DCE 3D Breast MRI 검사 시 30 sec 이내에 혈류 역학적 정보에 대한 연구 : Experienced Reports
A study on Hemo-Dynamic information Within 30 seconds in DCE 3D Breast MRI : Experienced Reports

첫 페이지 보기
  • 발행기관
    대한디지털의료영상학회 바로가기
  • 간행물
    대한디지털의료영상학회논문지 바로가기
  • 통권
    Volume 16 Number 1 (2014.07)바로가기
  • 페이지
    pp.27-33
  • 저자
    구은회
  • 언어
    한국어(KOR)
  • URL
    https://www.earticle.net/Article/A483067

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

원문정보

초록

영어
The purpose of this study evaluated the hemo-dynamic information within 30 seconds clinically in 3D breast MRI. From January to March 2014, A total of 40 people were examined at 1.5 Tesla(Philips, Medical System, Achieva, The Netherlands) MRI equipments using 16 channel SENSE breast coil. The imaging parameters on vibrant are fellow as: TR/TE/FA°/Matrix size/Slice thickness/Slab(5 ms/2 ms/10°/180x139x2 mm/80). This study used a Gadovist and injected it with injection speed of 4 ml /sec by auto injector with 15 ml saline flushing. Firstly, for the delay time study, it divided three different delay time from immediately, 20 seconds, and 30 seconds. In quantitative analysis, the ROI signal intensities of tumor and surrounding tissues were measured retrospectively. In qualitative analysis, the image quality was scored from 1 to 5 point by one experienced radiological technologists as a visual test. The significance level of each delay time was evaluated with a one-way ANOVA(p<0.05). In the visual test, score levels on 30 seconds delay time was a little bit higher than others(p<0.05). The signal intensity of the tumor were 1445 ± 360, 1410 ± 320, 1510 ± 415 on immediately, 20 seconds, and 30 seconds and score levels were 4.18 ± 0.85, 3.54 ± 0.94, 4.45 ± 0.74(p<0.05). The data on immediate images showed better results than that others(p<0.05). Conclusively, Although it has been high scored in 30sec delay time for visual test in order to avoid failure in 20second, 30seconds delay time after contrast media administration, we recommend that the DCE 3D breast MRI commence immediately

목차

Abstract
Ⅰ. 서론
Ⅱ. 대상 및 방법
1. 대상
2. 방법
Ⅲ. 결과
1. 제작기구 전후의 시간 비교
Ⅳ. 고찰
Ⅴ. 결론
참고문헌

키워드

Vibrant Dynamic Contrast Enhancement Breast MRI

저자

  • 구은회 [ Eun-Hoe Goo | 청주대학교 방사선학과 ] Corresponding Author

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한디지털의료영상학회 [대한디지털의료영상학]
  • 설립연도
    1995
  • 분야
    의약학>방사선과학
  • 소개
    대한디지털의료영상학회는 디지털 영상 기술에 관한 연구와 실험 결과를 임상에 적용하여 영상의학 및 진단 방사선 기술 분야의 발전에 기여함을 목적으로 한다.

간행물

  • 간행물명
    대한디지털의료영상학회논문지 [Korean Journal of Digital Imaging in Medicine]
  • 간기
    연3회
  • pISSN
    1976-7641
  • 수록기간
    1995~2025
  • 십진분류
    KDC 510 DDC 610

이 권호 내 다른 논문 / 대한디지털의료영상학회논문지 Volume 16 Number 1

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장