Earticle

현재 위치 Home

Original Research

Effects of Fully Filling Deep Electron/Hole Traps in Optically Stimulated Luminescence Dosimeters in the Kilovoltage Energy Range

첫 페이지 보기
  • 발행기관
    대한방사선방어학회 바로가기
  • 간행물
    방사선방어학회지 KCI 등재 SCOPUS 바로가기
  • 통권
    VOLUME 47 NUMBER 3 (2022.09)바로가기
  • 페이지
    pp.134-142
  • 저자
    Minsoo Chun, Hyeongmin Jin, Sung Young Lee, Ohyun Kwon, Chang Heon Choi, Jong Min Park, Jung-in Kim
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A418472

원문정보

초록

영어
Background: This study investigated the characteristics of optically stimulated luminescence dosimeters (OSLDs) with fully filled deep electron/hole traps in the kV energy ranges. Materials and Methods: The experimental group consisted of InLight nanoDots, whose deep electron/hole traps were fully filled with 5 kGy pre-irradiation (OSLDexp), whereas the non-preirradiated OSLDs were arranged as a control group (OSLDcont). Absorbed doses for 75, 80, 85, 90, 95, 100, and 105 kVp with 200 mA and 40 ms were measured and defined as the unit doses for each energy value. A bleaching device equipped with a 520-nm long-pass filter was used, and the strong beam mode was used to read out signal counts. The characteristics were investigated in terms of fading, dose sensitivities according to the accumulated doses, and dose linearity. Results and Discussion: In OSLDexp, the average normalized counts (sensitivities) were 12.7%, 14.0%, 15.0%, 10.2%, 18.0%, 17.9%, and 17.3% higher compared with those in OSLDcont for 75, 80, 90, 95, 100, and 105 kVp, respectively. The dose accumulation and bleaching time did not significantly alter the sensitivity, regardless of the filling of deep traps for all radiation qualities. Both OSLDexp and OSLDcont exhibited good linearity, by showing coefficients determination (R2) > 0.99. The OSL sensitivities can be increased by filling of deep electron/hole traps in the energy ranges between 75 and 105 kVp, and they exhibited no significant variations according to the bleaching time.

목차

ABSTRACT
Introduction
Materials and Methods
1. Half-Value Layer (HVL) Measurement and Reference Dosimetry
2. Optically Stimulated Luminescence (OSL) Dosimetry System
3. Experimental Setup
Results and Discussion
1. Absolute Dosimetry
2. First Time Bleaching for OSLDexp
3. Determination of the Optimal Bleaching Time
4. Fading Effect
5. Dose Sensitivity
6. Dose Linearity
Conclusion
Conflict of Interest
Acknowledgements
Author Contribution
References

키워드

OSL Dosimeters in kV Ranges Deep Electron/Hole Trap kGy Pre-irradiation Dose Sensitivity

저자

  • Minsoo Chun [ Department of Radiation Oncology, Chung-Ang University Gwang Myeong Hospital, Gyeonggi-do, Korea; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea ]
  • Hyeongmin Jin [ Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea; 4Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea ]
  • Sung Young Lee [ Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea ]
  • Ohyun Kwon [ Department of Medical Physics, University of Wisconsin, Madison, WI, USA ]
  • Chang Heon Choi [ Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea; Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea; Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea ]
  • Jong Min Park [ Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea; Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea; Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea; Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, Korea ]
  • Jung-in Kim [ Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea; Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea; Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea ] Corresponding Author

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한방사선방어학회 [Korean Association For Radiation Protection]
  • 설립연도
    1975
  • 분야
    자연과학>기타자연과학
  • 소개
    회원 상호간의 협조와 친목을 도모함으로써 방사선방어에 관한 제반연구 및 발전에 이바지함을 물론 학술의 국제교류 및 국제학술단체와의 상호협력 증진에 기여함을 목적으로 하며, 이 목적을 달성하기 위하여 다음 각 호의 사업을 한다. 1. 방사선방어에 관한 학술연구발표회 및 강연회 등의 개최 2. 학회지 및 방사선방어에 관한 학술간행물의 발행 및 배포 3. 방사선방어에 관한 학술의 국제교류 및 협력 4. 방사선방어에 관한 국제학술자료의 조사, 수집 및 번역 5. 방사선방어에 관한 조사 및 연구용역 6. 회원의 연구활동을 위한 제반협조 7. 기타 본 학회의 목적 달성에 필요한 사항

간행물

  • 간행물명
    방사선방어학회지 [Journal of Radiation Protection and Research]
  • 간기
    계간
  • pISSN
    2508-1888
  • 수록기간
    1976~2026
  • 등재여부
    KCI 등재,SCOPUS
  • 십진분류
    KDC 559 DDC 629

이 권호 내 다른 논문 / 방사선방어학회지 VOLUME 47 NUMBER 3

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장