자동노출제어장치를 이용한 비정질 실리콘 평판형 검출기에서 격자의 조건에 따른 환자선량 변화와 촬영 거리의 변화가 검출기 획득선량에 미치는 영향
The Influence of the Change of Patient Radiation Exposure Dose Distribution on the Grid Condition and Detector Acquisition Dose on the Exposure Distance in the Use of Amorphous Silicon Thin Film Transistor Detector with AEC

첫 페이지 보기
  • 발행기관
    대한디지털의료영상학회 바로가기
  • 간행물
    대한디지털의료영상학회논문지 바로가기
  • 통권
    Volume 9 Number 2 (2007.12)바로가기
  • 페이지
    pp.23-30
  • 저자
    윤석환, 최준구, 한동균
  • 언어
    한국어(KOR)
  • URL
    https://www.earticle.net/Article/A482942

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

원문정보

초록

영어
This study attempts to propose an appropriate method of using digital medical imaging equipments, by studying the effects of automatic exposure control(AEC), grid ratio and the change of radiography distance on the patient dose and detector acquisition dose during the procedure of acquiring image through a digital medical imaging detector. The change of dose following the change of grid ratio's exposure and radiography distance was measured, by using an abdominal phantom organized with tissue equivalent materials in an amorphous silicon thin film transistor detecter installed with AEC. The case to use grid ratio 12 : 1, focal distance 180cm to radiography distance 110cm in AEC, the patient dose increased rather when we used grid ration 10 : 1, focal distance 110cm. When AEC was not used, the dose necessary for image acquisi仕on decreased as the grid ratio became higher and the distance became further, but detector acquisition dose was not reduced when it applied AEC. When purchasing digital medical imaging equipments, optional items such as AEC and grid shall be accurately selected to satisfy the use of the eqxiipments. Radiography errors made by radiation technologist and unnecessary patient dose can be reduced by selecting equipments with a radiography distance marker equipment when it did not apply AEC. These equipments can also be helpful in maintaining high imaging quality, one of the merits of digital detectors.

목차

Abstract
I. 서론
II. 연구대상 및 방법
1. 연구대상
2. 연구방법
III. 결과
IV. 고찰
V. 결론
참고문헌

키워드

Amorphous Silicon Thin Film Transistor Detecter Grids Focus distance AEC Patient dose

저자

  • 윤석환 [ Yoon, Seok-Hwan | 동남보건대학 방사선과 ]
  • 최준구 [ Choi, Jun-Gu | 건국대학교병원 영상의학과 ]
  • 한동균 [ Han, Dong-Kyoon | 을지대학교 보건과학대학 방사선학과 ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한디지털의료영상학회 [대한디지털의료영상학]
  • 설립연도
    1995
  • 분야
    의약학>방사선과학
  • 소개
    대한디지털의료영상학회는 디지털 영상 기술에 관한 연구와 실험 결과를 임상에 적용하여 영상의학 및 진단 방사선 기술 분야의 발전에 기여함을 목적으로 한다.

간행물

  • 간행물명
    대한디지털의료영상학회논문지 [Korean Journal of Digital Imaging in Medicine]
  • 간기
    연3회
  • pISSN
    1976-7641
  • 수록기간
    1995~2025
  • 십진분류
    KDC 510 DDC 610

이 권호 내 다른 논문 / 대한디지털의료영상학회논문지 Volume 9 Number 2

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장