The compressor of a refrigerator accounts for approximately 60-80% of the total energy consumption necessary for the refrigeration cycle. This study investigates the implementation of a pre-compression system featuring a vibrating nozzle, with the goal of enhancing the efficiency of a linear compressor. By utilizing this pre-compression system, the cooling capacity and efficiency of the compressor are expected to improve. The numerical results show that the pre-compression system leads to an improvement of approximately 1.7% in cooling capacity compared to the baseline model. Furthermore, an increase of approximately 0.1 in EER was observed, confirming the feasibility of incorporating a pre-compression system with a vibrating nozzle.
목차