Earticle

현재 위치 Home

Original Article

다양한 CAD/CAM 제조 방식으로 제작한 3본 고정성 임시 치과 보철물의 정확도 비교
Accuracy comparison of 3-unit fixed dental provisional prostheses fabricated by different CAD/CAM manufacturing methods

첫 페이지 보기
  • 발행기관
    대한치과기공학회 바로가기
  • 간행물
    대한치과기공학회지 KCI 등재 바로가기
  • 통권
    Vol.45 No.2 (2023.06)바로가기
  • 페이지
    pp.31-38
  • 저자
    이혁준, 이하빈, 노미준, 김지환
  • 언어
    한국어(KOR)
  • URL
    https://www.earticle.net/Article/A431657

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

원문정보

초록

영어
Purpose: This in vitro study aimed to compare the trueness of 3-unit fixed dental provisional prostheses (FDPs) fabricated by three different additive manufacturing and subtractive manufacturing procedures. Methods: A reference model with a maxillary left second premolar and the second molar prepped and the first molar missing was scanned for the fabrication of 3-unit FDPs. An anatomically shaped 3-unit FDP was designed on computer-aided design software. 10 FDPs were fabricated by subtractive (MI group) and additive manufacturing (stereolithography: SL group, digital light processing: DL group, liquid crystal displays: LC group) methods, respectively (N=40). All FDPs were scanned and exported to the standard triangulated language file. A three-dimensional analysis program measured the discrepancy of the internal, margin, and pontic base area. As for the comparison among manufacturing procedures, the Kruskal–Wallis test and the Mann–Whitney test with Bonferroni correction were evaluated statistically. Results: Regarding the internal area, the root mean square (RMS) value of the 3-unit FDPs was the lowest in the MI group (31.79±6.39 μm) and the highest in the SL group (69.34±29.88 μm; p=0.001). In the marginal area, those of the 3-unit FDPs were the lowest in the LC group (25.39±4.36 μm) and the highest in the SL group (48.94±18.98 μm; p=0.001). In the pontic base area, those of the 3-unit FDPs were the lowest in the LC group (8.72±2.74 μm) and the highest in the DL group (20.75±2.03 μm; p=0.001). Conclusion: A statistically significant difference was observed in the RMS mean values of all the groups. However, in comparison to the subtractive manufacturing method, all measurement areas of 3-unit FDPs fabricated by three different additive manufacturing methods are within a clinically acceptable range.

목차

Abstract
INTRODUCTION
MATERIALS AND METHODS
1. 실험 모형 선택 및 시편 디자인
2. 시편 제작
3. 3D 중첩 및 통계분석
RESULTS
DISCUSSION
CONCLUSIONS
FUNDING
ACKNOWLEDGEMENTS
CONFLICT OF INTEREST
ORCID
REFERENCES

키워드

Three-unit bridge Additive manufacturing Computer-aided design Computeraided manufacturing Liquid crystal displays printer Subtractive manufacturing

저자

  • 이혁준 [ Hyuk-Joon Lee | 고려대학교 일반대학원 보건과학과 치의기공학전공, 고려대학교 4단계 BK21 러닝헬스시스템융합사업단 ]
  • 이하빈 [ Ha-Bin Lee | 고려대학교 일반대학원 보건과학과 치의기공학전공, 고려대학교 4단계 BK21 러닝헬스시스템융합사업단 ]
  • 노미준 [ Mi-Jun Noh | 고려대학교 일반대학원 보건과학과 치의기공학전공, 고려대학교 4단계 BK21 러닝헬스시스템융합사업단 ]
  • 김지환 [ Ji-Hwan Kim | 고려대학교 일반대학원 보건과학과 치의기공학전공, 고려대학교 4단계 BK21 러닝헬스시스템융합사업단 ] Corresponding Author

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한치과기공학회 [The Korean Academy Of Dental Technology]
  • 설립연도
    1979
  • 분야
    의약학>치의학
  • 소개
    본 학회는 치과기공에 관한 모든 분야의 연구와 회무를 총괄하기 위하여 세분화된 분과학회의 회원 상호간 학술교류와 정보를 수집하고, 보수교육 및 학술대회 준비, 진행과 학회지 발간등의 업무를 효율적으로 수행함을 목적으로 한다.

간행물

  • 간행물명
    대한치과기공학회지 [THE JOURNAL OF KOREAN ACADEMY OF DENTAL TECHNOLOGY]
  • 간기
    계간
  • pISSN
    1229-3954
  • eISSN
    2288-5218
  • 수록기간
    1979~2026
  • 등재여부
    KCI 등재
  • 십진분류
    KDC 515 DDC 617

이 권호 내 다른 논문 / 대한치과기공학회지 Vol.45 No.2

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장