년 - 년
A Novel Iris Authentication Using ECDSA SCOPUS
보안공학연구지원센터(IJSIA) International Journal of Security and Its Applications Vol.10 No.1 2016.01 pp.119-124
※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.
The Cryptographic systems need a secret key or a random number must be necessarily tied to an individual through a unique identifier. This unique identifier definitely might exist a globally user id or biometric data [2]. In this paper we combined biometric with cryptography in which the intensity of each pixel of iris is changed into the elliptic curve and encrypted using ECC. The receiver end original image is recovered by using their decryption and authentication [8] is performed using ECDSA. The proposed technique is implemented for BMP images. We can enroll and add the number of images for authentication .It has been also performed more security if the image is recovered without being any side channel attack.
IRIS형 방사선검출기 콜리메이터 제작 및 MCNP 코드를 이용한 성능평가 KCI 등재
한국방사성폐기물학회 방사성폐기물학회지 Volume 13 Number 1 2015.03 pp.55-61
※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.
방사선검출기를 이용한 고방사성물질의 측정이나 방사선사고 등의 신속한 대응을 위하여 주위의 선량률 준위에 따라 크기별로 여러 종류의 콜리메이터들을 구비해야 하며, 이는 무거운 콜리메이터의 특성상 효율적인 현장 측정에 심각한 장애가될 수 있다. 본 연구에서는 콜리메이터의 모양을 카메라의 렌즈 조리개 형식으로 제작하여 사용자가 직접 카메라 렌즈를 돌려 초점을 맞추듯이 콜리메이터의 내경을 조절하고 방사선의 감쇄율을 쉽게 알아볼 수 있도록 IRIS형 콜리메이터를 제작하였다. 먼저, 콜리메이터를 위상을 달리한 2 중의 텅스텐 셔터 구조로 제작하여 기계적 공차에 의한 방사선의 침투를 차단하고자 하였다. 그리고 셔터의 재질별로 콜리메이터 내경에 따른 방사선 감쇄율을 MCNP 코드를 이용하여 계산함으로써 이론적인 성능평가를 수행하였다. 계산된 내경의 크기별 감쇄율을 콜리메이터 외부 눈금링에 표시함으로써, 카메라 렌즈에 표시된 배율과 같은 방법으로 사용자가 해당 표시지점으로 콜리메이터 내경을 조절하였을 때, 방사선의 세기가 얼마만 큼 감소되는지 쉽게 알아볼 수 있도록 구현하였다. 끝으로 개발된 IRIS형 콜리메이터를 장착한 소형 방사선검출기를 현장 측정에 활용할 경우, 콜리메이터의 교체 없이 주위 방사선의 세기에 따라 콜리메이터 내경을 적절한 크기로 신속히 교체가 가능하며,방사선 세기의 감쇄 정도를 쉽게 알아보게 함으로써 신속하고 정확한 대처가 가능할 것으로 판단된다.
When a radiation detector is applied to the measurement of the radioactivity of high-level of radioactive materials or therapid response to the nuclear accident, several collimators with the different inner radii should be prepared according tothe level of dose rate. This makes the in-situ measurement impractical, because of the heavy weight of the collimator. Inthis study, an IRIS collimator was developed so as to have a function of controlling the inner radius, with the same methodused in optical camera, to vary the attenuation ratio of radiation. The shutter was made to have the double tungsten layerswith different phase angles to prevent the radiation from penetrating owing to the mechanical tolerance. The performanceevaluation through the MCNP code was conducted by calculating the attenuation ratio according to the inner radius of thecollimator. The attenuation ratio was marked on the outer scale ring of the collimator. It is expected that when a radiationdetector with the IRIS collimator is used for the in-situ measurement, it can change the attenuation ratio of the incidentphoton to the detector without replacing the collimator.
Iris Code Construction for Human Identification
[Kisti 연계] 대한의용생체공학회 의공학회지 Vol.25 No.1 2004 pp.83-86
※ 협약을 통해 무료로 제공되는 자료로, 원문이용 방식은 연계기관의 정책을 따르고 있습니다.
The variation of the directional properties of an image is used to extract the iris code for human identification. In order to conserve the original information while minimizing the effect of noise, scale-space filtering is applied. Resulting binary codes have been tested on a set of 272 iris images obtained from 18 persons.
퍼지볼트 기반의 암호 키 생성을 위한 불변 홍채코드 추출
[Kisti 연계] 대한전자공학회 대한전자공학회 학술대회논문집 2006 pp.321-322
※ 협약을 통해 무료로 제공되는 자료로, 원문이용 방식은 연계기관의 정책을 따르고 있습니다.
In this paper, we propose a method that extracts invariant iris codes from user's iris pattern in order to apply these codes to a new cryptographic construct called fuzzy vault. The fuzzy vault, proposed by Juels and Sudan, has been used to manage cryptographic key safely by merging with biometrics. Generally, iris data has intra-variation of iris pattern according to sensed environmental changes, but cryptography requires correctness. Therefore, to combine iris data and fuzzy vault, we have to extract an invariant iris feature from iris pattern. In this paper, we obtain invariant iris codes by clustering iris features extracted by independent component analysis(ICA) transform. From experimental results, we proved that the iris codes extracted by our method are invariant to sensed environmental changes and can be used in fuzzy vault.
[Kisti 연계] 대한전자공학회 대한전자공학회 학술대회논문집 2005 pp.1011-1014
※ 협약을 통해 무료로 제공되는 자료로, 원문이용 방식은 연계기관의 정책을 따르고 있습니다.
In this paper, we propose a method that extracts an invariant biometric key in order to apply this biometric key to the crypto-biometric system. This system is a new authentication architecture which can improve the security of current cryptographic system and solve the problem of stored template protection in conventional biometric system, also. To use biometric information as a cryptographic key in crypto-biometric system, same key should be generated from the same person. However, it is difficult to obtain such an invariant biometric key because biometric data is sensitive to surrounding environments. The proposed method solves this problem by clustering Iris Codes obtained by using independent component analysis (ICA).
IRIS형 방사선검출기 콜리메이터 제작 및 MCNP 코드를 이용한 성능평가
[Kisti 연계] 한국방사성폐기물학회 Journal of Nuclear Fuel Cycle and Waste Technology Vol.13 No.1 2015 pp.55-61
※ 협약을 통해 무료로 제공되는 자료로, 원문이용 방식은 연계기관의 정책을 따르고 있습니다.
방사선검출기를 이용한 고방사성물질의 측정이나 방사선사고 등의 신속한 대응을 위하여 주위의 선량률 준위에 따라 크기별로 여러 종류의 콜리메이터들을 구비해야 하며, 이는 무거운 콜리메이터의 특성상 효율적인 현장 측정에 심각한 장애가 될 수 있다. 본 연구에서는 콜리메이터의 모양을 카메라의 렌즈 조리개 형식으로 제작하여 사용자가 직접 카메라 렌즈를 돌려 초점을 맞추듯이 콜리메이터의 내경을 조절하고 방사선의 감쇄율을 쉽게 알아볼 수 있도록 IRIS형 콜리메이터를 제작하였다. 먼저, 콜리메이터를 위상을 달리한 2 중의 텅스텐 셔터 구조로 제작하여 기계적 공차에 의한 방사선의 침투를 차단하고자 하였다. 그리고 셔터의 재질별로 콜리메이터 내경에 따른 방사선 감쇄율을 MCNP 코드를 이용하여 계산함으로써 이론적인 성능평가를 수행하였다. 계산된 내경의 크기별 감쇄율을 콜리메이터 외부 눈금링에 표시함으로써, 카메라 렌즈에 표시된 배율과 같은 방법으로 사용자가 해당 표시지점으로 콜리메이터 내경을 조절하였을 때, 방사선의 세기가 얼마만 큼 감소되는지 쉽게 알아볼 수 있도록 구현하였다. 끝으로 개발된 IRIS형 콜리메이터를 장착한 소형 방사선검출기를 현장 측정에 활용할 경우, 콜리메이터의 교체 없이 주위 방사선의 세기에 따라 콜리메이터 내경을 적절한 크기로 신속히 교체가 가능하며, 방사선 세기의 감쇄 정도를 쉽게 알아보게 함으로써 신속하고 정확한 대처가 가능할 것으로 판단된다.
When a radiation detector is applied to the measurement of the radioactivity of high-level of radioactive materials or the rapid response to the nuclear accident, several collimators with the different inner radii should be prepared according to the level of dose rate. This makes the in-situ measurement impractical, because of the heavy weight of the collimator. In this study, an IRIS collimator was developed so as to have a function of controlling the inner radius, with the same method used in optical camera, to vary the attenuation ratio of radiation. The shutter was made to have the double tungsten layers with different phase angles to prevent the radiation from penetrating owing to the mechanical tolerance. The performance evaluation through the MCNP code was conducted by calculating the attenuation ratio according to the inner radius of the collimator. The attenuation ratio was marked on the outer scale ring of the collimator. It is expected that when a radiation detector with the IRIS collimator is used for the in-situ measurement, it can change the attenuation ratio of the incident photon to the detector without replacing the collimator.
0개의 논문이 장바구니에 담겼습니다.
선택하신 파일을 압축중입니다.
잠시만 기다려 주십시오.