Gage R&R 분석을 통한 인상재 기반 비파괴 정밀측정의 산업현장 적용성에 대한 연구
A Study on the Industrial Applicability of Impression Material-Based Non-Destructive Precision Measurement Using Gage R&R Analysis
※ 기관로그인 시 무료 이용이 가능합니다.
※ 학술발표대회집, 워크숍 자료집 중 4페이지 이내 논문은 '요약'만 제공되는 경우가 있으니, 구매 전에 간행물명, 페이지 수 확인 부탁 드립니다.
4,000원
원문정보
초록
영어
This study evaluated the industrial applicability of a non-destructive measurement method based on impression materials for complex internal geometries. Using Hydrophilic Vinyl Polysiloxane impression material and a Mitutoyo optical projector, repeated measurements (total 60 data points) were taken on dovetail groove samples. A Gage R&R analysis showed %EV at 12.75%, %AV at 5.5%, and %GRR at 13.9%, indicating conditionally acceptable reliability according to AIAG criteria. The results confirm the method's practical potential for industrial use, with opportunities for repeatability improvement. Future integration with digital imaging and AI edge-detection technologies is expected to further enhance automated precision measurement capabilities.
목차
Abstract 1. 서론 2. 이론적 배경 및 선행연구 3. 실험 방법 3.1 시험편 및 장비 구성 3.2 측정절차 3.3 Gage R&R(평균범위법) 실험 설계 4. 실험 결과 및 고찰 4.1 반복성-측정기 변동(EV): 반복 4.2 재현성-측정자 변동(AV): 재현성 4.3 반복성&재현성(GRR): 반복성 및 재현성 4.4 부품 변동(PV): 부품 변동 4.5 총 변동(TV): 총 변동 4.6 %EV, %AV, %GRR 5. 결론 References