Analysis of Radiation Exposure Dose according to Location Change during Radiation Irradiation

첫 페이지 보기
  • 발행기관
    국제문화기술진흥원 바로가기
  • 간행물
    International Journal of Advanced Culture Technology(IJACT) KCI 등재 바로가기
  • 통권
    Volume 12 Number 2 (2024.06)바로가기
  • 페이지
    pp.368-374
  • 저자
    Chang-Ho Cho, Jeong-Lae Kim
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A452038

※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.

원문정보

초록

영어
During an X-ray examination, the beam of radiation is dispersed in many directions. We believe that managing radiation dose is about providing transparency to users and patients in the accurate investigation and analysis of radiation dose. The purpose of measuring the radiation dose as a function of location is to ensure that medical personnel using the equipment or participating in the operating room are minimally harmed by the different radiation doses depending on their location. Four mobile diagnostic X-ray units were used to analyze the radiation dose depending on the spatial location. The image intensifier and the flat panel detector type that receives the image analyzed the dose by angle to measure the distribution of the exposure dose by location. The radiation equipment used was composed of four units, and measuring devices were installed according to the location. The X-ray (C-arm) was measured by varying the position from 0 to 360 degrees, and the highest dose was measured at the center position based on the abdominal position, and the highest dose was measured at the 90° position for the head position when using the image intensifier equipment. The operator or medical staff can see that the radiation dose varies depending on the position of the diagnostic radiation generator. In the image intensifier and flat panel detector type that accepts images, the dose by angle was analyzed for the distribution of exposed dose by position, and the measurement method should be changed according to the provision of dose information that is different from the dose output from the equipment according to the position.

목차

Abstract
1. Introduction
2. Methods
2.1. Instruments
2.2. Radiation generators for diagnostic measurement equipment (4 C-arms in total)
2.3 Experimental Methods
3. Results
3.1. Verification of the average radiation dose difference by equipment
3.2. Verification of the average radiation dose difference by position (angle)
3.3. Exposure dose measurements by position for the entire equipment
3.4. Exposure dose measurements by position for the entire equipment and by equipment type
4. Discussion
5. Conclusion
References

저자

  • Chang-Ho Cho [ Department of Biomedical Engineering, Eulji University, Seongnam, 13135, Korea ]
  • Jeong-Lae Kim [ Prof. Department of Biomedical Engineering, Eulji University, Seongnam, 13135, Korea ] Corresponding Author

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    국제문화기술진흥원 [The International Promotion Agency of Culture Technology]
  • 설립연도
    2009
  • 분야
    공학>공학일반
  • 소개
    본 진흥원은 문화기술(Culture Technology) 관련 산·학·연·관으로 구성된 비영리 단체이다. 문화기술(CT)은 정보통신기술(ICT), 문화적 사고 기반의 예술, 인문학, 디자인, 사회과학기술이 접목된 신융합기술(New Convergence Technology, NCT)로 정의한다. 인간의 삶의 질을 향상시키고, 진보된 방향으로 변화시키고, 문화기술 관련 분야의 학술 및 기술의 발전과 진흥에 공헌하기 위하여, 제3조의 필요한 사업을 행함을 그 목적으로 한다.

간행물

  • 간행물명
    International Journal of Advanced Culture Technology(IJACT)
  • 간기
    계간
  • pISSN
    2288-7202
  • eISSN
    2288-7318
  • 수록기간
    2013~2025
  • 등재여부
    KCI 등재
  • 십진분류
    KDC 600 DDC 700

이 권호 내 다른 논문 / International Journal of Advanced Culture Technology(IJACT) Volume 12 Number 2

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장