Earticle

현재 위치 Home

Bio or medical Information Technology (BIT)

A Study on the Measurement of Respiratory Rate Using a Respirator Equipped with an Air Pressure Sensor

첫 페이지 보기
  • 발행기관
    국제인공지능학회(구 한국인터넷방송통신학회) 바로가기
  • 간행물
    The International Journal of Advanced Smart Convergence 바로가기
  • 통권
    Volume 11 Number 4 (2022.12)바로가기
  • 페이지
    pp.240-246
  • 저자
    Woochang Shin
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A423266

※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.

원문정보

초록

영어
In order to measure the respiratory rate, one of the major vital signs, many devices have been developed and related studies have been conducted. In particular, as the number of wearers of respirators increases in the COVID-19 pandemic situation, studies have been conducted to measure the respiratory rate of the wearer by attaching an electronic sensor to the respirator, but most of them are cases in which an air flow sensor or a microphone sensor is used. In this study, we design and develop a system that measures the respiratory rate of the wearer using an air pressure sensor in a respirator. Air pressure sensors are inexpensive and consume less power than the other sensors. In addition, since the amount of data required for calculation is small and the algorithm is simple, it is suitable for small-scale and low-power processing devices such as Arduino. We developed an algorithm to measure the respiratory rate of a respirator wearer by analysing air pressure change patterns. In addition, variables that can affect air pressure changes were selected, and experimental scenarios were designed according to the variables. According to the designed scenario, we collected air pressure data while the respirator wearer was breathing. The performance of the developed system was evaluated using the collected data.

목차

Abstract
1. INTRODUCTION
2. RELATED WORK
3. SYSTEM DEVELOPMENT AND EXPERIMENTAL SCENARIO DESIGN
3.1 Development of a Respirator system with an electronic air pressure sensor
3.2 Experimental Scenario Design
3.3 Pre-processing of air pressure sensor signal
3.4 Respiratory rate measurement algorithm
4. EXPERIMENTS
5. CONCLUSION
ACKNOWLEDGEMENT
REFERENCES

키워드

Respiration Rate Air Pressure Respirator Electronic Sensor ESP32 Vital Sign

저자

  • Woochang Shin [ Professor, Dept. of Computer Science, Seokyeong University, Korea ] Corresponding Author

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    국제인공지능학회(구 한국인터넷방송통신학회) [The International Association for Artificial Intelligence]
  • 설립연도
    2000
  • 분야
    공학>전자/정보통신공학
  • 소개
    인터넷방송, 인터넷 TV , 방송 통신 네트워크 및 관련 분야에 대한 국내는 물론 국제적인 학술, 기술의 진흥발전에 공헌하고 지식 정보화 사회에 기여하고자 한다.

간행물

  • 간행물명
    The International Journal of Advanced Smart Convergence
  • 간기
    계간
  • pISSN
    2288-2847
  • eISSN
    2288-2855
  • 수록기간
    2012~2025
  • 십진분류
    KDC 326 DDC 380

이 권호 내 다른 논문 / The International Journal of Advanced Smart Convergence Volume 11 Number 4

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장