Purpose: This study aimed to assess the effect of build angle on the trueness of the internal and marginal areas of digital light processing–printed anterior zirconia cores. Methods: A prepared maxillary central incisor was scanned, and a core was designed using the dental computer-aided design (CAD) software. The core was positioned at build angles of 30°, 60°, and 90°. A 90° build angle was defined as the core’s long axis being perpendicular to the platform. After printing, washing, debinding, and sintering processes were performed (n=10 per group). For trueness evaluation, the printed cores were scanned and superimposed onto the reference CAD data, while the root mean square (RMS) values were measured. Statistical analysis was performed using one-way ANOVA and Tukey’s HSD test. Results: In the internal segment, the 30° group (57.38±7.93 μm) showed significantly higher RMS values than the 60° (39.59±3.41 μm) and 90° (36.71±7.60 μm) groups (p<0.001), whereas no significant difference was observed between the 60° and 90° groups. Similarly, in the marginal segment, the 30° group (61.83±8.13 μm) showed significantly higher RMS values than the 60° (43.19±3.36 μm) and 90° (40.51±8.77 μm) groups (p<0.001), whereas no significant difference was observed between the 60° and 90° groups. Conclusion: Due to the limitations of this in vitro study, the 60° and 90° build angles showed lower RMS values than the 30° build angle in both the internal and marginal areas. Among the tested conditions, the 90° build angle showed the lowest mean RMS values.

목차

Abstract
INTRODUCTION
MATERIALS AND METHODS
1. 연구설계
2. 시편 제작
3. 진실도 측정
4. 통계 분석
RESULTS
DISCUSSION
CONCLUSIONS
FUNDING
ACKNOWLEDGEMENTS
CONFLICT OF INTEREST
ORCID
REFERENCES

저자

  • 이주희 [ Juhee Lee | 대전보건대학교 치기공과 ]
  • 이하빈 [ Habin Lee | 연성대학교 치기공과 ] Corresponding Author

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한치과기공학회 [The Korean Academy Of Dental Technology]
  • 설립연도
    1979
  • 분야
    의약학>치의학
  • 소개
    본 학회는 치과기공에 관한 모든 분야의 연구와 회무를 총괄하기 위하여 세분화된 분과학회의 회원 상호간 학술교류와 정보를 수집하고, 보수교육 및 학술대회 준비, 진행과 학회지 발간등의 업무를 효율적으로 수행함을 목적으로 한다.

간행물

  • 간행물명
    대한치과기공학회지 [THE JOURNAL OF KOREAN ACADEMY OF DENTAL TECHNOLOGY]
  • 간기
    계간
  • pISSN
    1229-3954
  • eISSN
    2288-5218
  • 수록기간
    1979~2026
  • 등재여부
    KCI 등재
  • 십진분류
    KDC 515 DDC 617

이 권호 내 다른 논문 / 대한치과기공학회지 Vol.48 No.3

    피인용수 : 0건 (자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장