ICNGC 2025 The 11th International Conference on Next Generation Computing 2025 (2025.12)바로가기
페이지
pp.50-52
저자
Jiwon Hwang, Youngwoo Kim
언어
영어(ENG)
URL
https://www.earticle.net/Article/A478458
원문정보
초록
영어
Cone-Beam Computed Tomography (CBCT) plays a central role in Image-Guided Radiation Therapy (IGRT), but its relatively long acquisition time often leads to motion artifacts that reduce diagnostic quality. This work presents a framework for artifact correction based on residual learning within a conditional Denoising Diffusion Probabilistic Model (DDPM). In this setting, the model learns to predict the residual artifact component instead of the entire CT image. To encourage stable learning, a hybrid loss function incorporating L1 regularization on the predicted residual is introduced. The L1 term is intended to promote sparsity, guiding the model to focus on localized artifact regions while maintaining robustness against anatomical inconsistencies between CBCT and CT pairs. Experiments on paired CBCT-CT datasets showed improved quantitative and perceptual results compared to baseline diffusion and residual models, suggesting that the sparsity constraint may contribute to more reliable artifact suppression.
목차
Abstract I. INTRODUCTION II. METHODS A. Dataset and Preprocessing B. Model Architecture C. Hybrid Loss Function D. Experimental Design III. RESULTS A. Quantitative Evaluation B. Qualitative Analysis IV. DISCUSSION V. CONCLUSION ACKNOWLEDGMENT REFERENCES