Earticle

현재 위치 Home

아파트의 지하주차장 연기제어특성에 따른 FDS분석
Analysis of FDS according to the Smoke Control Characteristics of Underground Parking Lot in Apartment

첫 페이지 보기
  • 발행기관
    대한안전경영과학회 바로가기
  • 간행물
    대한안전경영과학회지 KCI 등재 바로가기
  • 통권
    제26권 제4호 (2024.12)바로가기
  • 페이지
    pp.83-91
  • 저자
    김상식
  • 언어
    한국어(KOR)
  • URL
    https://www.earticle.net/Article/A460159

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

원문정보

초록

영어
This study compares and analyzes the discharge status of smoke according to the method of installing a mobile blower in the event of a fire in an underground parking lot of an apartment using an evacuation simulation. An evacuation simulation was conducted on the situation in which the discharge of smoke in the event of a fire was discharged using a mobile blower to extinguish the smoke in the event of a fire by focusing on the part without smoke facilities in the underground parking lot. The results derived through experiments on the amount of smoke discharged using the natural exhaust method and the mobile blower in the underground parking lot are as follows. (1) In the event of a fire in an underground parking lot, the PPV (positive pressure ventilation) method, which has been mainly used in the field, should be used in a limited way. It can be an effective method if the exhaust port corresponding to the amount of the blower and the smoke exhaust is located nearby, or if the capacity of the apartment ventilation fan is designed to meet the 18CMH/㎡ of the National Fire Protection Association (NFPA) 88A or the 27CMH/㎡ standard standard for performance-oriented design evaluation and operation such as fire fighting facilities of the National Fire Protection Association (NFPA) 88A. (2) In the case of the additional mixing method (PPV+NPV) performed in the FDS experiment, smoke emissions increased by 5.1% compared to the NPV single method, and increased by 24.4% compared to the PPV single method.

목차

Abstract
1. 서론
2. 본론
2.1 시설개요
2.2 입력값
2.3 시나리오의 구성
3. 결과 및 분석
3.1 가시도
3.2 연기 배출량
4. 결론
5. References

키워드

Apartment Underground parking lot Underground space Smoke discharge Smoke removal facilities

저자

  • 김상식 [ Sangsig Kim | 우석대학교 소방행정학과 교수 ] Corresponding Author

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한안전경영과학회 [Korea Safety Management & Science]
  • 설립연도
    1999
  • 분야
    공학>안전공학
  • 소개
    안전경영에 관한 학문과 기술을 발전,보급,응용하여 안전기술 및 관리기술의 진흥에 공헌하며, 재해예방을 통한 안전사회의 구현을 그 목적으로 함.

간행물

  • 간행물명
    대한안전경영과학회지 [Journal of Korea Safety Management & Science]
  • 간기
    계간
  • pISSN
    1229-6783
  • eISSN
    2288-1484
  • 수록기간
    1999~2025
  • 십진분류
    KDC 530 DDC 620

이 권호 내 다른 논문 / 대한안전경영과학회지 제26권 제4호

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장