Earticle

현재 위치 Home

Original Research

Determination of Scattered Radiation to the Thyroid Gland in Dental Cone Beam Computed Tomography

첫 페이지 보기
  • 발행기관
    대한방사선방어학회 바로가기
  • 간행물
    방사선방어학회지 KCI 등재 SCOPUS 바로가기
  • 통권
    VOLUME 48 NUMBER 1 (2023.03)바로가기
  • 페이지
    pp.15-19
  • 저자
    Wilson Hrangkhawl, Winniecia Dkhar, T. S. Madhavan, S. Sharath, R. Vineetha, Yogesh Chhaparwal
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A427223

원문정보

초록

영어
Background: Cone beam computed tomography (CBCT) is a specialized medical equipment and plays a significant role in the diagnosis of oral and maxillofacial diseases and abnormalities; however, it is attributed to risk of exposure of ionizing radiation. The aim of the study was to estimate and determine the amount of scattered radiation dose to the thyroid gland in dental CBCT during maxilla and mandible scan. Materials and Methods: The average scattered radiation dose for i-CAT 17–19 Platinum CBCT (Imaging Sciences International) was measured using a Multi-O-Meter (Unfors Instruments), placed at the patient’s neck on the skin surface of the thyroid cartilage, with an exposure parameter of 120 kVp and 37.07 mAs. The surface entrance dose was noted using the Multi-OMeter, which was placed at the time of the scan at the level of the thyroid gland on the anterior surface of the neck. Results and Discussion: The surface entrance dose to the thyroid from both jaws scans was 191.491±78.486 μGy for 0.25 mm voxel and 26.9 seconds, and 153.670±74.041 μGy from the mandible scan, whereas from the maxilla scan the surface entrance dose was 5.259±10.691 μGy. Conclusion: The surface entrance doses to the thyroid gland from imaging of both the jaws, and also from imaging of the maxilla and mandible alone were within the threshold limit. The surface entrance dose and effective dose in CBCT were dependent on the exposure parameters (kVp and mAs), scan length, and field of view. To further reduce the radiation dose, care should be taken in selecting an appropriate protocol as well as the provision of providing shielding to the thyroid gland.

목차

ABSTRACT
Introduction
Materials and Methods
Results and Discussion
Conclusion
Conflict of Interest
Ethical Statement
Author Contribution
References

키워드

Cone Beam Computed Tomography Maxilla Mandible Scattered Radiation Dose Thyroid Gland

저자

  • Wilson Hrangkhawl [ Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, India ]
  • Winniecia Dkhar [ Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, India ] Corresponding author
  • T. S. Madhavan [ Department of Medical Imaging Technology, School of Allied Sciences, Jaipur National University, Jaipur, India ]
  • S. Sharath [ Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, India ]
  • R. Vineetha [ Department of Oral and Dental Radiology, Manipal College of Dental Sciences, Manipal Academy of Higher Education, Manipal, India ]
  • Yogesh Chhaparwal [ Department of Oral and Dental Radiology, Manipal College of Dental Sciences, Manipal Academy of Higher Education, Manipal, India ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한방사선방어학회 [Korean Association For Radiation Protection]
  • 설립연도
    1975
  • 분야
    자연과학>기타자연과학
  • 소개
    회원 상호간의 협조와 친목을 도모함으로써 방사선방어에 관한 제반연구 및 발전에 이바지함을 물론 학술의 국제교류 및 국제학술단체와의 상호협력 증진에 기여함을 목적으로 하며, 이 목적을 달성하기 위하여 다음 각 호의 사업을 한다. 1. 방사선방어에 관한 학술연구발표회 및 강연회 등의 개최 2. 학회지 및 방사선방어에 관한 학술간행물의 발행 및 배포 3. 방사선방어에 관한 학술의 국제교류 및 협력 4. 방사선방어에 관한 국제학술자료의 조사, 수집 및 번역 5. 방사선방어에 관한 조사 및 연구용역 6. 회원의 연구활동을 위한 제반협조 7. 기타 본 학회의 목적 달성에 필요한 사항

간행물

  • 간행물명
    방사선방어학회지 [Journal of Radiation Protection and Research]
  • 간기
    계간
  • pISSN
    2508-1888
  • 수록기간
    1976~2026
  • 등재여부
    KCI 등재,SCOPUS
  • 십진분류
    KDC 559 DDC 629

이 권호 내 다른 논문 / 방사선방어학회지 VOLUME 48 NUMBER 1

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장