between the table and the Object, TOD Calibration accuracy higher than two Catheter Calibration was measured. TOD and Catheter Calibration represents a statistically significant difference(p = 0).
디지털 방사선에서 조사선량과 관전압조절에 의한 원본영상과 처리영상 분석
대한디지털의료영상학회 대한디지털의료영상학회논문지 Volume 13 Number 1 2011.03 pp.49-53
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
Dynamic range on the digital detector can be a representation to the ratio of maximum and minimum of pixel value. Wide dynamic range and post processing ability of the digital detector made difficult to recognize visually to high or low dose images. We were evaluated a change of mean pixel value on the original and processed image, when we controlled the kVp, mA, exposure time on the digital detector. On the kVp of a constant condition, we were acquired an original and processed image by changes of mA, exposure time. According to the thickness of the subject under the same conditions, to determine a relation of pixel value and X-ray intensity, we used an aluminum step wedge. When mA and exposure times were changed under the kVp of a constant condition, the X-ray intensity was decreased by the reduction of the mean pixel value. In addition when kVp was increased in a constant condition of mAs, the mean pixel value was increased according to the increment of the X-ray intensity. Therefore, low kVp, high mA and short exposure time were a way to reduce a patient dose.