Earticle

현재 위치 Home

Review

Changes in the Diagnostic Reference Levels for Computed Tomography in Japan : A Literature Review to Guide Future Revisions

첫 페이지 보기
  • 발행기관
    대한방사선방어학회 바로가기
  • 간행물
    방사선방어학회지 KCI 등재 SCOPUS 바로가기
  • 통권
    VOLUME 50 NUMBER 1 (2025.03)바로가기
  • 페이지
    pp.15-28
  • 저자
    Teruo Ito
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A465206

원문정보

초록

영어
Radiation is widely used in medicine but has both benefits and risks. Three important points must be taken into account in the medical use of radiation: justification, optimization, and dose limits. However, dose limits are not established for patients when the potential benefit is greater than the exposure risk. The International Commission on Radiological Protection (ICRP) introduced the concept of diagnostic reference levels (DRLs) to optimize the protection of patients from medical radiation exposure for diagnostic and interventional procedures. The ICRP also recommended that these levels be reviewed periodically. This paper reviews the current status of DRLs in computed tomography (CT) in Japan and provides a foundation for future revisions. A literature review of the origins of DRLs in the field of CT imaging in Japan was conducted, along with a detailed discussion of the establishment of the 2020 DRLs by a project team of which the author was a member. Japan’s first medical exposure guidelines were presented by the Japan Association of Radiological Technologists in 2000. The Japan Network for Research and Information on Medical Exposures was set up in response to the so-called ‘Lancet paper incident’ in 2004, in which it was suggested that diagnostic X-rays could increase cancer incidence, as well as ICRP Publications 103 and 105, and the 2020 DRLs were established in response to ICRP Publication 135 and corresponding revisions of laws and regulations. The DRLs for CT of the brain are higher in Japan than in Western countries but are otherwise comparable. This report summarizes the historical background of setting DRLs in Japan based on a literature review and discusses the details of the 2020 DRLs in the field of CT. DRLs must be updated periodically to keep pace with changes in social conditions and advances in medical technology and equipment.

목차

ABSTRACT
Introduction
Materials and Methods
1. First Medical Exposure Guidelines in Japan (1996–2005)
2. The ‘Lancet Paper Incident’ (2004)
3. J-RIME (2010)
4. 2015 DRLs in Japan (2013–2017)
5. 2020 DRLs in Japan (2017–2023)
6. Toward Updating DRLs (2023–)
Results and Discussion
1. First Medical Exposure Guidelines in Japan (1996–2005)
2. The ‘Lancet Paper Incident’ (2004)
3. J-RIME (2010)
4. 2015 DRLs in Japan (2013–2017)
5. 2020 DRLs in Japan (2017–2023)
6. Toward Updating DRLs (2023–)
Conclusion
Article Information
References

키워드

Diagnostic Reference Level Radiation Exposure Computed Tomography Computed Tomography Dose Index Dose Length Product

저자

  • Teruo Ito [ Department of Radiology, Toho University Sakura Medical Center, Sakura, Japan ] Corresponding Author

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한방사선방어학회 [Korean Association For Radiation Protection]
  • 설립연도
    1975
  • 분야
    자연과학>기타자연과학
  • 소개
    회원 상호간의 협조와 친목을 도모함으로써 방사선방어에 관한 제반연구 및 발전에 이바지함을 물론 학술의 국제교류 및 국제학술단체와의 상호협력 증진에 기여함을 목적으로 하며, 이 목적을 달성하기 위하여 다음 각 호의 사업을 한다. 1. 방사선방어에 관한 학술연구발표회 및 강연회 등의 개최 2. 학회지 및 방사선방어에 관한 학술간행물의 발행 및 배포 3. 방사선방어에 관한 학술의 국제교류 및 협력 4. 방사선방어에 관한 국제학술자료의 조사, 수집 및 번역 5. 방사선방어에 관한 조사 및 연구용역 6. 회원의 연구활동을 위한 제반협조 7. 기타 본 학회의 목적 달성에 필요한 사항

간행물

  • 간행물명
    방사선방어학회지 [Journal of Radiation Protection and Research]
  • 간기
    계간
  • pISSN
    2508-1888
  • 수록기간
    1976~2026
  • 등재여부
    KCI 등재,SCOPUS
  • 십진분류
    KDC 559 DDC 629

이 권호 내 다른 논문 / 방사선방어학회지 VOLUME 50 NUMBER 1

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장