Analyzing electrical singularities using X-ray analysis equipment of fire investigation vehicles arrived to the fire site can be useful as it can quickly determine the source of ignition through arc mapping analysis at the site. In addition, in the case of non-destructive inspection using X-ray, melted material such as PVC is melted so that it cannot be disassembled, or fire ignited by LED elements with high risk of damage to the original, In the case of multi-socket, it is useful for determining the firing point, where tracking occurs at the connection part which is connected by the power lines. And secondary short-circuit marks are formed by flames. When evidence is collected and requested to an appraisal agency, the reliability of the collected evidence can be further increased by attaching the X-ray nondestructive test result before disassembly. It is very important to secure physical evidence that is the basis for identification for a comprehensive conclusion at the fire scene. In addition, it is important to detect electrical singularities immediately using the X-ray of the fire investigation analysis vehicle at the fire site and to link the analysis in the analysis room.
목차
Abstract 1. 서론 1.1 연구배경 1.2 연구의 필요성 및 목적 2. 이론연구 2.1 연구내용 및 방법 2.2 화재사례 분석 2.3 전선의 전기적 특이점 2.4 X-ray 기본원리 2.5 선행연구 검토 3. 화재재현 실험 3.1 실험 시료 제작 3.2 본 실험 4. 결론 4.1 연구 결과 4.2 화재 현장의 증거물 확보 절차의 제안 참고문헌
화재의 과학적 감식, 원인규명 및 예방을 위한 학문과 기술의 발전을 도모하고, 산, 학, 연, 정의 상호 교류를 통한 화재예방과 조사 및 감식의 전문화와 함께 소방관련 정책방향 발전에 공한하며, 회원 및 화재 관련 분야의 국.내외 인사들과의 정보 교류를 위하여 설립되었다.