Earticle

현재 위치 Home

Original Article

Effect of repeated milling tool use in a dental CAD/CAM system on the marginal and internal fit of zirconia crowns

첫 페이지 보기
  • 발행기관
    대한치과기공학회 바로가기
  • 간행물
    대한치과기공학회지 KCI 등재 바로가기
  • 통권
    Vol.47 No.2 (2025.06)바로가기
  • 페이지
    pp.66-76
  • 저자
    Seong Tae Lee, KeunBaDa Son, Min-Jeong Kim, Ki-Whan Chang
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A468389

※ 기관로그인 시 무료 이용이 가능합니다.

4,200원

원문정보

초록

영어
Purpose: This study aimed to analyze and compare the marginal and internal fit of zirconia crowns fabricated using three types of milling tools with different durations of use (0, 50, and >100 hours). Methods: Zirconia crowns were designed using computer-aided design software, and the design files were extracted. Zirconia blocks (Luxen, Dentalmax) were milled using a five-axis milling machine (DWX-52D, Roland). Crowns were fabricated using unused milling tools, tools used for 50 clinical hours, and tools used for >100 clinical hours (n=12). The morphology of the milling tools was examined using a scanning electron microscope (VEGA, TESCAN). The marginal and internal fit of the fabricated zirconia crowns was evaluated using a D2000 scanner (3Shape) via the scanning method. Differences in fit among the crowns fabricated with tools of various usage durations were analyzed using one-way analysis of variance, with post-hoc analysis conducted through Tukey’s honest significant difference test (α=0.05). Results: Significant differences in zirconia crown fit were observed among the three tooluse groups (p<0.001). Milling tools used for >100 hours produced crowns with significantly lower marginal fit (p<0.05). Similarly, reproducibility in the 100-hour group was significantly reduced (p<0.05). Conclusion: Repeated clinical use of milling tools over extended periods may adversely affect the marginal fit and reproducibility of zirconia crowns.

목차

Abstract
INTRODUCTION
MATERIALS AND METHODS
1. Specimen preparation
2. Marginal and internal fit evaluation
3. Statistical analysis
RESULTS
1. Marginal and internal fit
2. Fabrication precision
3. Microscopic structural observation
DISCUSSION
CONCLUSIONS
FUNDING
ACKNOWLEDGEMENTS
CONFLICT OF INTEREST
ORCID
REFERENCES

키워드

Fit Internal Marginal Milling Tool

저자

  • Seong Tae Lee [ Department of Biohealth Convergence, Meister Master’s Course, Daegu Health College, Daegu, Korea ]
  • KeunBaDa Son [ Advanced Dental Device Development Institute (A3DI), School of Dentistry, Kyungpook National University Daegu, Korea ]
  • Min-Jeong Kim [ Department of Biohealth Convergence, Meister Master’s Course, Daegu Health College, Daegu, Korea ]
  • Ki-Whan Chang [ Department of Biohealth Convergence, Meister Master’s Course, Daegu Health College, Daegu, Korea ] Corresponding Author

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한치과기공학회 [The Korean Academy Of Dental Technology]
  • 설립연도
    1979
  • 분야
    의약학>치의학
  • 소개
    본 학회는 치과기공에 관한 모든 분야의 연구와 회무를 총괄하기 위하여 세분화된 분과학회의 회원 상호간 학술교류와 정보를 수집하고, 보수교육 및 학술대회 준비, 진행과 학회지 발간등의 업무를 효율적으로 수행함을 목적으로 한다.

간행물

  • 간행물명
    대한치과기공학회지 [THE JOURNAL OF KOREAN ACADEMY OF DENTAL TECHNOLOGY]
  • 간기
    계간
  • pISSN
    1229-3954
  • eISSN
    2288-5218
  • 수록기간
    1979~2026
  • 등재여부
    KCI 등재
  • 십진분류
    KDC 515 DDC 617

이 권호 내 다른 논문 / 대한치과기공학회지 Vol.47 No.2

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장