This study reconstructed the actual fire scene and studied the risk of low-temperature ignition in the insulation material due to the heat generated when compressed refrigerant gas moves from the compressor to the condenser of the refrigerator. In addition, when the refrigerator door is open, the thermal change pattern of each part of the condenser over time was compared and analyzed. As a result of the experiment, considerable heat was generated in the process of moving from the compressor to the condenser, and when the refrigerator door was forcibly opened, the heat continued to accumulate, and it was found that the low-temperature accumulation in the insulation material could cause ignition. Through the results of this study, the ignition mechanism and fire detection options were derived to reconfigure and restore the fire scene in case of a fire due to heat storage while the refrigerator is opened.
목차
Abstract 1. 서론 1.1 연구배경 1.2 연구의 필요성 1.3 연구과제 선정 이유 2. 이론적 고찰 2.1 냉장고의 개요 2.2 냉장고의 냉각 사이클링(Cycling) 2.3 단열재의 구성 2.4 고분자 화합물의 훈소 개요 2.5 선행연구 검토 3. 응축기를 중심으로 한 냉장고 발화 위험성 화재재현실험 3.1 연구가설 3.2 실험장치(시료) 3.3 실험개요 4. 결론 4.1 냉장고 문 개방에 따른 응축기의 과열 4.2 응축기의 과열에 의한 단열재의 발화 가능성 확인 4.3 화재감식기법 개발 4.4 냉장고 응축기 과열에 의한 화재 예방대책 참고문헌
화재의 과학적 감식, 원인규명 및 예방을 위한 학문과 기술의 발전을 도모하고, 산, 학, 연, 정의 상호 교류를 통한 화재예방과 조사 및 감식의 전문화와 함께 소방관련 정책방향 발전에 공한하며, 회원 및 화재 관련 분야의 국.내외 인사들과의 정보 교류를 위하여 설립되었다.
간행물
간행물명
한국화재감식학회 학회지 [Magazine of Fire Investigation Socity of Korea]