투시 검사 시 체위 변화에 따른 입사표면선량의 평가 연구
An Evaluative Study on ESD(Entrance Surface Dose) by Posture Changes for Fluoroscopy

첫 페이지 보기
  • 발행기관
    대한디지털의료영상학회 바로가기
  • 간행물
    대한디지털의료영상학회논문지 바로가기
  • 통권
    Volume 13 Number 4 (2011.12)바로가기
  • 페이지
    pp.177-183
  • 저자
    양해두, 홍선숙, 박은성, 성민숙, 하동윤
  • 언어
    한국어(KOR)
  • URL
    https://www.earticle.net/Article/A483025

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

원문정보

초록

영어
This study intends to investigate patients’ exact exposure doses by comparatively measuring ESD (Entrance Surface Dose) with the DAP meter, which excludes scattered rays, and ESD with the Xi multifunction meter, which includes scattered rays, by posture changes for Esophagography test and UGI test. The materialwere examined through Sonialvision-SafireⅡ SPEC overtube system. ESD was measured by using the DAP meter, and as a tool to measure ESD including scattered rays on the plane of incidence of human phantom, the Xi multifunction meter was used. The average fluoroscopic time of Esophagography test was 4.192 minutes and the average number of images was 47.7, while the average fluoroscopic time of UGI test was 6.881 minutes and the average number of images was 37.8. The ratios of the incident dose of DAP meter and the ESD of Xi meter were calculated bydividing the fluoroscopic time and the number of images by each posture change. As for Esophagography test, the dose increased by 21.6~55.5% in the fluoroscopic test and by 4.8~24.7% in the spot test. In the front spot test, however, the does increased by as little as 5.3%. As for UGI test, the dose increased by 21.1~49.5% in the fluoroscopic test and by 10.1~34.9% in the spot test. It is expected that measuring doses in consideration of scattered rays by posture changes will be an important index in evaluating and managing patients’ exact exposure doses for each test above. Furthermore, it is judged that this sort of study is inevitable and desirable to reduce patients’ exposure doses after all.

목차

Abstract
Ⅰ. 서론
Ⅱ. 실험대상 및 방법
1. 실험장비 및 측정기기
2. 조사대상
3. 측정방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌

키워드

DAP meter ESD : Entrance Surface Dose Scattering rays

저자

  • 양해두 [ Hae Doo Yang | 서울아산병원 영상의학팀 ] Corresponding Author
  • 홍선숙 [ Seon Sook Hong | 서울아산병원 영상의학팀 ]
  • 박은성 [ Eun Seong Park | 서울아산병원 영상의학팀 ]
  • 성민숙 [ Min Sook Seong | 서울아산병원 영상의학팀 ]
  • 하동윤 [ Dong Yoon Ha | 서울아산병원 영상의학팀 ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한디지털의료영상학회 [대한디지털의료영상학]
  • 설립연도
    1995
  • 분야
    의약학>방사선과학
  • 소개
    대한디지털의료영상학회는 디지털 영상 기술에 관한 연구와 실험 결과를 임상에 적용하여 영상의학 및 진단 방사선 기술 분야의 발전에 기여함을 목적으로 한다.

간행물

  • 간행물명
    대한디지털의료영상학회논문지 [Korean Journal of Digital Imaging in Medicine]
  • 간기
    연3회
  • pISSN
    1976-7641
  • 수록기간
    1995~2025
  • 십진분류
    KDC 510 DDC 610

이 권호 내 다른 논문 / 대한디지털의료영상학회논문지 Volume 13 Number 4

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장