Recently, the International Maritime Organization is strengthening regulations for ships operating in polar regions. Hence, insulated multi-core tubes as components for vessels operating in extreme cold need to be investigated in various aspects. Furthermore, the demand for research on electric propulsion vessels is also increasingly growing. Thus, to utilize a 4-core insulated multi-core tube with glass wool as insulation, which was previously developed for ships operating in polar regions, as a water-cooled electrical cable, this study conducted an experiment on the temperature change when water at normal temperature 25℃ was supplied as a coolant under the overcurrent varied from 10A to 25A. As a result, the temperature increase of the core in 10A condition was 3.3℃, but it increased to 13.05℃ in the 25A condition. This showed that a temperature difference of approximately 9.75℃ occurred according to the overcurrent load. However, the coolant inlet and outlet temperatures were relatively uniform around 1℃ in all conditions. This suggests that increasing the residence time by proper control of the coolant flow in the future could achieve a higher cooling effect.
목차
ABSTRACT 1.서론 2. 연구 방법 2.1 단열 다심관의 제조 2.2 전기 케이블의 과전류 정의 2.3 줄열(Joule heat)발생 2.4 과전류 조건에 따른 수냉각 실험 방법 3. 연구 결과 4. 결론 및 고찰 References
키워드
단열 다심관글라스울과전류전기 추진선국제해사기구Insulated multi core tubeGlass woolOver currentElectric propulsion shipIMO
저자
이태호 [ Lee Tae ho | 경상국립대학교 ]
First author
김명준 [ Myoungjun Kim | 군산대학교 ]
Corresponding Author