Sun Kun, Wang Jing, Wang Hongchao, Yu Limei, Li Chenyang, Zhang Xiaowen
언어
영어(ENG)
URL
https://www.earticle.net/Article/A235173
※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.
원문정보
초록
영어
The non-source temperature calibration method of the multi-spectral pyrometer (MSP), put forward in the previous article, is the non-source calibration method based on the MSP transfer function (NCCTF). In this paper, the practicability of NCCTF is researched. The situations that maybe encountered of the temperature points in the actual calibration process are simulated. The impact of the intervals temperature points of different number and unequal intervals temperature points on the NCCTF accuracy are researched theoretically to determine the temperature points select method. Simulation experimental results show that the NCCTF can meet the actual calibration process with good usability.
목차
Abstract 1. Introduction 2. Measurement Principle 3. The Selection of the Temperature Points 3.1. Different Number of Intervals Temperature Points 3.2. Unequal Intervals Temperature Points 4. Conclusion Acknowledgments References
키워드
High-temperature measurementNon-source temperature calibrationDerivative extrapolationTemperature points selection
저자
Sun Kun [ The Higher Educational Key Laboratory for Measuring & Control Technology and Instrumentations of Heilongjiang Province, Harbin University of Science and Technology, Harbin, China ]
Wang Jing [ The Higher Educational Key Laboratory for Measuring & Control Technology and Instrumentations of Heilongjiang Province, Harbin University of Science and Technology, Harbin, China ]
Wang Hongchao [ The Higher Educational Key Laboratory for Measuring & Control Technology and Instrumentations of Heilongjiang Province, Harbin University of Science and Technology, Harbin, China ]
Yu Limei [ The Higher Educational Key Laboratory for Measuring & Control Technology and Instrumentations of Heilongjiang Province, Harbin University of Science and Technology, Harbin, China ]
Li Chenyang [ The Higher Educational Key Laboratory for Measuring & Control Technology and Instrumentations of Heilongjiang Province, Harbin University of Science and Technology, Harbin, China ]
Zhang Xiaowen [ The Higher Educational Key Laboratory for Measuring & Control Technology and Instrumentations of Heilongjiang Province, Harbin University of Science and Technology, Harbin, China ]
보안공학연구지원센터(IJCA) [Science & Engineering Research Support Center, Republic of Korea(IJCA)]
설립연도
2006
분야
공학>컴퓨터학
소개
1. 보안공학에 대한 각종 조사 및 연구
2. 보안공학에 대한 응용기술 연구 및 발표
3. 보안공학에 관한 각종 학술 발표회 및 전시회 개최
4. 보안공학 기술의 상호 협조 및 정보교환
5. 보안공학에 관한 표준화 사업 및 규격의 제정
6. 보안공학에 관한 산학연 협동의 증진
7. 국제적 학술 교류 및 기술 협력
8. 보안공학에 관한 논문지 발간
9. 기타 본 회 목적 달성에 필요한 사업
간행물
간행물명
International Journal of Control and Automation
간기
월간
pISSN
2005-4297
수록기간
2008~2016
십진분류
KDC 505DDC 605
이 권호 내 다른 논문 / International Journal of Control and Automation Vol.7 No.11