년 - 년
대한안전경영과학회 대한안전경영과학회 학술대회논문집 2015년 대한안전경영과학회 춘계학술대회 2015.04 pp.381-386
※ 기관로그인 시 무료 이용이 가능합니다.
4,000원
This research presents efficient use of coverage factor of expanded uncertainty. Process Capability Indexes(PCIs) are newly introduced in this paper to take in consideration of either including correction and uncertainty of calibration or not for deciding bilateral specification, upper specificand and lower specification.
4,000원
This paper presents real examples of quality statistics for users to easily understand the concept and purpose for obtaining the degree of freedom. Moreover degree of freedom by Satterwaite can be used for linear combinations of unbiased variance. Finally effective degree of freedom by Welch-Satterthwaite is applicable to obtain expanded uncertainty considering type A and type B uncertainty.
4,300원
This paper is to propose model classification and evaluation of measurement uncertainty. In order to obtain type A and B uncertainty, variety of measurement mathematical models are illustrated by example. The four steps to evaluate expanded uncertainty are indicated as following; First, to get type A standard uncertainty, measurement mathematical models of single, double, multiple, design of experiment and serial autocorrelation are shown. Second, to solve type B standard uncertainty measurement mathematical models of empirical probability distributions and multivariate are presented. Third, type A and B combined uncertainty, considering sensitivity coefficient, linearity and correlation are discussed. Lastly, expanded uncertainty, considering degree of freedom for type A, B uncertainty and coverage factor are presented with uncertainty budget. SPC control chart to control expanded uncertainty is shown.
[NRF 연계] 대한재활의학회 Annals of Rehabilitation Medicine Vol.46 No.1 2022.02 pp.9-23
※ 협약을 통해 무료로 제공되는 자료로, 원문이용 방식은 연계기관의 정책을 따르고 있습니다.
Objective To develop a set of reference standards for tibial motor, common peroneal motor, sural sensory, and superficial peroneal sensory nerve conduction studies (NCSs) with expanded uncertainty in a healthy Korean population.Methods Standardized procedures were conducted for individual lower extremity NCSs of 199 healthy participants in their 20s (n=100) and 50s (n=99). Mean values and expanded uncertainties for parameters were analyzed with thorough consideration of multiple uncertainty factors under the International Guide to the Expression of Uncertainty in Measurement. In addition, side-to-side differences in onset latency, amplitude, and nerve conduction velocity (NCV) were analyzed.Results Mean (reference range) for distal onset latency, baseline to negative peak amplitude, NCV of tibial motor nerve in males in their 20s were 4.3 ms (3.1?5.4 ms), 7.1 mV (3.4?10.9 mV), and 50.7 m/s (42.2?59.3 m/s), respectively; sural sensory nerve baseline to negative peak amplitude in males in their 20s was 21.7 μV (8.3?35.2 μV). Including the aforementioned data, we present a vast dataset of normative mean values and expanded uncertainties for NCSs of the leg in a healthy Korean population. Furthermore, upper limits for normal side-to-side differences for onset latency, amplitude, and NCV of each nerve are suggested.Conclusion To our knowledge, this is the first study to present the reference standards of leg NCSs with consideration for multifactorial uncertainties in an Asian population. We expect these results to help practitioners make reliable and reproducible clinical decisions.
대기 중 VOC 측정의 총괄 불확도 평가 - 흡착/열 탈착/GC MS 방법을 대상으로
[Kisti 연계] 한국대기환경학회 한국대기환경학회 학술대회논문집 2005 pp.405-406
※ 협약을 통해 무료로 제공되는 자료로, 원문이용 방식은 연계기관의 정책을 따르고 있습니다.
0개의 논문이 장바구니에 담겼습니다.
선택하신 파일을 압축중입니다.
잠시만 기다려 주십시오.