In this paper, we analyze the conducted noise level of a long cable considering a subsea environment. Because conducted noise causes distortion for a signal and power line, it must be removed. As it have a negative effect on system reliability. Thus, we analyzed the effects of the conducted noise, which is caused by the temperature at the depth of the sea. To design conducted noise, we transformed the effect of the temperature changes influencing the cable into an equivalent circuit, and co-simulated it with FEM (finite element model) tools. This method allowed us to propose a proper design method for a long cable and determine the relationship between the noise and temperature.
목차
Abstract 1. Introduction 2. Analysis of Factors Acting on Cables 2.1 Occurrence of Transient Voltage 2.2 Capacitance Change with Respect to Temperature 3. Simulation of Temperature Change in Cables 3.1 Configuration of the Thermal System 3.2 Cable Modeling 4. Simulation and Results 5. Conclusion Acknowledgments References
저자
Seung-Jae Ryu [ Graduate School of Electrical Engineering, University of Ulsan, Ulsan, Korea ]
Byeong-Woo Kim [ Dept. of Electrical Engineering, University of Ulsan, Ulsan, Korea ]
보안공학연구지원센터(IJCA) [Science & Engineering Research Support Center, Republic of Korea(IJCA)]
설립연도
2006
분야
공학>컴퓨터학
소개
1. 보안공학에 대한 각종 조사 및 연구
2. 보안공학에 대한 응용기술 연구 및 발표
3. 보안공학에 관한 각종 학술 발표회 및 전시회 개최
4. 보안공학 기술의 상호 협조 및 정보교환
5. 보안공학에 관한 표준화 사업 및 규격의 제정
6. 보안공학에 관한 산학연 협동의 증진
7. 국제적 학술 교류 및 기술 협력
8. 보안공학에 관한 논문지 발간
9. 기타 본 회 목적 달성에 필요한 사업
간행물
간행물명
International Journal of Control and Automation
간기
월간
pISSN
2005-4297
수록기간
2008~2016
십진분류
KDC 505DDC 605
이 권호 내 다른 논문 / International Journal of Control and Automation Vol.7 No.5