Effects of Different Incident Direction on Organ-Absorbed Doses, Effective Doses, and Effective Dose Conversion Coefficients for Chest Radiography

첫 페이지 보기
  • 발행기관
    대한방사선방어학회 바로가기
  • 간행물
    방사선방어학회지 KCI 등재 SCOPUS 바로가기
  • 통권
    VOLUME 51 NUMBER 1 (2026.03)바로가기
  • 페이지
    pp.39-46
  • 저자
    Koji Ono, Yasuki Asada
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A482738

원문정보

초록

영어
Background: We aimed to evaluate the effects of different incident directions on organ-absorbed doses, effective doses, and effective dose conversion coefficients for chest radiography. Materials and Methods: We constructed an examination environment for chest radiography using a Monte Carlo simulation and estimated the organ-absorbed doses and effective doses for frontal anterior–posterior (AP), frontal posterior–anterior (PA), left lateral, and right lateral radiography. The effective dose conversion coefficients were calculated using the air kerma-area product. Results and Discussion: Some organs, such as the breast, showed more than a fivefold difference in the organ-absorbed dose between AP and PA radiography. In lateral radiography, there was a large difference in the organ-absorbed doses in the abdominal region. The effective dose was approximately 30% higher for AP radiography than for PA radiography. The effective dose conversion coefficients differed between AP and PA radiography. These findings are consistent with the anatomical arrangement of organs in the human body; nevertheless, they have not been explicitly reported in previous studies. Conclusion: It was suggested that using the PA direction of incidence in frontal radiography reduces the effective dose received by the patient. In addition, when estimating the effective dose using conversion coefficients, the estimated value may differ significantly due to differences in the direction of incidence, so the coefficients must be appropriately selected.

목차

ABSTRACT
Introduction
Materials and Methods
1. Setting up a Monte Carlo simulation
2. Estimation and Evaluation of Organ-Absorbed Dose
3. Estimation and Evaluation of Effective Dose and Effective Dose Conversion Coefficient
Results
1. Evaluation of Organ-Absorbed Dose
2. Evaluation of Effective Dose and Effective Dose Conversion Coefficient
Discussion
Conclusion
Article Information

키워드

Chest Radiography Organ-Absorbed Dose Effective Dose Effective Dose Conversion Coefficient Monte Carlo Simulation

저자

  • Koji Ono [ Department of Radiological Technology, Ichinomiya Municipal Hospital, Aichi, Japan; Graduate School of Health Sciences, Fujita Health University, Aichi, Japan ] Corresponding Author
  • Yasuki Asada [ Faculty of Radiological Technology, School of Medical Science, Fujita Health University, Aichi, Japan ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한방사선방어학회 [Korean Association For Radiation Protection]
  • 설립연도
    1975
  • 분야
    자연과학>기타자연과학
  • 소개
    회원 상호간의 협조와 친목을 도모함으로써 방사선방어에 관한 제반연구 및 발전에 이바지함을 물론 학술의 국제교류 및 국제학술단체와의 상호협력 증진에 기여함을 목적으로 하며, 이 목적을 달성하기 위하여 다음 각 호의 사업을 한다. 1. 방사선방어에 관한 학술연구발표회 및 강연회 등의 개최 2. 학회지 및 방사선방어에 관한 학술간행물의 발행 및 배포 3. 방사선방어에 관한 학술의 국제교류 및 협력 4. 방사선방어에 관한 국제학술자료의 조사, 수집 및 번역 5. 방사선방어에 관한 조사 및 연구용역 6. 회원의 연구활동을 위한 제반협조 7. 기타 본 학회의 목적 달성에 필요한 사항

간행물

  • 간행물명
    방사선방어학회지 [Journal of Radiation Protection and Research]
  • 간기
    계간
  • pISSN
    2508-1888
  • 수록기간
    1976~2026
  • 등재여부
    KCI 등재,SCOPUS
  • 십진분류
    KDC 559 DDC 629

이 권호 내 다른 논문 / 방사선방어학회지 VOLUME 51 NUMBER 1

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장