The purpose of this study is to investigate the relationship between radiation origin and health professionals, and to reduce exposed dose of radiation through efficient management. Increasing exposed dose of radiation to health professionals are caused by the increase of PET/CT use and a radioactive isotope. Hence, in this study, space dose from each origin of radiation generating was analyzed and the use of personnel protective clothing and shields was compared. As a result of this study, we confirmed that the exposed dose of radiation was much higher in case of wearing personnel protective clothing(0.5 mm pb) than no wearing personnel protective clothing under high energy gamma radiation(511 keV) of the position emitter(18F).
한국어
본 연구의 목적은 PET/CT 검사시 공간선량을 측정 비교함으로써 방사선 발생원과 종사자간 선량의 상관관계를 규명하고 효율적인 관리를 통해 피폭선량을 감소시키는데 있다. 최근 PET/CT 검사의 증가는 동위원소 사용량의 증가와 더불어 종사자의 피폭 증가의 원인이 되고 있다. 따라서 각 방사선 발생원에서의 공간선량을 비교 분석하고 개인방호복과 차폐체 사용에 관한 연구를 수행하였다. 양전자 방출핵종인 18F 방출 감마선 고에너지(511 keV)에서 개인방호복(0.5 mm pb) 사용은 미사용 시 보다 더 많은 피폭을 초래함을 확인하였다.
목차
요약 Abstract 1. 서론 2. 실험재료 및 방법 2.1 장비 및 사용도구 2.2 실험방법 2.3 분석방법 3. 결과 3.1 약품분배실 공간선량률 3.2 실험결과 4. 고찰 및 결론 참고문헌