Sesame dregs pose a potential fire hazard due to their tendency to self-heat under specific conditions. This study investigates the self-heating characteristics of sesame dregs at 100℃, 120℃, 140℃, 160℃, 180℃, and 200℃ using a custom-built simulation apparatus. Self-heating refers to the process in which a material produces heat on its own, without any external heat sources. This phenomenon affects the thermal behavior of biomass residues such as sesame dregs, particularly under elevated temperatures and confined storage conditions. While inconsequential thermal activity was observed at lower temperatures, significant self-heating behavior characterized by internal temperature rise, swelling, darkening, and thermal degradation was observed at the temperature of 160℃, 180℃, and 200℃. Results highlight that environmental factors such as moisture, compaction, and limited airflow can substantially affect self-heating behavior. Furthermore, the findings suggest that standard UNRTG may not comprehensively represent the self-heating potential of sesame dregs. These findings emphasize the need for more comprehensive assessment approaches to improve the accuracy of fire risk assessments and develop efficient mitigation strategies.

목차

ABSTRACT
Introduction
Theoretical Background
Self-heating and Spontaneous Ignition
Temperature-dependent Reaction Kinetics and the Arrhenius Concept
Existing Self-heating Test Methods and Evaluation Criteria
UNRTG Self-heating Test
Thermal Analysis and Complementary Experimental Approaches
Limitations of Current Evaluation Methods and Implications for This Study
Methods and Materials
Samples Collection and Preparation
Test Machine
Test Method
Results and Discussion
Temperature Evolution under UNRTG Evaluation Conditions (100–140℃)
Onset and Progression of Self-heating at Extended Temperatures (160–200℃)
Conclusion
Acknowledgements
References

저자

  • A Young Choi [ National Fire Research Institute ] The 1st Author
  • Heethawakage Sasanka Kavinda Seram [ Dept. of Fire & Disaster Prevention Engineering, Changshin University ] Corresponding Author
  • Ki-Hun Nam [ Dept. of Fire & Disaster Prevention, Inje University ]
  • Yoo Youl Choi [ National Fire Research Institute ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    위기관리 이론과 실천 [Crisis and Emergency Management: Theory and Praxis]
  • 설립연도
    2005
  • 분야
    사회과학>행정학
  • 소개
    위기관리 이론과 실천(Crisis and Emergency Management: Theory and Praxis; CEM-TP)은 위기관리에 관한 제 학문분야간 협동적 연구 공동체(Research Network)로서 전통적 안보 위기, 재난 위기(자연재난, 인위재난), 국가핵심기반 위기 등에 관한 제학문적 연구를 촉진하고 제 학문분야 연구자간 협력의 토대를 구축하기 위하여 위기관리 이론과 실천 편집위원회 구성이 완료된 2005년 2월 14일에 설립되었다. 현재 위기관리 이론과 실천(CEM-TP)에 참여하고 있는 연구자들의 학문 분야는 행정학, 사회학, 정치외교학, 신문방송학, 사회복지학, 법학, 심리학, 정보학, 지리학, 경찰행정학, 소방행정학, 경호학, 토목공학, 건축학, 의학, 간호학, 보건학, 기상학, 안전공학, 전산학, 지역개발학 등이 있으며, 따라서 한국의 위기관리 연구를 가장 폭 넓게 반영하고 있는 연구 공동체라 할 수 있다. 위기관리 이론과 실천(CEM-TP)의 조직으로는 편집위원회가 있으며, 편집위원회가 본 연구 공동체를 대표하고 있다. 따라서 위기관리 이론과 실천의 각종 연구 및 출판 활동은 편집위원회가 맡고 있으며, 현재 편집위원회는 46명의 위원으로 구성되어 있다. 또한 편집위원회는 위기관리의 제학문적 연구를 촉진하고 연구자간 협력을 위한 학술지로 <한국위기관리논집>을 발행한다. 위기관리 이론과 실천(CEM-TP)의 회원은 개인회원과 기관회원으로 구분된다. 개인회원은 본 회의 설립 목적과 취지에 찬동하는 위기관리 연구자 및 실무자로 구성되고, 기관회원은 위기관리 연구 및 실무에 관련된 정부기관, 연구기관, 대학도서관 등으로 구성된다

간행물

  • 간행물명
    Journal of Safety and Crisis Management
  • 간기
    월간
  • pISSN
    2234-2214
  • 수록기간
    2011~2026
  • 십진분류
    KDC 350 DDC 351

이 권호 내 다른 논문 / Journal of Safety and Crisis Management Vol. 16 No. 3

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장