Measurement of the significance of scattered dose exposure from a mobile C-Arm

첫 페이지 보기
  • 발행기관
    대한디지털의료영상학회 바로가기
  • 간행물
    대한디지털의료영상학회논문지 바로가기
  • 통권
    Volume 27 Number 2 (2025.08)바로가기
  • 페이지
    pp.49-53
  • 저자
    HongMoon Jung, Jae-Goo Sim
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A483306

※ 기관로그인 시 무료 이용이 가능합니다.
※ 학술발표대회집, 워크숍 자료집 중 4페이지 이내 논문은 '요약'만 제공되는 경우가 있으니, 구매 전에 간행물명, 페이지 수 확인 부탁 드립니다.

4,000원

원문정보

초록

영어
In modern society, as aging progresses rapidly, medical institutions related to the diagnosis and treatment of spine and joints are rapidly increasing. Accordingly, the distribution of mobile C-arms, which are essential for the treatment of bones and joints, is increasing in various medical institutions. Unlike the C-arm equipment used in existing operating rooms, mobile C-arm equipment is known to have relatively low radiation doses. However, mobile C-arms cannot be used without ignoring the safety of radiation exposure. This is because they have the output and performance to produce a certain amount of radiation and are also fluoroscopy equipment that can view anatomical images in real time. In this study, we measured the radiation scatter of mobile C-arm equipment by distance and studied at what distance the effect of the scatter can be minimized. As a result, the average forward scatter was measured to be 1.8 μSv/hr within 2 m of the mobile C-arm, and a perceptible radiation scatter dose was measured up to 4 m. However, beyond 4 m, the scatter dose was measured to be insignificant. Therefore, to avoid radiation scatter exposure from the mobile C-arm, a distance of more than 4 m should be maintained.

목차

Abstract
Ⅰ. Introduction
Ⅱ. Materials and Methods
1. Radiation dose measurement of mobile C-arm
2. Statistical processing
Ⅲ. results
Ⅳ. Discussion and Conclusion
Reference

키워드

Mobile C-arm Mobile C-arm Scatter radiation Mobile C-arm distance dose

저자

  • HongMoon Jung [ Department of Radiology, DaeGu Health College ] Corresponding Author
  • Jae-Goo Sim [ Department of Radiology, DaeGu Health College ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한디지털의료영상학회 [대한디지털의료영상학]
  • 설립연도
    1995
  • 분야
    의약학>방사선과학
  • 소개
    대한디지털의료영상학회는 디지털 영상 기술에 관한 연구와 실험 결과를 임상에 적용하여 영상의학 및 진단 방사선 기술 분야의 발전에 기여함을 목적으로 한다.

간행물

  • 간행물명
    대한디지털의료영상학회논문지 [Korean Journal of Digital Imaging in Medicine]
  • 간기
    연3회
  • pISSN
    1976-7641
  • 수록기간
    1995~2025
  • 십진분류
    KDC 510 DDC 610

이 권호 내 다른 논문 / 대한디지털의료영상학회논문지 Volume 27 Number 2

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장