※ 기관로그인 시 무료 이용이 가능합니다.
※ 학술발표대회집, 워크숍 자료집 중 4페이지 이내 논문은 '요약'만 제공되는 경우가 있으니, 구매 전에 간행물명, 페이지 수 확인 부탁 드립니다.
4,000원
원문정보
초록
영어
Two β=0.10 cryomodules are required for the China Accelerator Driven Subcritical System (C-ADS) injector II accelerator. Flow design is of great importance in the performance of cryomodules, including thermal design, flow distribution, pressure drop and so on. This paper will study convection heat transfer of helium and relation among the pipe diameter, mass flow rate and Reynolds number. Furthermore, the influence of flow geometries on pressure drop and flow distribution will also be done. It was found that the theoretical flow distribution were in good agreement with the experimental data.
목차
Abstract 1. INTRODUCTION 2. FLOW SCHEME OF THE CRYOMODULE 3. FLOW THERMAL DESIGN 4. FLOW DISTRIBUTION AND PRESSURE DROP 5. CRYOMODULE PERFORMANCE AND DISCUSSION 6. CONCLUSIONS REFERENCES
키워드
cryomoduleHeat transferFlow distributionPressure drop
저자
Yu-Qin WAN [ College of Petrochemical Engineering, Lanzhou University of Technology, Lanzhou 730050, China, Institute of Modern Physics, Chinese Academy of Science, Lanzhou 730000, China ]
Yan-Ning HAN [ Institute of Modern Physics, Chinese Academy of Science, Lanzhou 730000, China ]
Jun-Hui Zhang [ Institute of Modern Physics, Chinese Academy of Science, Lanzhou 730000, China ]
Chao Li [ College of Petrochemical Engineering, Lanzhou University of Technology, Lanzhou 730050, China ]
Corresponding Author