Earticle

현재 위치 Home 검색결과

결과 내 검색

발행연도

-

학문분야

자료유형

간행물

검색결과

검색조건
검색결과 : 3
No
1

4,000원

In this study, infrared thermometry techniques were used to conduct surface wetting performance tests (wicking tests) on micropillar structures with good fluid supply capabilities to enhance the critical heat flux. Wicking tests were conducted based on various micropillar shapes (i.e., diameter and spacing) to investigate the surface wetting performance near the boiling point of the fluid(~100°C). The surface temperature was increased from 20°C to 95°C, to examine the wicking performance The shape of the micropillars were quantified by the roughness and the effect of the roughness and temperature on the wicking performance was analyzed. As a result, we confirmed that the roughness of the micropillars increases the capillary pressure, improving the wicking performance. The sample D04 G10 with the highest roughness coefficient at room temperature (r=2.51) exhibited the highest wicking coefficient, showing a 170% improvement in wicking performance compared to D04G20 with the smallest roughness coefficient at room temperature(r=1.51). Additionally, the D04 G10 sample (r=2.51) recorded a 50% improvement in the wicking coefficient at the highest temperature(95°C) compared to room temperature(20°C). The wicking coefficient data will be utilized as a database for developing a new correlation for critical heat flux.

2

Comparison of Rectal and Infrared Thermometry for Obtaining Body Temperature of Gnotobiotic Piglets in Conventional Portable Germ Free Facility

Chung, Tae-Ho, Jung, Woo-Sung, Nam, Eui-Hwa, Kim, Ji-Hyun, Park, Seol-Hee, Hwang, Cheol-Yong

[Kisti 연계] 아세아태평양축산학회 Asian-Australasian journal of animal sciences Vol.23 No.10 2010 pp.1364-1368

※ 협약을 통해 무료로 제공되는 자료로, 원문이용 방식은 연계기관의 정책을 따르고 있습니다.

원문보기

Gnotobiotic piglets (n = 10) were hand-reared in conventional germ-free facilities. Piglet body temperatures were measured with rectal and non-contact infrared thermometry (NIFT) on the lower eyelid, auricular center and margin, parietal regions, axilla, central abdomen and dorsum, and the perianal region. Body temperature measurements at central abdomen, cranial dorsum, and perianal regions had NIFT values which had a significant linear relationship (p<0.0001) with rectal thermometry. The predicted equations of between-subject formulas were calculated as follows: rectal temperature, 28.07489+0.30372${\times}$central abdominal surface temperature; rectal temperature, 34.02799+0.15197${\times}$central dorsum surface temperature; and rectal temperature, 33.87937+0.15676${\times}$perianal temperature. These results suggested that NIFT could serve as a valid alternative to rectal thermometry in a portable germ-free facility without disturbing experimental animals. The development of a NIFT body temperature evaluation that does not require animal restraint is clinically advantageous, particularly in gnotobiotic piglets, and would be significantly less stressful for experimental procedures in germ-free facilities.

3

열화상 카메라를 이용한 원통형 물체의 온도측정

정덕운, 김경석, 정현철, 김동수, 양성모

[Kisti 연계] 한국정밀공학회 한국정밀공학회 학술대회논문집 2009 pp.525-526

※ 협약을 통해 무료로 제공되는 자료로, 원문이용 방식은 연계기관의 정책을 따르고 있습니다.

 
페이지 저장