In this study, to improve the performance of kitchen range hoods, a comparative analysis of air volume and noise is conducted using three ducts by changing shapes. It was found that the difference in air volume was caused by the pressure difference received by each shape. The noise data can be found to be no more than 60dB overall, except for the second tier of A-type. The difference when connecting the circular, square, and flexible ducts was judged to be due to some laboratory noise, and it was found that there was no difference.
목차
ABSTRACT 1. 서론 2. 기술개발 필요성 2.1 개발의 필요성 2.2 기술개발 목표 3. 실험 이론 및 실험 방법 3.1 실험 이론 3.2 덕트의 시작품 제작 3.3 레인지 후드 기계 선정 3.4 실험 방법 4. 실험결과 4.1 정압과 실험조건 적합성 판단 4.2 유속 실험 결과 4.3 소음 실험 결과 5. 결과 분석 5.1 유량 및 풍량 결과 분석 5.2 소음 결과 분석 6. 결론 References
키워드
원형 덕트사각 덕트주름 덕트레인지 후드유속소음Round ductSquare ductFlexible ductRange hoodsVelocity of flowSound
저자
이재준 [ Jae-Jun Lee | Member, Gangneung-Wonju National University ]
Corresponding Author
이원섭 [ Won-Seub Lee | Member, Professor, Indepartment of Mech-anical & Biomedical Engineering Gangneung-Wonju National University ]