Three sequentially installed DIWS system was employed to remove the exhaust of ferro-molybdenum from iron and steel industry. Depending on the adjustment of atomizer and collision sheets, the formation of scale was prohibited and the removal efficiency of SOx pollutants was influenced. SOx pollutants were gradually removed almost 90% by stages. When 20,000ppm of SOx was introduced into the system, the effluent was 7,000ppm and the removal was 65%. In stages, on the contrary, the effluent was decreased to just 10% and reached to 7% of SOx, where the total removal efficiency was 99.9%. When the pH was kept in the range of 4.0 to 6.0, SO2 was stably removed with the addition of MgSO4 chemical.
한국어
페로몰리(FeMo) 제조 공정에서 발생하는 대기오염 유발물질을 대상으로 미세기포가 발생되는 DIWS 장치를 이용하여 제거효율을 평가하였다. DIWS장치의 벤츄리와 아토마이저 위치 조절에 따라 반응조내 스케일 형성 억제와 탈황 효율에 영향을미치는 것으로 나타났다. 3개의 DIWS장치를 연속적으로 설치하여 20,000ppm의 SOx를 처리할 경우 단계적으로 90%이상제거되어 최종 제거율은 99.9%, 배출 농도는 7ppm으로 나타났다. 단위공정별 pH는 4.0∼6.0 범위였고, CaCO3 단독으로는급속하게 용액의 pH를 증가시키기 어려웠고, MgSO4를 사용한 결과 pH 조절이 원활한 것으로 관찰되었으며, 단위 공정용액의pH를 적절하게 유지해야지 SO2의 제거 효율을 일정하게 유지할 수 있었다. 연간 약 16,000톤의 페로몰리를 생산하는 실제처리장을 대상으로 85% 가동율을 고려할 경우, SOx 제거율 95%, NOx 제거율 50%, 분진 제거율 99%를 기대할 수 있을것으로 판단된다.
목차
요약 Abstract 1. 서론 2. 연구방법 2.1 공정 개요 2.2 연구 시설 2.3 DIWS 시설 3. 연구 결과 3.1 DIWS 장치 내 노즐 변경 3.2 DIWS 장치별 SOx 처리 3.3 공정 단계별 pH 변화 4. 결론 감사의 글 References