Earticle

현재 위치 Home

Original Article

Dosimetric Evaluation for Various Applicator Setups with In-house Designed PMMA-Agar Phantom in Vaginal Cuff Brachytherapy

첫 페이지 보기
  • 발행기관
    대한방사선방어학회 바로가기
  • 간행물
    방사선방어학회지 KCI 등재 SCOPUS 바로가기
  • 통권
    VOLUME 50 NUMBER 3 (2025.09)바로가기
  • 페이지
    pp.171-182
  • 저자
    Saerom Sung, Hyemi Kim, Sunghyun Kim, Misun Kim, Hyejung Cha, Yeon Soo Yeom, Sei Hwan You, Chul Hee Min, Hyun Joon Choi
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A473600

원문정보

초록

영어
Background: Vaginal cuff brachytherapy after hysterectomy targets radiation to potential residual cancer cells. Our previous study proposed a three-ovoid applicator to improve dose coverage and stability over conventional applicators but was limited to two-dimensional plan comparisons. This study introduces a polymethyl methacrylate (PMMA)-Agar phantom for threedimensional (3D) dosimetric comparison of these applicators and verifies its applicability. Materials and Methods: Cylinder, two-ovoid, and three-ovoid applicators were compared. A PMMA frame (30 cm×20 cm×10 cm) with a central 10 cm diameter cavity for the Agar phantom was constructed. Using treatment plans delivering 3 Gy to a 5 mm thick bolus target, dose distributions were verified using Gafchromic EBT3 film (Ashland Inc.) and an Exradin A1SL thimble ionization chamber (Standard Imaging Inc.). Results and Discussion: Plan evaluations showed the three-ovoid applicator demonstrated improved dose uniformity and target coverage over conventional applicators. It yielded higher mean target doses (1.97 Gy vs. cylinder; 0.78 Gy vs. two-ovoid normal) and notably enhanced dose homogeneity, reducing a key uniformity index (D5 cm³/D99 Vol%) from 2.08 (cylinder) and 1.68 (two-ovoid normal) down to 1.61. These planned advantages were qualitatively supported by A1SL chamber and EBT3 film measurements showing dose distributions consistent with plans, experimentally verifying the three-ovoid’s dosimetric advantage using the PMMA-Agar phantom. Conclusion: In this study, we experimentally verified the three-ovoid applicator’s dosimetric advantage compared to the conventional applicators by using an in-house designed PMMAAgar phantom for vaginal cuff brachytherapy. We plan to improve the experimental 3D dose verification accuracy in the future, considering the more realistic patient’s internal organ structure using a 3D printing technique.

목차

ABSTRACT
Introduction
Materials and Methods
1. Applicators for Vaginal Cuff Brachytherapy
2. In-house Designed PMMA-Agar Phantom
3. Brachytherapy Planning
4. Dose Measurement
Results
1. Phantom Quality Evaluation
2. Plan Quality Evaluation for Various Applicators
3. Measured Dose Evaluation
Discussion
Conclusion
Article Information
References

저자

  • Saerom Sung [ Department of Radiation Convergence Engineering, Yonsei University, Wonju, Republic of Korea ]
  • Hyemi Kim [ Department of Radiological Science, Jeonju University, Jeonju, Republic of Korea ]
  • Sunghyun Kim [ Department of Radiation Oncology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea ]
  • Misun Kim [ Department of Radiation Oncology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea ]
  • Hyejung Cha [ Department of Radiation Oncology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea ]
  • Yeon Soo Yeom [ Department of Radiation Convergence Engineering, Yonsei University, Wonju, Republic of Korea ]
  • Sei Hwan You [ Department of Radiation Oncology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea ]
  • Chul Hee Min [ Department of Radiation Convergence Engineering, Yonsei University, Wonju, Republic of Korea ] Corresponding Author
  • Hyun Joon Choi [ Department of Radiation Oncology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea ] Corresponding Author

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한방사선방어학회 [Korean Association For Radiation Protection]
  • 설립연도
    1975
  • 분야
    자연과학>기타자연과학
  • 소개
    회원 상호간의 협조와 친목을 도모함으로써 방사선방어에 관한 제반연구 및 발전에 이바지함을 물론 학술의 국제교류 및 국제학술단체와의 상호협력 증진에 기여함을 목적으로 하며, 이 목적을 달성하기 위하여 다음 각 호의 사업을 한다. 1. 방사선방어에 관한 학술연구발표회 및 강연회 등의 개최 2. 학회지 및 방사선방어에 관한 학술간행물의 발행 및 배포 3. 방사선방어에 관한 학술의 국제교류 및 협력 4. 방사선방어에 관한 국제학술자료의 조사, 수집 및 번역 5. 방사선방어에 관한 조사 및 연구용역 6. 회원의 연구활동을 위한 제반협조 7. 기타 본 학회의 목적 달성에 필요한 사항

간행물

  • 간행물명
    방사선방어학회지 [Journal of Radiation Protection and Research]
  • 간기
    계간
  • pISSN
    2508-1888
  • 수록기간
    1976~2026
  • 등재여부
    KCI 등재,SCOPUS
  • 십진분류
    KDC 559 DDC 629

이 권호 내 다른 논문 / 방사선방어학회지 VOLUME 50 NUMBER 3

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장