Non Breathe Hold Technique룰 이용한 MR 담도계조영술에 대한 고찰 : Prospective Acquisition Correction (PACE) 기법과 Respiration Trigger Gating(RTG) 기법의 비교
A Study on MR Cholangiography using Breathing Hold Target Techniqu by Prospective Acquisition Correction and Respiration Trigger Gating

첫 페이지 보기
  • 발행기관
    대한디지털의료영상학회 바로가기
  • 간행물
    대한디지털의료영상학회논문지 바로가기
  • 통권
    Volume 10 Number 1 (2008.05)바로가기
  • 페이지
    pp.45-50
  • 저자
    구은회, 정홍량, 임청환, 권대철, 조정근, 이만구
  • 언어
    한국어(KOR)
  • URL
    https://www.earticle.net/Article/A482951

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

원문정보

초록

영어
Recently, MR Cholangiography used mainly by controlling of patient's breathing. There is breathing hold techniques to get images within short 仕me and gating technique adjusted to respiration cycle for high resolution images. In this study, the aim of this experiment is to know on clinical usefulness compared with PACE and RTG techniques. This study's period is from 2006 in November to 2007 in January. A total of 21 patients investigated at MAGNETOM Sonata 1.5T (SIEMENS Erlangen) with use of 12ch body coil. MR acquisition protocol used 3D turbo spin echo coronal sequence. Scan parameters applied to optimal setting in use as gating techniques, respectively. Analysis of consuming timing evaluated with rapidness. As analysis of quantity, the common bile duct, gall bladder measured in signal intensities, then these data were calculated by signal to noise ratio and contrast to noise ra仕o. Qualitative analysis, experienced 2radiologists and 3 RTs were evaluated into 3groups about artifact, accuracy of lesions, sharpness of the common bile duct or gall bladder. As a result of analysis, when compared to PACE, consuming time of the RTG took less than PACE. On both CNRs and SNRs, PACE technique was slightly high values than RTG(p<0.05). Qualitative analysis' results, discrimination of lesions in the common bile duct, gall bladder get a significance level in both RTG and PACE techniques but presences artifact of breathing and pulsation highly demonstrate in PACE techniques. In conclusion, both PACE and RTG methods at MRCP provided prominently clinical information for the common bile duct, gall bladder. If machines have not limitation with performance, induction of breathing holding also will help getting diagnos仕c quality.

목차

Abstract
I. 서론
II. 대상 및 방법
1. 검사방법
2. 분석 방법
III. 결과
IV. 결론
참고문헌

저자

  • 구은회 [ Goo, Eun-Hoe | 서울대학교병원 영상의학과 ] 책임저자
  • 정홍량 [ Jeong, Hong-Ryang | 한서대학교 방사선학과 ]
  • 임청환 [ IM, Cheong-Hwan | 한서대학교 방사선학과 ]
  • 권대철 [ Kweon, Dae-Cheol | 신흥대학 방사선과 ]
  • 조정근 [ Jo, Jeong-Keun | 전주대학교 방사선학과 ]
  • 이만구 [ Lee, Man-Koo | 원광보건대학 방사선과 ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한디지털의료영상학회 [대한디지털의료영상학]
  • 설립연도
    1995
  • 분야
    의약학>방사선과학
  • 소개
    대한디지털의료영상학회는 디지털 영상 기술에 관한 연구와 실험 결과를 임상에 적용하여 영상의학 및 진단 방사선 기술 분야의 발전에 기여함을 목적으로 한다.

간행물

  • 간행물명
    대한디지털의료영상학회논문지 [Korean Journal of Digital Imaging in Medicine]
  • 간기
    연3회
  • pISSN
    1976-7641
  • 수록기간
    1995~2026
  • 십진분류
    KDC 510 DDC 610

이 권호 내 다른 논문 / 대한디지털의료영상학회논문지 Volume 10 Number 1

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장