영어
Heat exchangers are the most effective devices for transferring heat energy in cryogenic fluid equipment. In a cryogenic thermodynamic venting system, the heat exchanger is immersed in a cryogenic liquid and operated to facilitate the heat exchange between the fluids within the heat exchanger. In this unique environment, heat is continuously introduced into the heat exchanger from the external surroundings. This study aimed to numerically investigate the impact of an external heat load on the performance of a heat exchanger. This study assessed the changes in the effectiveness of the heat exchanger when exposed to an external heat load. Specifically, the influence of a linear and constant external heat load along the length of the heat exchanger on its efficiency was analyzed. In addition, this study examined the effect of the external heat load on the effectiveness of a plate-type counterflow heat exchanger. The research findings indicated that the external heat load had a lesser impact on effectiveness reduction when it entered the heat exchanger as a cold fluid rather than a hot fluid. In addition, the decrease in effectiveness was less pronounced when the external heat load was concentrated in the high-temperature region as opposed to a uniform amount of external heat load entering the heat exchanger along its length. The effect of the external heat load based on the number of plates in a plate heat exchanger showed no correlation.

목차

Abstract
1. INTRODUCTION
2. NUMERICAL HEAT EXCHANGER MODEL
3. VALIDATION
4. EFFECT OF THE EXTERNAL HEAT LOAD PROFILE
5. EFFECT OF THE PLATE HEAT EXCHANGER CONFIGURATION AND EXTERNAL HEAT LOAD
6. EXAMPLE OF HEAT EXCHANGER OPERATION WITH THE EXTERNAL HEAT LOAD
7. SUMMARY & CONCLUSION
ACKNOWLEDGMENT
REFERENCES

키워드

cryogenic heat exchanger external heat load effectiveness thermodynamic vent system

저자

  • I. Yu [ Korea Aerospace Research Institute (KARI), Daejeon, Korea ]
  • S. Baek [ Korea Aerospace Research Institute (KARI), Daejeon, Korea/University of Science and Technology (UST), Daejeon, Korea ] Corresponding Author

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    한국초전도저온학회 (구 한국초전도저온공학회) [The Korean Society of Superconductivity and Cryogenics (KSSC)]
  • 설립연도
    1998
  • 분야
    공학>전기공학
  • 소개
    21세기 핵심기술인 초전도공학과 저온공학분야의 기술 수준을 향상시키고, 선진 외국의 관련 학회와의 국제 교류 뿐만 아니라 이 분야에서 산.학.연의 학술활동 및 기술교류의 구심점으로의 그 역할을 성실히 수행하고자 한다.

간행물

  • 간행물명
    한국초전도·저온논문지 (구 한국초전도저온공학회논문지) [Progress in Superconductivity and Cryogenics]
  • 간기
    계간
  • pISSN
    1229-3008
  • eISSN
    2287-6251
  • 수록기간
    1999~2026
  • 등재여부
    KCI 등재,SCOPUS
  • 십진분류
    KDC 427 DDC 537

이 권호 내 다른 논문 / 한국초전도·저온논문지 (구 한국초전도저온공학회논문지) Vol.27 No.1

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장