년 - 년
활성탄집진시설의 시간변화에 따른 총탄화수소의 집진효율성 및 경제성에 관한 연구 KCI 등재
대한안전경영과학회 대한안전경영과학회지 제16권 제2호 2014.06 pp.231-236
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
In this study, the changes in collection efficiencies due to the time changes of activated carbons were ascertained, and in order to identify the magnitude of adsorption, the before-use and after-use iodine adsorption values were analyzed. In addition, as a result of examining the characteristics of continuous process and non-continuous process and as a result of investigating whether the emission standards would be maintained, the continuous process and printing facilities were seen as not being able to maintain the emission standards. Also were found, in the case of non-continuous process,–taking into consideration the special nature of the job –for 4Ø palletized charcoal, a collection efficiency near 50% was shown even after 96 hours. Also, when the inlet concentration was about 300ppm, it is thought that the emission standards would be maintained if the activated carbons are replaced within at least 96 hours in the case of 4Ø palletized charcoal and the use was deemed pointless in the case of carbon. The results of this study are expected to provide assistance in selecting replacement periods for activated carbons and in selecting absorbents at the project sites, and are expected to be of significant help in the selection of precipitators that can collect total hydrocarbons for compliance of the emission standards.
0개의 논문이 장바구니에 담겼습니다.
선택하신 파일을 압축중입니다.
잠시만 기다려 주십시오.