탄천 수질 모니터링 기반 합류식 하수관거 월류수(CSOs)의 유출 특성 분석 및 현행 설계 기준의 실증적 고찰
Analysis of Runoff Characteristics of Combined Sewer Overflows (CSOs) Based on Tancheon Water Quality Monitoring and an Empirical Study of Current Design Standards
The management of combined sewer overflows (CSOs) has emerged as a key urban challenge. The current 3Q design standard permits overflows assuming rainfall dilution, but its actual effectiveness requires evaluation. This study analyzed CSO runoff characteristics using five years (2020–2024) of real-time total phosphorus (T-P) and rainfall data from the Tancheon basin in S city. Results revealed that during the spring season, when less rainfall occurs, (March–May), a strong first flush effect led to highly concentrated discharges (up to 3.77 mg/L), exceeding the effluent standard (0.5 mg/L) by up to 7.5 times. These findings clearly demonstrate the fundamental limitations of the current 3Q design standard.
한국어
도심지 불투수 면적의 증가로 인해 합류식 하수관거 월류수(CSOs)의 관리가 핵심 과제로 대두되고 있다. 현행 합류식하수관거의 설계기준(3Q)은 우천 시 다량의 빗물에 의한 오염물질 희석을 전제로 월류를 허용하고 있으나, 실제 하천의오염을 제어하고 있는지 검토가 요구된다. 본 연구는 S시 탄천 유수지의 최근 5년간(2020~2024년) 실시간 총인(T-P) 모니터링 데이터와 강우량 데이터를 연계하여 강우 시 월류수의 유출 특성을 분석하였다. 연구 결과, 강우량이 적은봄철(3~5월)에 초기세척(First Flush) 효과가 강하게 발생하여 방류수 수질 기준(0.5 mg/L)을 최대 7.5배 상회하는 고농도오염(최대 3.77 mg/L)이 집중적으로 유출되었다. 이는 합류식 하수관거의 설계기준(3Q)의 문제점을 보여준다.
목차
요약 Abstract 1. 서론 2. 연구방법 2.1 탄천의 처리구역의 특성 및 데이터 수집 위치 2.2 탄천수질 및 강우량 데이터 수집 2.3 데이터 전처리 2.4 오염 발생 분류기준 및 추 2.5 통계 분석 및 시각화 3. 연구결과 3.1 실시간 수질 데이터의 초과 특성 분석 3.2 시간별 수질의 변동 특성 및 강우량 분석 3.3 계절별 오염 발생빈도 분석 3.4 총인(T-P)수치 데이터 분석 결과 4. 결론 사사 (Acknowledgement) References