Purpose : The relaxation times of tissue in MRI depend on strength of magnetic field, morphology of nuclear, viscosity, size of molecules and temperature. This study intended to analyze quantitatively that materials’ temperatures have effects on T1 and T2 relaxation times without changing of other conditions. Materials and Methods : The equipment was used MAGNETOM SKYRA of 3.0T(SIEMENS, Erlagen, Germany), 32 channel spine coil and Gd-DTPA water concentration phantom. To find out T1 relaxation time, Inversion Recovery Spin Echo sequences were used at 50, 400, 1100, 2500 ms of TI. To find out T2 relaxation time, Multi Echo Spin Echo sequences were used at 30, 60, 90, 120, 150, 180, 210, 240, 270 ms of TE. This experiment was scanned with 5 steps from 25 to 45°C. next, using MRmap(Messroghli, BMC Medical Imaging, 2012) T1 and T2 relaxation times were mapped. on the Piview STAR v5.0(Infinitt, Seoul, Korea) 5 steps were measured as the same ROI, and then mean values were calculated. Correlation between the temperatures and relaxation times were analyzed by SPSS(version 17.0, Chicago, IL, USA). Results : According to increase of temperatures, T1 relaxation times were 214.39±0.25, 236.02±0.87, 267.47±0.48, 299.44±0.64, 330.19±1.72 ㎳. T2 relaxation times were 180.17±0.27, 197.17±0.44, 217.92±0.39, 239.89±0.53, 257.40±1.77 ㎳. With the correlation analysis, the correlation coefficients of T1 and T2 relaxation times were statistically significant at 0.998 and 0.999 (p<0.05). Conclusion : T1 and T2 relaxation times are increased as temperature of tissue goes up. In conclusion, we suggest to recognize errors of relaxation time caused local temperature’s differences, and consider external factors as well in the quantitative analysis of relaxation time or clinical tests.

목차

Abstract
1. 서론
2. 대상 및 방법
3. 결과
4. 고찰 및 결론
참고문헌

키워드

Temperature Molecular tumbling Relaxation time Mapping Correlation analysis

저자

  • 김호현 [ Ho-Hyun Kim | 건국대학교병원 영상의학팀 ]
  • 권순용 [ Soon-Yong Kwon | 건국대학교병원 영상의학팀 ]
  • 임우택 [ Woo-Teak Lim | 건국대학교병원 영상의학팀 ]
  • 강충환 [ Chung-Hwan Kang | 건국대학교병원 영상의학팀 ] Corresponding Author
  • 김경수 [ Kyung-Soo Kim | 건국대학교병원 영상의학팀 ]
  • 김순배 [ Soon-Bae Kim | 건국대학교병원 영상의학팀 ]
  • 백문영 [ Moon-Young Baek | 지멘스 코리아 ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한디지털의료영상학회 [대한디지털의료영상학]
  • 설립연도
    1995
  • 분야
    의약학>방사선과학
  • 소개
    대한디지털의료영상학회는 디지털 영상 기술에 관한 연구와 실험 결과를 임상에 적용하여 영상의학 및 진단 방사선 기술 분야의 발전에 기여함을 목적으로 한다.

간행물

  • 간행물명
    대한디지털의료영상학회논문지 [Korean Journal of Digital Imaging in Medicine]
  • 간기
    연3회
  • pISSN
    1976-7641
  • 수록기간
    1995~2025
  • 십진분류
    KDC 510 DDC 610

이 권호 내 다른 논문 / 대한디지털의료영상학회논문지 Volume 15 Number 2

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장