Assesment of MRI and US of Swelling Thickness in Knee MCL Patients : Grade 2 MCL Result Study
Knee MCL에서 자기공명영상과 초음파의 Swelling 두께평가 : Grade 2 MCL Resut Study
The purpose of this study is to select the optimal diagnostic device according to the error change after measuring with magnetic resonance imaging and ultrasonic imaging diagnostic device in patients with Knee medial ligament injury. This study carried out a comparative analysis of US and MRI images, using Samsung Diagnostic US and GE MRI with a total of 15 patients over 30 and under 60 with Knee MCL patients, Grade 2, As a result of Pearson correlation analysis of sprain measurements, MCL swelling thickness was 5.10 ± 2.37 mm in US and 5.01 ± 2.40 mm in MRI, In conclusion, through this study, it was found that definite diagnosis could be made only by US in the diagnosis of patients with isolated injury of MCL.
한국어
본 연구의 목적은 무릅 내측측부인대 손상환자를 대상으로 자기공명영상과 초음파영상진단기기를 이용하여 측정한 후 오차변화에 따른 최적의 진단기기를 선택하고자 한다. 이에 본 연구는 삼성 진단용 초음파와 GE사의 MRI를 이용하 여 30세 이상 60세 미만인 Knee MCL 손상 환자 grade 2, Knee MCL 15명을 대상으로 초음파와 MRI 검사영상을 비교분석 하였다. Sprain 측정 수치를 Pearson 상관관계 분석 한 결과 MCL swelling 두께는 초음파에서 5.10 ± 2.37mm, MRI에서는 5.01 ± 2.40mm가 나왔다. 결론적으로 본 연구를 통해 MCL 단독 손상환자 진단 시 초음파 검사만으로 확진 가능함을 확인 할 수 있었다.
목차
Abstract Ⅰ. 서론 Ⅱ. 대상 및 방법 1. 초음파 2. 자기공명영상 3. 통계분석 Ⅲ. 결과 Ⅳ. 고찰 V. 결론 참고문헌 요약
키워드
무릅내측인대자기공명영상초음파Medial Collateral LigamentMRIUS
저자
Eun-Hoe Goo [ 구은회 | Department of Radiological Science, Cheongju University ]
Corresponding Author
Do-Yeon Won [ 원도연 | Department of Radiological Science, Daegu Health College ]
Jae-Eun Jung [ 정재은 | Department of Radiological Science, Daegu Health College ]