Earticle

현재 위치 Home

원저논문

반조절성교합기와 구강에서의 운동 오차에 대한 비교 연구
A study on the difference of movement between Semi adjustable articulator and Oral in vivo

첫 페이지 보기
  • 발행기관
    대한치과기공학회 바로가기
  • 간행물
    대한치과기공학회지 바로가기
  • 통권
    Vol.28 No.1 (2006.07)바로가기
  • 페이지
    pp.53-59
  • 저자
    문희경
  • 언어
    한국어(KOR)
  • URL
    https://www.earticle.net/Article/A46708

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

원문정보

초록

영어
The movement range on the semi adjustable articulator and the movement range in anoral were measured. And then I studied to analyze the gap. I got wax records by themovement on the semi adjustable articulator, the movement in an oral. I measured thedistance of the cusp tips that are close to the mesial direction and the distal direction, thebuccal direction and the lingual direction then I compared gaps.As I saw results on data, I knew that the semi adjustable articulator represented therange of mandibular movement restrictively. I could find the decisive contradiction thatthe sliding movement finished on the semi adjustable articulator although it did not finishin an oral. When the sliding movement does not reappear exactly, it brings a fatal failureto the dental prosthesis. In addition it is impossible that the semi adjustable articulatorrestores the movement in an oral because the lateral condyle inclination and thehorizontal condyle inclination are appeared to be straight. Therefore dental prosthesisseswere made by the semi adjustable articulator, they will interfere with a mastication.I have obtained the following results;1. The distance of sliding movement on the semi adjustable articulator showed shorter than the distance of sliding movement in oral. This means the increase of cusp inclinationof the dental prosthesis that was made on the semi adjustable articulator. Therefore,when the lateral movement occurs in oral, there is a possibility to become the prematureas the increase of cusp inclination. 2. The difference in the range of movement is considered as the gap that is madebecause the movement only can be occurred as straight in the semi adjustable articulator.3. When the dental technician understand mandibular movement and articulatordeficiencies, they can attain proficiency in use of the articulator and reduce the gap.

키워드

articulator semi adjustable articulator

저자

  • 문희경 [ Hee-Kyung Moon | 진주보건대학 치기공과 ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한치과기공학회 [The Korean Academy Of Dental Technology]
  • 설립연도
    1979
  • 분야
    의약학>치의학
  • 소개
    본 학회는 치과기공에 관한 모든 분야의 연구와 회무를 총괄하기 위하여 세분화된 분과학회의 회원 상호간 학술교류와 정보를 수집하고, 보수교육 및 학술대회 준비, 진행과 학회지 발간등의 업무를 효율적으로 수행함을 목적으로 한다.

간행물

  • 간행물명
    대한치과기공학회지 [THE JOURNAL OF KOREAN ACADEMY OF DENTAL TECHNOLOGY]
  • 간기
    계간
  • pISSN
    1229-3954
  • eISSN
    2288-5218
  • 수록기간
    1979~2026
  • 등재여부
    KCI 등재
  • 십진분류
    KDC 515 DDC 617

이 권호 내 다른 논문 / 대한치과기공학회지 Vol.28 No.1

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장