C-arm 알루미늄 악세사리 사용에 따른 선량 비교
Comparison of exposure dose by use of C-arm Al accessory

첫 페이지 보기
  • 발행기관
    대한디지털의료영상학회 바로가기
  • 간행물
    대한디지털의료영상학회논문지 바로가기
  • 통권
    Volume 19 Number 1 (2017.10)바로가기
  • 페이지
    pp.27-31
  • 저자
    조재훈, 장성원, 우봉철, 허재, 김광민
  • 언어
    한국어(KOR)
  • URL
    https://www.earticle.net/Article/A483100

※ 기관로그인 시 무료 이용이 가능합니다.
※ 학술발표대회집, 워크숍 자료집 중 4페이지 이내 논문은 '요약'만 제공되는 경우가 있으니, 구매 전에 간행물명, 페이지 수 확인 부탁 드립니다.

4,000원

원문정보

초록

영어
Purpose : a research on reducing exposure dose of the operator was progressed by removing unnecessary X-ray and scattering rays being spread in radial shape by use of subsidiary accessory of C-arm. Material and method : Mobile type image amplification system (C-arm), doughnut-shaped aluminium with thickness of 2T of which inside is filled with powder type Barium and glass dosimeter, Phantom were used and by placing phantom on operation table, C-arm center in over tube condition was positioned on abdomen of phantom. At ringer stand being distanced from the center by 50cm, glass dosimeter was positioned at 160cm that is average eyeball location of adult male, 140cm that is location of thyroid and 50cm that is location of gonad, respectively and result value was analyzed by performing a test for 5 times in the same way as above while irradiating, measuring 90kVp, 5mAs for 1 minute in the order of non-used accessory, doughnut-shaped aluminium with thickness of 2T that circled tube to be matched with its size, doughnut-shaped aluminium of which inside is filled with Barium. Result : Non-used accessory was measured as 0.032mGy at eyeball position, 0.041mGy at thyroid position and 0.091mGy at gonad position, respectively. When covering Al, 0.027mGy at eyeball position, 0.031mGy at thyroid position and 0.083mGy at gonad position were measured respectively and this result showed that in eyeball, 15%, thyroid 20% and 8% in gonad were reduced. When filled Al cover inside with barium, 0.025mGy, 0.030mGy and 0.081mGy were measured in eyeball, thyroid and gonad respectively and it showed that in eyeball, 21%, thyroid 25% and 10% in gonad were reduced. Conclusion : By use of proper accessory, exposure dose of the operator could be reduced. In addition, consistent concern for reducing exposure dose shall be required through adequate distance, shortening of using time.

목차

Abstract
Ⅰ. 서론
Ⅱ. 대상 및 방법
1. 실험 기자재
2. 차폐용 기구 제작
3. 검사 방법
Ⅲ. 결과
1. eyeball
2. thyroid
3. gonad
Ⅳ. 고찰 및 결론
참고문헌

키워드

C-arm Dose reduction

저자

  • 조재훈 [ Jae-Hun Cho | 서울아산병원 영상의학팀 ]
  • 장성원 [ Seong-Won Jang | 서울아산병원 영상의학팀 ]
  • 우봉철 [ Bong-Chul Woo | 서울아산병원 영상의학팀 ]
  • 허재 [ Jae Huh | 서울아산병원 영상의학팀 ]
  • 김광민 [ Kwang-min Kim | 서울아산병원 영상의학팀 ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한디지털의료영상학회 [대한디지털의료영상학]
  • 설립연도
    1995
  • 분야
    의약학>방사선과학
  • 소개
    대한디지털의료영상학회는 디지털 영상 기술에 관한 연구와 실험 결과를 임상에 적용하여 영상의학 및 진단 방사선 기술 분야의 발전에 기여함을 목적으로 한다.

간행물

  • 간행물명
    대한디지털의료영상학회논문지 [Korean Journal of Digital Imaging in Medicine]
  • 간기
    연3회
  • pISSN
    1976-7641
  • 수록기간
    1995~2025
  • 십진분류
    KDC 510 DDC 610

이 권호 내 다른 논문 / 대한디지털의료영상학회논문지 Volume 19 Number 1

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장