Earticle

현재 위치 Home 검색결과

결과 내 검색

발행연도

-

학문분야

자료유형

간행물

검색결과

검색조건
검색결과 : 718
No
3

4,000원

The air conditioner is an instrument to make a low degree fresh wind by compress a refrigerant and through the heat exchanger. As change a refrigerant of low degree and low pressure to high degree and high pressure, it is needed to the compressor. The compressor compress a refrigerant by transfer the rotational energy to reciprocating energy. The goal of this research is for easy use to failure diagnosis of an automotive compressor according to vibration characteristics of each failure types of automotive compressor. To do this, we have prepared the normal products and made some detective products which several kinds of detective types to measure and analysis of vibration characteristics. From the results, we have made a close investigation into the vibration characteristics of each kinds of detective type.

4

4,000원

In this study, the initial operation characteristics of a multi-type cooling system with three indoor units using an inverter compressor were investigated experimentally using a calorimeter. The operating characteristics of the cooling system were confirmed under the full load condition of simultaneous operation of three rooms and the partial load condition of individual operation of two or one room under the standard cooling conditions. The capacities of A, B and C are 50, 20, and 30% of the total capacity, respectively. The 3 room combination has 100% capacity, the 2 room combination has 50, 70 and 80% capacity, and the 1 room has 20, 30, and 50% capacity. The compressor condensing and evaporating pressures, the electronic expansion valve openings of indoor units A, B, and C, and the compressor operating frequencies were measured for 10 minutes after the cooling system was started. During the initial operation, the changes in the operating time and opening of the electronic expansion valve varied depending on the indoor unit combination and the operating load, and the relationship between the compressor pressure and the operating frequency was found.

5

4,000원

In this study, the calorimeter was used to experimentally investigate the cooling characteristics of the variable A/C system according to changes in loading time and outdoor dry bulb temperature. The cooling capacity, COP and compressor discharge temperature were measured while changing the loading time of the compressor. To develop the correlation for compressor discharge temperature, loading time, indoor and outdoor dry bulb temperatures, evaporation and condensation temperatures were considered as operating variables. As the loading time increased, the cooling capacity and COP increased. The cooling capacity increased linearly with the loading time. The COP increased more at low loading times than at high loading times. The change in condensing temperature according to the loading time had a small temperature fluctuation range, and the evaporation temperature decreased linearly. The compressor discharge temperature increased linearly with the loading time and outdoor temperature, and the maximum deviation between the experimental value and the correlation was within about 2℃.

6

4,000원

In this study, the calorimeter was used to experimentally investigate the heating characteristics of the variable A/C system according to changes in loading time and outdoor dry bulb temperature. The heating capacity, COP and compressor discharge temperature were measured while changing the loading time of the compressor. To develop the correlation for compressor discharge temperature, loading time, indoor dry bulb temperature and outdoor dry bulb temperatures were considered as operating variables. As the outdoor temperature and loading time increased, the heating capacity and COP increased. However, the change in COP showed different trends depending on the outdoor temperature. The evaporation temperature according to the loading time is a good estimate of the outdoor temperature. However, as the temperature difference between indoor and outdoor rooms decreases and the loading time increases, the condensation pressure increases significantly, so the condensation temperature increases. The maximum deviation between the correlation and the experimental value for compressor discharge temperature was within approximately 2℃.

7

4,000원

In the present study, a calorimeter was used to experimentally investigate the cooling capacity and COP changes according to the pipe length of a variable capacity A/C system with long pipes. Cooling capacity, COP, and compressor discharge temperature were obtained by changing pipe length and loading duty. And the operation status and cycle change process of the A/C system were investigated using some experimental data and P-h diagrams. In long pipes, the pressure drop increases and the operating load on the compressor increases. Additionally, at the same loading duty, cooling capacity and COP decrease and the compressor discharge temperature increases. As loading duty increases, cooling capacity and compressor power consumption increase. Since the temperature deviation between the experimental value and the correlation equation for the discharge temperature of the long-pipe compressor shows a maximum of 10.5℃(50m, L/D : 20/0), the existing correlation equation needs to be modified.

8

4,000원

In the present study, a calorimeter was used to experimentally investigate the cooling capacity and COP changes according to the pipe length of a variable capacity A/C system with long pipes. Cooling capacity, COP, and compressor discharge temperature were obtained by changing pipe length and loading duty. And the operation status and cycle change process of the A/C system were investigated using some experimental data and P-h diagrams. In long pipes, the pressure drop increases and the operating load on the compressor increases. Additionally, at the same loading duty, cooling capacity and COP decrease and the compressor discharge temperature increases. As loading duty increases, cooling capacity and compressor power consumption increase. Since the temperature deviation between the experimental value and the correlation equation for the discharge temperature of the long-pipe compressor shows a maximum of 10.5℃(50m, L/D : 20/0), the existing correlation equation needs to be modified.

9

4,000원

In this study, the cooling performance of a variable capacity A/C system was experimentally studied. A psychrometric calorimeter was used to obtain performance data of the A/C system using the pulse width modulation method and compare it with the compressor discharge temperature correlation equation. Cooling capacity, COP, and compressor discharge temperature were obtained by changing indoor and outdoor temperatures, refrigerant amount, and loading duty. The following results were obtained by selecting 5 types of refrigerant amount, 3 types of outdoor temperature (fixed indoor temperature), and 2 types of loading duty. As the outdoor temperature increased, cooling capacity and COP according to outdoor conditions decreased. And the higher the loading duty, the greater the cooling capacity, but the COP was minimal. The change in cooling capacity and COP due to the increase in refrigerant amount was not significant. Additionally, the change in compressor discharge temperature is more influenced by the outside temperature than by the loading duty.

10

4,000원

In this study, the heating performance of a variable capacity A/C system was experimentally studied. A psychrometric calorimeter was used to obtain performance data of the A/C system using PWM(pluse width modulation) method and compare it with the compressor discharge temperature correlation equation. Heating capacity, COP, and compressor discharge temperature were obtained by changing indoor and outdoor temperatures, refrigerant amount, and loading duty. The following results were obtained by selecting 5 types of refrigerant amount, 3 types of outdoor temperature (fixed indoor temperature), and 2 types of loading duty. As the outdoor temperature increases, heating capacity and COP increase. Heating capacity was affected by both outdoor temperature and loading duty. However, COP was more influenced by outdoor temperature. The effect of increasing the amount of refrigerant on the performance of the A/C system was not significant. Additionally, the temperature deviation between the existing compressor discharge temperature correlation equation and the heating experiment data was about 5.1℃ at the maximum loading duty.

11

4,000원

The change in the performance of the range hood according to the pressure change was investigated through a comparative experiment, and the conclusion is as follows. KS C 9304: In 2020, static pressure was applied at 100 Pa according to the fan standard, and the test was conducted by varying the outlet diameter and power consumption. In the case of Motor power 55W, the air volume value was 184.6 when the outlet diameter was 125mm. As a result of the test, if the power consumption is 52.0W, the diameter of the outlet is 125mm, and the power consumption is 60.8W, and the diameter of the outlet is 100mm, it meets 160 or more and less than 200 (constant pressure 100Pa).

12

4,000원

In the present study, the experimental study was conducted using a multi-calorie meter, to investigate the cooling performance and cycle operation changes of the multi-heat pump (3 indoor units) for the low outside temperature in summer. The test temperature condition was the low cooling temperature, and the normal performance and dynamic behavior of 3 rooms, 2 rooms, and 1 room were measured to understand the operating characteristics of seven 7 indoor unit combinations. As a result of the experiment, the cooling capacity and COP of the multi-heat pump at low cooling temperature were about 10% and 6% higher than those of the cooling standard temperature. In addition, the dynamic behavior of the indoor units of 3 and 2 rooms was observed differently due to the load difference according to the indoor unit combinations and the non-uniformity of the refrigerant amount. And, when starting the heat pump, the compressor had a maximum peak value and stabilized by repeating the decrease and increase for each indoor unit combination.

13

응축기를 중심으로 한 냉장고 발화 위험성에 관한 연구 KCI 등재후보

함승훈, 김재혁, 박종인, 이대우, 박태용

한국화재감식학회 한국화재감식학회 학회지 제13권 제3호 2022.09 pp.69-85

※ 기관로그인 시 무료 이용이 가능합니다.

5,100원

This study reconstructed the actual fire scene and studied the risk of low-temperature ignition in the insulation material due to the heat generated when compressed refrigerant gas moves from the compressor to the condenser of the refrigerator. In addition, when the refrigerator door is open, the thermal change pattern of each part of the condenser over time was compared and analyzed. As a result of the experiment, considerable heat was generated in the process of moving from the compressor to the condenser, and when the refrigerator door was forcibly opened, the heat continued to accumulate, and it was found that the low-temperature accumulation in the insulation material could cause ignition. Through the results of this study, the ignition mechanism and fire detection options were derived to reconfigure and restore the fire scene in case of a fire due to heat storage while the refrigerator is opened.

14

4,000원

In order to experimentally investigate the operation characteristics of the multi-heat pump with 3 indoor units, the dynamic characteristics of the cooling cycle is studied using the psychrometric multi-calorimeter. The compressor of the heat pump is the scroll inverter type, and since 3 indoor units operate cooling at the same time, it is operated at 100% full load. In particular, 3 types of indoor unit temperatures (20, 24, 26°C) are selected to understand the operation process of the multi-heat pump by the setting temperature. From this experiment, the compressor controls the EEV opening for each indoor unit while varying the frequency according to the initial start, transient, and steady operation. In addition, as the setting temperature increases in the steady range, the frequency of the compressor and the average opening degree of the EEV decrease.

15

4,000원

In the present study, it is conducted to understand the heating performance and compressor operation characteristics according to 7 indoor unit combinations and 3 setting temperatures of the inverter multi-heat pump under heating standard temperature conditions. Heating capacity, COP and compressor frequency are investigated using the multi-calorimeter. The indoor unit combinations are simultaneous operation(A+B+C), partial operation(A+C, A+B, B+C) and independent operation(A, B, C), and the setting temperature is 20, 21, and 30°C. Since the increase in the setting temperature increases the compress frequency, the heating capacity increases, but COP decreases due to the increase in power consumption. The frequency increases as the indoor unit combination capacity increases, and decreases as the setting temperature decreases in the steady state.

17

4,000원

18

4,000원

19

4,000원

20

Dynamic evaluation of a helium compressor testbed for 5TPD hydrogen liquefaction KCI 등재 SCOPUS

Byeongchang Byeon, Mo Se Kim, Dongmin Kim, Junghyun Yoo, Sang Yoon Lee, Gi Dock Kim, Jung Hun Kim, Jaehwan Lee, Jungmin Lee, Kiyoung Baik, Keun Tae Lee

한국초전도저온학회 (구 한국초전도저온공학회) 한국초전도·저온논문지 (구 한국초전도저온공학회논문지) Vol.27 No.4 2025.12 pp.35-42

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

This study presents a dynamic simulation-based evaluation of a large-scale helium compressor test system developed for a 5-ton-per-day (TPD) hydrogen liquefaction plant. A one-dimensional transient simulation tool, EcosimPro, equipped with the CryoLib library was used to model the thermofluid behavior of the helium circulation loop and investigate start-up and pressure-control strategies relevant to helium refrigeration systems in cryogenic processes. The analysis focused on the coordinated operation of three pressure control valves—PCV501, PCV504, and PCV505—that regulate the suction and discharge pressures of the compressor. Through a series of dynamic simulations, appropriate control logic for stable pressurization and pressure regulation was derived. Sensitivity analysis further revealed that an initial loop pressure between 7 and 10 barA yields the most stable start-up condition. These findings demonstrate the usefulness of dynamic modeling using EcosimPro–CryoLib for optimizing control strategies in helium-based thermofluidic systems and provide valuable guidance and reference data for the future operation of hydrogen liquefaction infrastructure.

 
1 2 3 4 5
페이지 저장