년 - 년
철골 구조물 접합부 고정장치(파스너)에 관한 연구 KCI 등재
대한건축학회지회연합회 대한건축학회연합논문집 제24권 제4호 통권 110호 2022.08 pp.31-38
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
This study is a basic study on the fixing device(Fastener) of the steel structure joint.Four types of T.S. Nut specimens were manufactured and tested. A total of 20 specimens were produced, 5 each. When manufacturing T.S. Nut, the existing long nut was used, and it was manufactured by precision machining so that the T.S. Nut head shear cross section could be cut. In order to reduce material deterioration due to heat that may occur during rotary cutting, cutting oil is used and low-speed machining is applied. The thickness parameter ranged from 0.5mm to 1.25mm. The clamping force(N) and the torque value(T) of the hexagonal high-strength bolt changes according to the shear sectional thickness(a) of the T.S Nut head. Clamping force(N), torque values(T) and torque coefficient(k) were analyzed to examine whether thickness variables affect the required tensile strength. As a result of the analysis, the clamping force(N) and the torque value(T) increased as a whole according to the shear sectional thickness(a) of the T.S. Nut head. In addition, in the case of T.S. Nut head shear thickness(a) 0.5mm to 1.0mm, the difference in torque coefficient(k) was similarly 103% to 105%, so it was found to be sufficiently stable.
차량 시트 레일용 리드 스크류의 동역학적 해석을 통한 회전 토크 값 분석 연구 KCI 등재
한국기계항공기술학회(구 한국기계기술학회) 한국기계항공기술학회지(구 한국기계기술학회지) 제25권 제5호 2023.10 pp.792-801
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
The objective of this study is to analyze the difference between the theoretically calculated torque values of lead screws used in vehicle seat rails and the required torque values due to various disturbances that occur in actual systems. Lead screws were classified into square and trapezoidal threads and modeled by two lead type. Dynamic analysis models were constructed by applying contact conditions and rotational joints between the lead screw and nut. The validity of the dynamic model was verified by comparing the torque values obtained from rigid body dynamic analysis with the theoretically calculated torque values. Then, the lead screw was modeled as a flexible body to investigate the torque variation required for the lead screw when dynamic loads are considered. This study will help predict the actual torque values of lead screws for seat rails.
[Kisti 연계] 대한치과교정학회 KJO : Korean journal of orthodontics Vol.41 No.4 2011 pp.280-287
※ 협약을 통해 무료로 제공되는 자료로, 원문이용 방식은 연계기관의 정책을 따르고 있습니다.
Objective: This study compared the stability of cylindrical miniscrews (Cy, 7 mm in length) with that of tapered miniscrews (Ta, 5 mm in length), using torque values to determine if the healing time before loading affects the stability of the miniscrew and if the insertion torque is associated with the removal torque measured after a few weeks of healing. Methods: Ta and Cy with different thread lengths were placed in the tibias of 12 female New Zealand white rabbits (body weight: 3.0 - 3.5 kg), and the maximum insertion torque values (ITV) were measured. No orthodontic forces were applied so as to allow us to determine the pure effects of the different shapes. After 3 different healing periods (2, 4, and 6 weeks), maximum removal torque values (RTV) were measured immediately before the rabbits were sacrificed. Results: No miniscrews were loosened. There were no significant differences in ITV or RTV between the Ta and Cy nor were there any significant differences in the ITV and RTV between the 3 groups, which had different healing periods. There was a correlation between the ITV and RTV. Conclusions: Shorter Ta showed similar stability as Cy, as determined by torque values. This result strongly suggests that the tapered shape is more advantageous than the cylindrical shape. The RTV did not increase significantly over time. It is recommended that a miniscrew be loaded immediately; waiting a few weeks before loading should be avoided. The correlation between the ITV and RTV suggests that the ITV can be used to estimate a screw's future stability.
A STUDY ON THE CORRELATION BETWEEN IMPLANT STABILITY VALUES AND INITIAL INSERTION TORQUE
[Kisti 연계] 대한치과보철학회 대한치과보철학회지 Vol.44 No.3 2006 pp.314-324
※ 협약을 통해 무료로 제공되는 자료로, 원문이용 방식은 연계기관의 정책을 따르고 있습니다.
Statement of problem. Osseointegration is important mechanism of dental implant but it is not easy to evaluate. Indirect measurement is non-invasive and clinically applicable but they need more study about correlation between indirect values and degree of osseointegration. Purpose. The aims of this study were to evaluate the coefficient of correlation between indirect measurement and direct measurement under different healing time, and assessment of effect of initial insertion torque to the implant stability. Material and Methods. 20 rabbits received 3 implants on each side of tibia. Three kinds of implants (machined surface implant, Sandblasted with Large grit and Acid etched implant, Resorbable Blast Media treated implant) were used. During the surgery implant insertion torque were measured with $Osseocare^{TM}$. After the 1, 4, 8, 12 weeks of healing time, animals were sacrificed and stability values (Implant Stability Quotient with $Osstell^{TM}$, removal torque with torque gauge) were measured. Results. The Bone quality of rabbit tibia was classified into 2 groups according to the insertion torque. Resonance frequency analysis (ISQ) and removal torque showed positive correlation until $4^{th}$ week (r=0.555, p=0.040). After $8^{th}$ week (r=0.011, p=0.970) the correlation became weak and it turned negative at $12^{th}$ week (r=-0.074, p=0.801). Insertion torque and ISQ showed changing correlation upon the healing time ($1^{st}$ week: r=0.301, p=0.033, $4^{th}$ week: r=-0.429, p=0.018, $8^{th}$ week: r=0.032, p=0.865, $12^{th}$ week: r=-0.398, p=0.029). Insertion torque and removal torque has positive correlation but it was not statistically significant ($1^{st}$ week: r=0.410, p=0.129, $4^{th}$ week: r=0.156, p=0.578, $8^{th}$ week: r=0.236, p=0.398, $12^{th}$ week: r=0.260, p=0.350). Conclusion. In this study, bone quality may affect the degree of osseointegration positively during healing time and correlation between ISQ and degree of osseointegration can be different according to the healing time and bone quality.
[Kisti 연계] 한국자기학회 한국자기학회 학술대회논문집 1998 pp.106-107
※ 협약을 통해 무료로 제공되는 자료로, 원문이용 방식은 연계기관의 정책을 따르고 있습니다.
0개의 논문이 장바구니에 담겼습니다.
선택하신 파일을 압축중입니다.
잠시만 기다려 주십시오.