Earticle

현재 위치 Home

Issues

대한안전경영과학회 학술대회논문집

간행물 정보
  • 자료유형
    학술대회
  • 발행기관
    대한안전경영과학회 [Korea Safety Management & Science]
  • 간기
    부정기
  • 수록기간
    1999 ~ 2022
  • 주제분류
    공학 > 안전공학
  • 십진분류
    KDC 530 DDC 620
2015년 대한안전경영과학회 추계학술대회 (68건)
No
31

4,000원

33

4,800원

Currently, the construction industry in Korea implements the risk assessment that is implemented by managers and working team leaders. However, it is difficult to share the result of risk assessment meeting to substructural workers in korea system and the workers don't understand meaning and effect about risk assessment. The risk assessment is that the workers in the construction site have to know risk factors and reducing ways to the risks. But, the education and sharing methods for risk assessment system is insufficient in korea. For this risk assessment problems identified were surveyed. In order to improve the problems of the risk assessment, proposes the following three methods. First, Implement to educate the risk assessment during the basic safety and health training of construction industry. Second, the training way about workers' participation in risk assessment is necessary. For example, after watching videos, etc, the workers create risk assessment in person and make a presentation about it. Third, the risk assessment utilize during TBM(Tool Box Meeting). Before working every day, we need to educate risk factors and the reducing ways to the risk during TBM.

35

6,000원

36

4,500원

39

4,200원

44

4,000원

45

4,000원

46

보건학과 학생들의 방사선 방어에 관한 지식 및 태도연구

조윤서, 박용민, 정종언, 곽나영, 최성욱, 선종률

대한안전경영과학회 대한안전경영과학회 학술대회논문집 2015년 대한안전경영과학회 추계학술대회 2015.11 pp.457-475

※ 기관로그인 시 무료 이용이 가능합니다.

5,400원

47

Brain CT 검사 시 수정체 차폐체에 관한 유용성 연구

이현지, 고설빈, 김성연, 이도훈, 홍성우, 서선열

대한안전경영과학회 대한안전경영과학회 학술대회논문집 2015년 대한안전경영과학회 추계학술대회 2015.11 pp.476-485

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

Because the lens is a tissue with the highest sensitivity, the lens shielding is very important in CT imaging. However, in clinical terms, there is a lack in the efforts in decreasing dosage on the lens, and the shielding of dosage and the effects on the imaging are researched using bismuth to evaluate the usefulness. As results of the dosage evaluation results, when there is no gantry angle when the thickness of the lens shielding material is 0mm, the dosage was 28.476mGy, and when there is gantry angle, the dosage was 20.852mGy that it was confirmed that the dosage was 27% lesser with gantry angle. It was confirmed that the dosage value decreased with the increase of thickness of lens shielding material when there is gantry angle, and when the lens shielding material was 1mm, the dosage decreased by approximately 39% compared to when it was 0mm. When there is gantry angle, the dosage values were respectively 12.788mGy and 12.776mGy for the crystalline lens shielding material thicknesses of 0.75mm and 1.0mm. In image analysis, the quantitative evaluation and the qualitative evaluation were almost constant regardless of the thickness of the lens shielding material. The optimal lens shielding material thickness to minimize the does of lens and increase the value of diagnosis in Brain CT examination is 0.75mm. Therefore, if this is utilized for easier use in clinical practices, it is considered to be able to contribute to not only the protection of the lens but the accurate diagnosis of diseases.

48

방사선사 직무분석을 통한 환자안전 개선 연구

오관용, 박용찬, 서보연, 오예지, 이하성, 최성욱, 선종률

대한안전경영과학회 대한안전경영과학회 학술대회논문집 2015년 대한안전경영과학회 추계학술대회 2015.11 pp.486-495

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

49

혈관조영실에서 중재적 시술 시 필요한 시술 보조기구 제작과 유용성 평가

서선열, 강성현, 김용훈, 연다은, 배상규, 고현희, 전용석

대한안전경영과학회 대한안전경영과학회 학술대회논문집 2015년 대한안전경영과학회 추계학술대회 2015.11 pp.496-503

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

When using the original Angio Intervention, one had to put Guide wire, Catheter on patient's leg so that there were curves according to patients and the possibility of patients moving made it inconvenient to proceed. Thus, by making supplementary tool shaped of table, it minimized the inconvenience of patients and operator, increasing the convenience of the process and thereby evaluating the utility and its usefulness. The main material of supplementary tool was used with cost efficient Fomax material, and by considering the patient's lower limb, and the length of tools when doing Angio Intervention, it was made as 1300mm, 600mm at the front, 500mm at the back. Also, considering the weight of the tool, it was manufactured with thickness of 5mm and 10mm with the same design, and evaluated by using survey of 14 medical personnel using the tool in A University Hospital, Daejeon. When manufacturing and using supplementary tool, it became heavier as the thickness increased. Whereas, the thinner, the lighter the tools were, however, had unstability which cause lack of safety. Despite the fact, they responded that they had more convenience of using 5mm and 10mm tool compared to when they did not have at all, and through this, we could evaluate that the use of supplementary tool is useful to the procedure. Accordingly, when doing Angio Intervention, we could find out that it is useful to use the supplementary tools, and by reducing the weight and increasing the safety, if we can make use of this kind of supplementary tools, it would be more useful to the procedure.

51

4,500원

엔진 시 운전 후 엔진 내부 주요 부품 상태를 검사하기 위해 분해하는 작업을 엔진 개방 작업 공정이라 하는데 엔진 개방 작업 공정 중 콘 로드 분해 시간이 평균 대당 187.8분으로 표준 시간 90분을 과도하게 초과하여 시급히 개선이 요구 되어 현상파 악, 원인분석, 대책수립 및 실시를 하여 개선 후 86.7 분으로 감소하여 생산성 향상으 로 인한 원가절감을 연간 4200만원 달성하였다.

52

4,500원

시멘트제조공정에서 중요공정인 슬래그 미분말 공정 중에서 분슬래그 이송공정 정 지시간을 조사해 보니 84.6% 차지하여 생산성의 매우 낮은 실정이라 시급히 개선이 요구 되어 QC 문제해결 과정을 통해 개선전 3.45 (h/일)에서 개선후 1.09 (h/일)으로 낮 추어 연간 5400만원을 절감하였다.

53

4,000원

지난 몇 십년동안 전 세계적으로 제조기술 분야의 급속한 성장으로 대부분의 제조 업에서 눈부실만한 품질향상과 생산성 극대화를 이루어 왔다. 하지만 현재 제조기술 분야는 새로운 문제에 직면하고 있다. 실제 현장에서 관리하고자하는 품질특성은 정규 분포를 따르지 않는 경우가 많은데, 대부분의 통계적 공정관리기술체계가 정규분포를 기반으로 하고 있다는 것이다. 또한 기존의 불량률 관리도로는 PPM/PPB 수준의 극소 불량률을 관리하는데 한계가 있다. 이러한 이유로 비정규 공정에서 극소불량관리, 미 세변동관리에 대한 연구가 시급한 실정이다. 본 논문에서는 비정규 공정에서 극소 불량률을 관리하기 위해서   통계량에 Burr 분포를 적용하는 방법을 제안하고자 한다.

55

4,000원

초가속수명시험(HALT:Highly Accelerated Life Test)은 온도변화와 진동을 통해 부품초기 고 장을 빠르게 찾아 개선함으로써 제품의 신뢰성을 향상시킨다. 이에 따라 기업들은 초가속수명시 험에 집중하게 되었고 장비의 수요와 가동률이 증가하고 있다. 그러나 초가속수명시험 장비는 대부분 해외 장비에 의존하고 있어 고장이 발생한 경우 유지보수에 대한 비용이 높고 보전까지 의 시간 또한 길다. 뿐만 아니라 장비에 대한 적절한 보전절차가 없어 비용과 시간의 손실이 발 생되는 실정이다. 본 논문에서는 국산화 개발중인 초가속수명시험 장비에 고장유형과 원인에 따른 계획보전 활 동을 진행 할 수 있도록, FMEA(Failure Modes and Effects Analysis)를 사용하여 계획보전절 차를 제시하였다.

57

4,000원

58

4,000원

59

4,000원

본 연구에서는 플랜트 공사 저장탱크 붕괴 사고사례 원인에 대한 연구를 수행하였다. 저장탱크란 기 름, 물, 가스 기타 약품등과 같은 유체를 효율적으로 저장하기 위하여 인공적으로 만들어진 지상의 저장 시설을 총칭해서 말하는데, 일부 업체들은 군집된 저장소(Tank Farm)를 보유하고도 있다. 저장탱크 시 공 방법을 보면 저장물의 성분 및 종류에 따라서 탱크 종류가 결정되는데 대부분 작업이 중량물을 건설 중장비를 동원하여 높은 곳에서 이루어지는 작업 형태를 갖추고 있어 일반 공종 작업에 비해 훨씬 많은 위험 요인을 내포하고 있는 실정이다. 최근에 들어 저장탱크 붕괴 등의 중대한 사고가 빈번하게 발생하 는 바, 구조물 특성상 자칫 대형 인명사고로 발전하는 경우가 많다. 본 발표에서는 최근 들어 발생한 저 장탱크 붕괴 사고사례을 통하여 이에 대한 원인을 파악 하고자 한다.

 
1 2 3
페이지 저장