초록

영어
The aim of this study was to evaluate the analytical performance of a curved capillary configurations on a U-tube structure used in a tabletop fully automated blood viscometer. Precision was assessed using normal and abnormal quality control materials measured repeatedly over 20 days across shear rates of 1–1000 s⁻1. Correlation between straight and curved capillary configurations was evaluated. Sample stability was also assessed at shear rates of 1 s⁻1 and 300 s⁻1 over three consecutive days. The curved capillary system demonstrated robust precision, with total coefficients of variation decreasing with increasing shear rate. Strong correlations were observed between straight and curved capillary measurements across all shear rates. Passing– Bablok regression showed slopes close to unity and intercepts near zero, while Bland–Altman analysis revealed minimal bias without shear-dependent trends. Whole blood viscosity remained stable over three days at both low and high shear rates (all p > 0.98). The curved capillary–based U-tube configuration provides analytically equivalent and stable whole blood viscosity measurements compared with conventional straight capillary systems, supporting its suitability for fully automated blood viscometer.

목차

Abstract
1. Introduction
2. Materials and Methods
2.1 Precision evaluation of a curved capillary system
2.2 Method correlation between straight capillary and curved capillary configurations
2.3 Sample stability evaluation using a curved capillary configuration
3. Results
3.1 Precision performance of a curved capillary system
3.2 Correlation between straight capillary and curved capillary configurations
3.3 Sample stability evaluation
4. Discussion
5. Conclusion
Declaration of Interests
Acknowledgement
References

키워드

혈액점도 스캐닝모세관 굴곡미세채널 정밀도 자동혈액점도걔 Blood viscosity Scanning capillary Curved microchannel Precision Automated blood viscometer

저자

  • Dong Hwan Lee [ 이동환 | Department of Mechanical Design Engineering, College of Engineering, Jeonbuk National University ] Corresponding Author

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    한국기계항공기술학회(구 한국기계기술학회) [Korean Society of Mechanical Technology]
  • 설립연도
    1999
  • 분야
    공학>기계공학
  • 소개
    기계 관련 산업 분야에 관한 학술과 현장 적용 기술을 연구하고 교류하며, 이에 관련된 학문과 기술 발전 및 보급에 기여함으로써 과학과 기술의 진흥에 이바지함을 그 목적으로 한다.

간행물

  • 간행물명
    한국기계항공기술학회지(구 한국기계기술학회지) [Journal of the Korean Society of Mechanical and Aviation Technology ]
  • 간기
    격월간
  • pISSN
    1229-604X
  • eISSN
    2508-3805
  • 수록기간
    1999~2026
  • 등재여부
    KCI 등재
  • 십진분류
    KDC 550 DDC 620

이 권호 내 다른 논문 / 한국기계항공기술학회지(구 한국기계기술학회지) 제28권 제1호

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장