환경영향 범주 평가를 위한 등급 설정 - 레미콘 제품 생산을 중심으로 -
Establishment of the Interval Rating of the Environmental Categories’Assessment - Focused on the REMICON(Ready Mixed Concrete Product) -
Evaluation or assessment is important to understand the policy fulfillment and system improvement. The evaluation process would include the objective judgment and a yardstick for judgment. This process meets the system and policy fulfillment, guaranteeing that the decision-making is good and understandable. Recently, the environmental affect to global area is has become urgently serious for global warming, acidification, ozone depletion, eutrophication and so on. Building industries try to mitigate the global affect with the development of the environmental friendly materials and components, by implementing the policy to protect the nature. Among these, the G-SEED would carry a role to evaluate the building level for the environment. The G-SEED would obviously execute an important role to provide the environmental oriented building, however, its evaluation sheet can’t may not provide the objective and quantitative contents. Results of evaluation would imply an mistake to forecast the full evaluation process. Therefore, the evaluation contents need a correct indication and explanation. In this paper, it aims to provide the evaluation rating of the environmental affect in order to to explain the affect level by unit product(m3) in REMICON. The environmental affect factors are the resources footprint, global warming, acidification, ozone depletion, eutrophication and photochemical oxidation. Results of this study are as follows: First, the level of the environmental affect can be explained with an normal probability distribution and divided with 5-steps, which scale of interval has a same 20%. Second, the 1st rating of resources footprint should has be under the 0.867089666 kg Sb-eq./m3, global warming potential of under 224.880063 kg CO2-eq./m3, the ozone depletion of under 0.542733 kg CFC-11-eq./m3, the acidification of under 0.310035 ㎏ SO2-eq./m3, eutrophication of under 0.037336 kg PO43—eq./m3 and photochemical oxidation of under 0.172168 kgC2H4—eq./m3. Third, among 5-steps, the Ⅲ rating has a narrow interval because each rating has a same frequency.
목차
Abstract 1. 서론 1.1 연구배경 및 목적 1.2 연구방법과 내용 2. 평가등급 설정관련 기존 문헌 3. 환경영향 평가등급 설정 3.1 평가등급 설정방법 3.2 분석결과 4. 결론 REFERENCES
대한건축학회지회연합회 [The Regional Association of Architectural Institute of Korea]
설립연도
2000
분야
공학>건축공학
소개
본회는 건축에 관한 학술․ 예술․ 기술을 연구 연마하는 지회회원들의 입지향상과 회원상호간의 친목도모와 함께 건축 문화창달에 기여함을 목적으로 한다.
목적을 달성하기 위하여 다음의 사업을 한다.
1. 지회회원의 입지향상과 친목도모
2. 건축에 관한 조사․연구지도 및 이에 관련된 사업
3. 회지, 논문집, 연구보고서 기타 건축에 관한 도서의 간행
4. 건축에 관한 강습회․강연회․간담회․전람회․견학회 등의 개최
5. 건축에 관한 계획, 감독, 기술검토에 대한 국가공공기관 기타의뢰에 관한 사항
6. 국내외 관계 제 학회와의 교류 및 회의참석
7. 기타 본회 목적달성에 필요한 사업
간행물
간행물명
대한건축학회연합논문집 [Journal of the Regional Association of Architectural Institute of Korea]