The purpose of this study is to analyze the thermal of an office building, as well as the external louver shade scheme suitable for windows in various directions of the building in different climate divisions in China. The results are as follows: In Lanzhou, dimming control has little effect on lighting energy consumption. Therefore, when the horizontal louver has a blade width of 120mm, the spacing 300mm, and the angle in the west is 30°-45°, the angle in the south is 75°-90° the energy saving effect is proved, and the building's discomfort glare of the building can be reduced. Due to the small energy savings in the east direction, it is not economically feasible to set fixed external louver for shading. Setting a fixed external shade is thought to be more appropriate. In Chongqing, the energy saving effect of cooling and heating load, the block effect of discomfort glare is good when horizontal louvers are set in the west direction with the blade width 500mm, the spacing 500mm, and the angle 15°-45°, as well as when horizontal louvers are set in the east and south directions with the blade width 300mm, the spacing 500mm, and the angle 15°-45°. However, the setting of louver shade in the set of dimming control will have a great impact on the lighting energy consumption demand, so the total energy saving effect of the building is relatively small. In Shenzhen, When horizontal louvers are set in the east, west and south directions, with the blade width 500mm, the spacing 500mm, the east angle 15°-45°, and the west and south angle 30°-45°, the energy saving effect is enhanced, and the discomfort glare can be effectively avoided. However, when the dimming control is activated, the louver shade consumes more lighting energy, resulting in an increase in the total energy consumption.
목차
Abstract 1. 서론 1.1 연구의 배경 및 목적 1.2 연구의 범위 및 방법 2. 대상지역 선정 3. 수치시뮬레이션 입력조건 설정 3.1 해석모델 설정 및 경계조건 3.2 루버의 변수 설정 3.3 시뮬레이션 조건 3.4 조명제어와 현휘 입력조건 4. 기후구역별 루버 변수에 따른 에너지소요량 분석 4.1 루버 슬랫 각도 변수에 따른 에너지소요량 4.2 루버 슬랫 폭 변화에 따른 에너지소요량 4.3 루버 슬랫 간격 변화에 따른 에너지소요량 4.4 기후구역별 루버 변화에 따른 건물에너지 절감효과 5. 기후구역별 루버 슬랫 각도에 따른 빛환경 분석 5.1 불쾌 현휘의 평가지표 5.2 연간 불쾌 현휘 및 에너지소요량 6. 결론 REFERENCES
키워드
오피스건물외부차양 장치건물에너지저탄소저에너지Office BuildingExternal Shading DeviceBuilding EnergyLow CarbonLow Energy
대한건축학회지회연합회 [The Regional Association of Architectural Institute of Korea]
설립연도
2000
분야
공학>건축공학
소개
본회는 건축에 관한 학술․ 예술․ 기술을 연구 연마하는 지회회원들의 입지향상과 회원상호간의 친목도모와 함께 건축 문화창달에 기여함을 목적으로 한다.
목적을 달성하기 위하여 다음의 사업을 한다.
1. 지회회원의 입지향상과 친목도모
2. 건축에 관한 조사․연구지도 및 이에 관련된 사업
3. 회지, 논문집, 연구보고서 기타 건축에 관한 도서의 간행
4. 건축에 관한 강습회․강연회․간담회․전람회․견학회 등의 개최
5. 건축에 관한 계획, 감독, 기술검토에 대한 국가공공기관 기타의뢰에 관한 사항
6. 국내외 관계 제 학회와의 교류 및 회의참석
7. 기타 본회 목적달성에 필요한 사업
간행물
간행물명
대한건축학회연합논문집 [Journal of the Regional Association of Architectural Institute of Korea]